Two operational modes for Lab-In-Syringe automation of direct-immersion single-drop microextraction have been developed and critically compared using lead in drinking water as the model analyte. Dithizone was used in the presence of masking additives as a sensitive chromogenic complexing reagent. The analytical procedure was carried out inside the void of an automatic syringe pump. Normal pump orientation was used to study extraction in a floating drop of a toluene-hexanol mixture. Placing the syringe upside-down allowed the use of a denser-than-water drop of chloroform for the extraction. A magnetic stirring bar was placed inside the syringe for homogenous mixing of the aqueous phase and enabled in-drop stirring in the second configuration while resulting in enhanced extraction efficiency. The use of a syringe as the extraction chamber allowed drop confinement and support by gravitational differences in the syringe inlet. Keeping the stirring rates low, problems related to solvent dispersion such as droplet collection were avoided. With a drop volume of 60 µL, limits of detection of 75 nmol L-1 and 23 nmol L-1 were achieved for the floating drop extraction and the in-drop stirring approaches, respectively. Both methods were characterized by repeatability with RSD typically below 5%, quantitative analyte recoveries, and analyte selectivity achieved by interference masking. Operational differences were critically compared. The proposed methods permitted the routine determination of lead in drinking water to be achieved in less than 6 min.
We have developed a new microextraction technique for equilibrium, non-exhaustive analyte preconcentration from aqueous solutions into organic solvents lighter than water. The key point of the method is application of specially designed and optimized bell-shaped extraction device, BSED. The technique has been tested and applied to the preconcentration of selected volatile and semi volatile compounds which were determined by gas chromatography/mass spectrometry in spiked water samples. The significant parameters of the extraction have been found using chemometric procedures and these parameters were optimized using the central composite design (CCD) for two solvents. The analyte preconcentration factors were in a range from 8.3 to 161.8 (repeatability from 7 to 14%) for heptane, and 50.0-105.0 (repeatability from 0 to 5%) for tert-butyl acetate. The reproducibility of the technique was within 1-8%. The values of limits of detection and determination were 0.1-3.3 ng mL(-1) for heptane and 0.3-10.7 ng mL(-1) for tert-butyl acetate. The new microextraction technique has been found to be a cheap, simple and flexible alternative to the common procedures, such as SPME or LLME. This BSED-LLME technique can also be combined with other separation methods, e.g., HPLC or CE.
- MeSH
- chemické látky znečišťující vodu analýza izolace a purifikace MeSH
- design vybavení MeSH
- mikroextrakce kapalné fáze přístrojové vybavení metody MeSH
- minerální vody analýza MeSH
- pitná voda analýza MeSH
- plynová chromatografie s hmotnostně spektrometrickou detekcí metody MeSH
- reprodukovatelnost výsledků MeSH
- voda analýza MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH