- MeSH
- blokáda Tawarova raménka etiologie terapie MeSH
- elektrokardiografie MeSH
- funkce levé komory srdeční MeSH
- Hisův svazek * MeSH
- kardiomyopatie * etiologie terapie MeSH
- kardiostimulace umělá škodlivé účinky MeSH
- lidé MeSH
- srdeční komory MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Pulsed-field ablation (PFA) represents a new, nonthermal ablation energy for the ablation of atrial fibrillation (AF). Ablation energies producing thermal injury are associated with an inflammatory response, platelet activation, and coagulation activation. OBJECTIVES: This study aimed to compare the systemic response in patients undergoing pulmonary vein isolation (PVI) using pulsed-field and radiofrequency (RF) energy. METHODS: Patients with AF indicated for PVI were enrolled and randomly assigned to undergo PVI using RF (CARTO Smart Touch, Biosense Webster) or pulsed-field (Farapulse, Boston-Scientific) energy. Markers of myocardial damage (troponin I), inflammation (interleukin-6), coagulation (D-dimers, fibrin monomers, von Willebrand antigen and factor activity), and platelet activation (P-selectin, activated GpIIb/IIIa antigen) were measured before the procedure (T1), after trans-septal puncture (T2), after completing the ablation in the left atrium (T3), and 1 day after the procedure (T4). RESULTS: A total of 65 patients were enrolled in the pulsed-field ablation (n = 33) and RF ablation (n = 32) groups. Both groups were similar in baseline characteristics (age 60.5 ± 12.7 years vs 64.0 ± 10.7 years; paroxysmal AF: 60.6% vs 62.5% patients). Procedural and left atrial dwelling times were substantially shorter in the PFA group (55:09 ± 11:57 min vs 151:19 ± 41:25 min; P < 0.001; 36:00 ± 8:05 min vs 115:58 ± 36:49 min; P < 0.001). Peak troponin release was substantially higher in the PFA group (10,102 ng/L [IQR: 8,272-14,207 ng/L] vs 1,006 ng/L [IQR: 603-1,433ng/L]). Both procedures were associated with similar extents (>50%) of platelet and coagulation activation. The proinflammatory response 24 h after the procedure was slightly but nonsignificantly higher in the RF group. CONCLUSIONS: Despite 10 times more myocardial damage, pulsed-field ablation was associated with a similar degree of platelet/coagulation activation, and slightly lower inflammatory response. (The Effect of Pulsed-Field and Radiofrequency Ablation on Platelet, Coagulation and Inflammation; NCT05603637).
BACKGROUND: Hemolysis-related renal failure has been described after pulmonary vein isolation (PVI) with pulsed-field ablation (PFA). OBJECTIVES: This study sought to compare the potential for hemolysis during PVI with PFA vs radiofrequency ablation (RFA). METHODS: In consecutive patients, PVI was performed with PFA or RFA. Blood samples were drawn at baseline, immediately postablation, and 24 hours postablation. Using flow cytometry, the concentration of red blood cell microparticles (RBCμ) (fragments of damaged erythrocytes) in blood was assessed. Lactate dehydrogenase (LDH), haptoglobin, and indirect bilirubin were measured at baseline and 24 hours. RESULTS: Seventy patients (age: 64.7 ± 10.2 years; 47% women; 36 [51.4%] paroxysmal atrial fibrillation) were enrolled: 47 patients were in the PFA group (22 PVI-only and 36.4 ± 5.5 PFA applications; 25 PVI-plus, 67.3 ± 12.4 pulsed field energy applications), and 23 patients underwent RFA. Compared to baseline, the RBCμ concentration increased ∼12-fold postablation and returned to baseline by 24 hours in the PFA group (median: 70.8 [Q1-Q3: 51.8-102.5] vs 846.6 [Q1-Q3: 639.2-1,215.5] vs 59.3 [Q1-Q3: 42.9-86.5] RBCμ/μL, respectively; P < 0.001); this increase was greater with PVI-plus compared to PVI-only (P = 0.007). There was also a significant, albeit substantially smaller, periprocedural increase in RBCμ with RFA (77.7 [Q1-Q3: 39.2-92.0] vs 149.6 [Q1-Q3: 106.6-180.8] vs 89.0 [Q1-Q3: 61.2-123.4] RBCμ/μL, respectively; P < 0.001). At 24 hours with PFA, the concentration of LDH and indirect bilirubin increased, whereas haptoglobin decreased significantly (all P < 0.001). In contrast, with RFA, there were only smaller changes in LDH and haptoglobin concentrations (P = 0.03) and no change in bilirubin. CONCLUSIONS: PFA was associated with significant periprocedural hemolysis. With a number of 70 PFA lesions, the likelihood of significant renal injury is uncommon.
- MeSH
- fibrilace síní * chirurgie MeSH
- hemolýza * MeSH
- katetrizační ablace * škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- radiofrekvenční ablace škodlivé účinky metody MeSH
- senioři MeSH
- venae pulmonales chirurgie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
PURPOSE: Post-operative atrial fibrillation (PoAF) occurs in ~ 30% of patients after cardiac surgery. The etiology of PoAF is complex, but a disbalance in autonomic systems plays an important role. The goal of this study was to assess whether pre-operative heart rate variability analysis can predict the risk of PoAF. METHODS: Patients without a history of AF with an indication for cardiac surgery were included. Two-hour ECG recordings one day before surgery was used for the HRV analysis. Univariate and multivariate logistic regression, including all HRV parameters, their combination, and clinical variables, were calculated to find the best predictive model for post-operative AF. RESULTS: One hundred and thirty-seven patients (33 women) were enrolled in the study. PoAF occurred in 48 patients (35%, AF group); the remaining 89 patients were in the NoAF group. AF patients were significantly older (69.1 ± 8.6 vs. 63.4 ± 10.5 yrs., p = 0.002), and had higher CHA2DS2-VASc score (3 ± 1.4 vs. 2.5 ± 1.3, p = 0.01). In the multivariate regression model, parameters independently associated with higher risk of AF were pNN50, TINN, absolute power VLF, LF and HF, total power, SD2, and the Porta index. A combination of clinical variables with HRV parameters in the ROC analysis achieved an AUC of 0.86, a sensitivity of 0.95, and a specificity of 0.57 and was more effective in PoAF prediction than a combination of clinical variables alone. CONCLUSION: A combination of several HRV parameters is helpful in predicting the risk of PoAF. Attenuation of heart rate variability increases the risk for PoAF.
- MeSH
- fibrilace síní * diagnóza epidemiologie etiologie MeSH
- kardiochirurgické výkony * škodlivé účinky MeSH
- lidé MeSH
- pooperační komplikace diagnóza etiologie MeSH
- rizikové faktory MeSH
- ROC křivka MeSH
- srdeční frekvence fyziologie MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Biventricular pacing (Biv) and left bundle branch area pacing (LBBAP) are methods of cardiac resynchronization therapy (CRT). Currently, little is known about how they differ in terms of ventricular activation. This study compared ventricular activation patterns in left bundle branch block (LBBB) heart failure patients using an ultra-high-frequency electrocardiography (UHF-ECG). This was a retrospective analysis including 80 CRT patients from two centres. UHF-ECG data were obtained during LBBB, LBBAP, and Biv. Left bundle branch area pacing patients were divided into non-selective left bundle branch pacing (NSLBBP) or left ventricular septal pacing (LVSP) and into groups with V6 R-wave peak times (V6RWPT) < 90 ms and ≥ 90 ms. Calculated parameters were: e-DYS (time difference between the first and last activation in V1-V8 leads) and Vdmean (average of V1-V8 local depolarization durations). In LBBB patients (n = 80) indicated for CRT, spontaneous rhythms were compared with Biv (39) and LBBAP rhythms (64). Although both Biv and LBBAP significantly reduced QRS duration (QRSd) compared with LBBB (from 172 to 148 and 152 ms, respectively, both P < 0.001), the difference between them was not significant (P = 0.2). Left bundle branch area pacing led to shorter e-DYS (24 ms) than Biv (33 ms; P = 0.008) and shorter Vdmean (53 vs. 59 ms; P = 0.003). No differences in QRSd, e-DYS, or Vdmean were found between NSLBBP, LVSP, and LBBAP with paced V6RWPTs < 90 and ≥ 90 ms. Both Biv CRT and LBBAP significantly reduce ventricular dyssynchrony in CRT patients with LBBB. Left bundle branch area pacing is associated with more physiological ventricular activation.
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Right ventricular pacing (RVP) can result in pacing-induced cardiomyopathy (PICM). It is unknown whether specific biomarkers reflect differences between His bundle pacing (HBP) and RVP and predict a decrease in left ventricular function during RVP. AIMS: We aimed to compare the effect of HBP and RVP on the left ventricular ejection fraction (LVEF) and to study how they affect serum markers of collagen metabolism. METHODS: Ninety-two high-risk PICM patients were randomized to HBP or RVP groups. Their clinical characteristics, echocardiography, and serum levels of transforming growth factor β1 (TGF-β1), matrix metalloproteinase 9 (MMP-9), suppression of tumorigenicity 2 interleukin (ST2-IL), tissue inhibitor of metalloproteinase 1 (TIMP-1), and galectin 3 (Gal-3) were studied before pacemaker implantation and six months later. RESULTS: Fifty-three patients were randomized to the HBP group and 39 patients to the RVP group. HBP failed in 10 patients, who crossed over to the RVP group. Patients with RVP had significantly lower LVEF compared to HBP patients after six months of pacing (-5% and -4% in as-treated and intention-to-treat analysis, respectively). Levels of TGF-β1 after 6 months were lower in HBP than RVP patients (mean difference -6 ng/ml; P = 0.009) and preimplant Gal-3 and ST2-IL levels were higher in RVP patients, with a decline in LVEF ≥5% compared to those with a decline of <5% (mean difference 3 ng/ml and 8 ng/ml; P = 0.02 for both groups). CONCLUSION: In high-risk PICM patients, HBP was superior to RVP in providing more physiological ventricular function, as reflected by higher LVEF and lower levels of TGF-β1. In RVP patients, LVEF declined more in those with higher baseline Gal-3 and ST2-IL levels than in those with lower levels.
- MeSH
- biologické markery MeSH
- elektrokardiografie MeSH
- funkce levé komory srdeční * fyziologie MeSH
- Hisův svazek MeSH
- interleukin-1 receptor-like 1 protein MeSH
- kardiomyopatie * MeSH
- kardiostimulace umělá škodlivé účinky MeSH
- kolagen MeSH
- lidé MeSH
- tepový objem fyziologie MeSH
- tkáňový inhibitor metaloproteinasy 1 MeSH
- transformující růstový faktor beta1 MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
Mezioborová spolupráce především mezi pediatrem a pedikérkou u unguis incarnatus předchází zdlouhavým a opakujícím se recidivám zarůstající nehtové ploténky. Konzervativní a bezbolestnou cestou je využití různých typů nehtových špon, vypodkládání a tejpování valů. Chirurgická řešení, jako je plastika valů a nebo nehtové ploténky, částečná resekce či totální ablace, nejsou žádoucí. Včasná diagnostika a odborné ošetření nehtovou šponou je prevencí poškození lůžka a deformit článku prstu po častých operativních zásazích. Konzervativní přístup v ošetření umožňuje okamžitý návrat k běžnému životu.
Interdisciplinary cooperation especially between a paediatrician and a pedicurist in treating unguis incarnatus prevents protracted and repetitive relapses. A conservative and painless way is to use different types of nail support, tamponade and taping the lateral nail fold. Surgical solutions such as a lateral nail fold surgery, a nail plate partial resection or a total ablation are not desirable. Early diagnosis and professional treatment with a nail support interventions prevents nail bed damage and deformities of the finger joint after frequent surgeries. A conservative approach to treatment allows for an immediate return to normal life.
- Klíčová slova
- nehtová špona, plastika valů, vypodkládání nehtu,
- MeSH
- dítě MeSH
- lidé MeSH
- výsledek terapie MeSH
- zarostlé nehty * patologie terapie MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- kazuistiky MeSH
INTRODUCTION: We aimed to compare the acute differences in left ventricular (LV) function and mechanical synchrony during nonselective His bundle pacing (ns-HBP) versus selective His bundle pacing (s-HBP) using strain echocardiography. METHODS AND RESULTS: Consecutive patients with permanent His bundle pacing, in whom it was possible to obtain both s-HBP and ns-HBP, were studied in two centers. In each patient, echocardiography was performed sequentially during s-HBP and ns-HBP. Speckle-tracking echocardiography parameters were analyzed: Global longitudinal strain (GLS), the time delay between peak systolic strain in the basal septal and basal lateral segments (BS-BL delay), peak strain dispersion (PSD) and strain delay index. Right ventricle function was assessed using tricuspid annular plane systolic excursion (TAPSE) and tissue Doppler velocity of the lateral tricuspid annulus (S'). A total of 69 patients (age: 75.6 ± 10.5 years; males: 75%) were enrolled. There were no differences in LV ejection fraction and GLS between s-HBP and ns-HBP modes: 59% versus 60%, and -15.6% versus -15.7%, respectively; as well as no difference in BS-BL delay and strain delay index. The PSD value was higher in the ns-HBP group than in the s-HBP group with the most pronounced difference in the basal LV segments. No differences in right ventricular function parameters (TAPSE and S') were found. CONCLUSION: The ns-HBP and s-HBP modes seem comparable regarding ventricular function. The dyssynchrony parameters were significantly higher during ns-HBP, however, the difference seems modest and clarification of its impact on LV function requires a larger long-term study.