OBJECTIVES: The main objective was to generate a GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis and to test its reliability. To this end, we assessed the validity, feasibility and applicability of ultrasound assessment of finger entheses to incorporate them into the scoring system. METHODS: The study consisted of a stepwise process. First, in cadaveric specimens, we identified enthesis sites of the fingers by ultrasound and gross anatomy, and then verified presence of entheseal tissue in histological samples. We then selected the entheses to be incorporated into a dactylitis scoring system through a Delphi consensus process among international experts. Next, we established and defined the ultrasound components of dactylitis and their scoring systems using Delphi methodology. Finally, we tested the interobserver and intraobserver reliability of the consensus- based scoring systemin patients with psoriatic dactylitis. RESULTS: 32 entheses were identified in cadaveric fingers. The presence of entheseal tissues was confirmed in all cadaveric samples. Of these, following the consensus process, 12 entheses were selected for inclusion in GLOUDAS. Ultrasound components of GLOUDAS agreed on through the Delphi process were synovitis, tenosynovitis, enthesitis, subcutaneous tissue inflammation and periextensor tendon inflammation. The scoring system for each component was also agreed on. Interobserver reliability was fair to good (κ 0.39-0.71) and intraobserver reliability good to excellent (κ 0.80-0.88) for dactylitis components. Interobserver and intraobserver agreement for the total B-mode and Doppler mode scores (sum of the scores of the individual abnormalities) were excellent (interobserver intraclass correlation coefficient (ICC) 0.98 for B-mode and 0.99 for Doppler mode; intraobserver ICC 0.98 for both modes). CONCLUSIONS: We have produced a consensus-driven ultrasound dactylitis scoring system that has shown acceptable interobserver reliability and excellent intraobserver reliability. Through anatomical knowledge, small entheses of the fingers were identified and histologically validated.
- MeSH
- delfská metoda MeSH
- dospělí MeSH
- entezopatie diagnostické zobrazování MeSH
- kloub prstu ruky * diagnostické zobrazování patologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mrtvola MeSH
- odchylka pozorovatele MeSH
- prsty ruky diagnostické zobrazování patologie MeSH
- psoriatická artritida * diagnostické zobrazování MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- studie proveditelnosti MeSH
- stupeň závažnosti nemoci * MeSH
- synovitida diagnostické zobrazování patologie MeSH
- tenosynovitida diagnostické zobrazování MeSH
- ultrasonografie * metody MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- validační studie MeSH
OBJECTIVE: To evaluate the intraobserver and interobserver reliability of the ultrasonographic (US) assessment of subtalar joint (STJ) synovitis in patients with rheumatoid arthritis (RA). METHODS: Following a Delphi process, 12 sonographers conducted an US reliability exercise on 10 RA patients with hindfoot pain. The anteromedial, posteromedial, and posterolateral STJ was assessed using B-mode and power Doppler (PD) techniques according to an agreed US protocol and using a 4-grade semiquantitative grading score for synovitis [synovial hypertrophy (SH) and signal] and a dichotomous score for the presence of joint effusion (JE). Intraobserver and interobserver reliability were computed by Cohen's and Light's κ. Weighted κ coefficients with absolute weighting were computed for B-mode and PD signal. RESULTS: Mean weighted Cohen's κ for SH, PD, and JE were 0.80 (95% CI 0.62-0.98), 0.61 (95% CI 0.48-0.73), and 0.52 (95% CI 0.36-0.67), respectively. Weighted Cohen's κ for SH, PD, and JE in the anteromedial, posteromedial, and posterolateral STJ were -0.04 to 0.79, 0.42-0.95, and 0.28-0.77; 0.31-1, -0.05 to 0.65, and -0.2 to 0.69; 0.66-1, 0.52-1, and 0.42-0.88, respectively. Weighted Light's κ for SH was 0.67 (95% CI 0.58-0.74), 0.46 (95% CI 0.35-0.59) for PD, and 0.16 (95% CI 0.08-0.27) for JE. Weighted Light's κ for SH, PD, and JE were 0.63 (95% CI 0.45-0.82), 0.33 (95% CI 0.19-0.42), and 0.09 (95% CI -0.01 to 0.19), for the anteromedial; 0.49 (95% CI 0.27-0.64), 0.35 (95% CI 0.27-0.4), and 0.04 (95% CI -0.06 to 0.1) for posteromedial; and 0.82 (95% CI 0.75-0.89), 0.66 (95% CI 0.56-0.8), and 0.18 (95% CI 0.04-0.34) for posterolateral STJ, respectively. CONCLUSION: Using a multisite assessment, US appears to be a reliable tool for assessing synovitis of STJ in RA.
- MeSH
- delfská metoda MeSH
- dospělí MeSH
- incidence MeSH
- konsensus MeSH
- lidé středního věku MeSH
- lidé MeSH
- reprodukovatelnost výsledků MeSH
- revmatoidní artritida patologie MeSH
- subtalární kloub diagnostické zobrazování patologie MeSH
- synovitida diagnostické zobrazování epidemiologie MeSH
- ultrasonografie dopplerovská metody normy MeSH
- výzkumný projekt MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
- systematický přehled MeSH
OBJECTIVE: To develop the first ultrasound scoring system of tendon damage in rheumatoid arthritis (RA) and assess its intraobserver and interobserver reliability. METHODS: We conducted a Delphi study on ultrasound-defined tendon damage and ultrasound scoring system of tendon damage in RA among 35 international rheumatologists with experience in musculoskeletal ultrasound. Twelve patients with RA were included and assessed twice by 12 rheumatologists-sonographers. Ultrasound examination for tendon damage in B mode of five wrist extensor compartments (extensor carpi radialis brevis and longus; extensor pollicis longus; extensor digitorum communis; extensor digiti minimi; extensor carpi ulnaris) and one ankle tendon (tibialis posterior) was performed blindly, independently and bilaterally in each patient. Intraobserver and interobserver reliability were calculated by κ coefficients. RESULTS: A three-grade semiquantitative scoring system was agreed for scoring tendon damage in B mode. The mean intraobserver reliability for tendon damage scoring was excellent (κ value 0.91). The mean interobserver reliability assessment showed good κ values (κ value 0.75). The most reliable were the extensor digiti minimi, the extensor carpi ulnaris, and the tibialis posterior tendons. An ultrasound reference image atlas of tenosynovitis and tendon damage was also developed. CONCLUSIONS: Ultrasound is a reproducible tool for evaluating tendon damage in RA. This study strongly supports a new reliable ultrasound scoring system for tendon damage.
- MeSH
- delfská metoda MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- odchylka pozorovatele MeSH
- poranění šlachy etiologie ultrasonografie MeSH
- reprodukovatelnost výsledků MeSH
- revmatoidní artritida komplikace ultrasonografie MeSH
- ruptura etiologie ultrasonografie MeSH
- senioři MeSH
- šlachy ultrasonografie MeSH
- stupeň závažnosti nemoci MeSH
- tenosynovitida etiologie ultrasonografie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- konsensus - konference MeSH
- práce podpořená grantem MeSH