In this study, we show the repetitive detection of toluene on a tapered optical fiber element (OFE) with an attached layer of Pseudomonas putida TVA8 bioluminescent bioreporters. The bioluminescent cell layer was attached on polished quartz modified with (3-aminopropyl)triethoxysilane (APTES). The repeatability of the preparation of the optical probe and its use was demonstrated with five differently shaped OFEs. The intensity of measured bioluminescence was minimally influenced by the OFE shape, possessing transmittances between 1.41% and 5.00%. OFE probes layered with P. putida TVA8 were used to monitor liquid toluene over a two-week period. It was demonstrated that OFE probes layered with positively induced P. putida TVA8 bioreporters were reliable detectors of toluene. A toluene concentration of 26.5 mg/L was detected after <30 min after immersion of the probe in the toluene solution. Additional experiments also immobilized constitutively bioluminescent cells of E. coli 652T7, on OFEs with polyethyleneimine (PEI). These OFEs were repetitively induced with Lauria-Bertani (LB) nutrient medium. Bioluminescence appeared 15 minutes after immersion of the OFE in LB. A change in pH from 7 to 6 resulted in a decrease in bioluminescence that was not restored following additional nutrient inductions at pH 7. The E. coli 652T7 OFE probe was therefore sensitive to negative influences but could not be repetitively used.
Noncovalent molecular interactions between helquats, a new class of dicationic helical extended diquats, and several chiral acidic aromatic drugs and catalysts have been investigated using partial-filling affinity capillary electrophoresis (PF-ACE). Helquats dissolved at 1mM concentration in the aqueous background electrolyte (40mM Tris, 20mM acetic acid, pH 8.1) were introduced as ligand zones of variable length (0-130mm) into the hydroxypropylcellulose coated fused silica capillary whereas 0.1mM solutions of negatively charged chiral drugs or catalysts (warfarin, ibuprofen, mandelic acid, etodolac, binaphthyl phosphate and 11 other acidic aromatic compounds) were applied as a short analyte zone at the injection capillary end. After application of electric field, analyte and ligand migrated against each other and in case of their interactions, migration time of the analyte was increasing with increasing length of the ligand zone. From the tested compounds, only isomers of those exhibiting helical chirality and/or possessing conjugated aromatic systems were enantioselectively separated through their differential interactions with helquats. Some compounds with conjugated aromatic groups interacted with helquats moderately strongly but non-enantiospecifically. Small compounds with single benzene ring exhibited no or very weak non-enantiospecific interactions. PF-ACE method allowed to determine binding constants of the analyte-helquat complexes from the changes of migration times of the analytes. Binding constants of the weakest complexes of the analytes with helquats were less than 50L/mol, whereas binding constants of the strongest complexes were in the range 1 000-1 400L/mol.
Collection of exhaled breath condensate (EBC) is a relatively simple noninvasive method of breath analysis; however, no data have been reported that would relate concentration of volatile compounds in EBC to their gaseous concentrations in exhaled air. The aim of the study was to investigate which volatile compounds are present in EBC and how their concentrations relate to results of direct breath analysis. Thus, samples of EBC were collected in a standard way from several subjects and absolute levels of several common volatile breath metabolites (ammonia, acetone, ethanol, methanol, propanol, isoprene, hydrogen cyanide, formaldehyde and acetaldehyde) were then determined in their headspace using selected ion flow tube mass spectrometry (SIFT-MS). Results are compared with those from on-line breath analyses carried out immediately before collecting the EBC samples. It has been demonstrated that SIFT-MS can be used to quantify the concentrations of volatiles in EBC samples and that, for methanol, ammonia, ethanol and acetone, the EBC concentrations correlate with the direct breath levels. However, the EBC concentrations of isoprene, formaldehyde, acetaldehyde, hydrogen cyanide and propanol do not correlate with direct breath measurements. Copyright (c) 2008 John Wiley & Sons, Ltd.
- MeSH
- analýza selhání vybavení MeSH
- aromatické uhlovodíky analýza MeSH
- dechové testy metody přístrojové vybavení MeSH
- design vybavení MeSH
- hmotnostní spektrometrie s elektrosprejovou ionizací metody přístrojové vybavení MeSH
- lidé MeSH
- odběr biologického vzorku metody přístrojové vybavení MeSH
- průtoková injekční analýza metody přístrojové vybavení MeSH
- reprodukovatelnost výsledků MeSH
- senzitivita a specificita MeSH
- volatilizace MeSH
- Check Tag
- lidé MeSH
The influence of polycyclic aromatic hydrocarbons (PAH) in soil on plant production quality was investigated. A series of pot, field, and laboratory tests were performed. The results showed that the transfer of PAHs into plants is influenced mainly by chemical characteristics of aromatics, by soil characteristics (the content and quality of organic matter) and by plant characteristics (plant species and bodies). The pot and field tests confirmed the prevailing influence of emissions on the PAH load of mustard shoots compared with PAH transfer from the soil. Nevertheless, an increased transfer of PAHs containing less aromatic rings into the middle parts of carrot roots was confirmed for sandy soils. Increased contents of PAHs were also detected in primary bark of carrot roots in sludge application. These findings were confirmed by laboratory extraction tests.