OBJECTIVE: The aim of our study was to establish whether or not tinnitus patients have higher platelet activity, as measured by plasma 11-dehydro-thromboxane B2 levels, compared with individuals without tinnitus. METHODS: The study group included patients without documented organic causes of tinnitus or a cause of non-vascular hearing impairment. Laboratory tests included complete blood count, biochemistry, coagulation activity, and thromboxane levels. To exclude a pathology in the cerebellopontine angle, CT and MRI were performed together with an X-ray scan of cervical vertebrae. For the purpose of this study, blood samples were screened for 11-dehydro-thromboxane B2 levels using commercial kits. RESULTS: A comparison of the main marker of increased platelet activity i.e., thromboxane levels of tinnitus patients with those of a control group, showed increased thromboxane levels in the former. The average plasma concentrations of 11-dehydro-thromboxane B2 were 2.0234±1.80 ng/ml in the group of tinnitus patients and 1.3247±1.33 ng/ml in the control group. Our results showed that patients with tinnitus have significantly higher values of 11-dehydro-thromboxane B2. CONCLUSION: Tinnitus patients showed higher levels of increased platelet activity, a marker that may play an important role in the pathogenesis of tinnitus.
- MeSH
- dospělí MeSH
- hemokoagulace MeSH
- lidé středního věku MeSH
- lidé MeSH
- longitudinální studie MeSH
- thromboxan B2 analogy a deriváty krev MeSH
- tinnitus krev MeSH
- trombocyty metabolismus MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: Platelet function testing is often affected by the existence of different pre-analytical variables that can cause platelet activation. The aim of this study was to assess the effect of such variables that are present when samples are taken (different anticoagulants, incubation temperature, and storage conditions) to select those which enable to reach optimal range of measured plasma concentrations of the two stable thromboxane A₂ metabolites, that is, thromboxane B₂ (TxB₂) and 11-dehydrothromboxane B₂ (11-dTxB₂). MATERIALS AND METHODS: For the purpose of this study, whole blood samples obtained from 20 volunteers were screened for TxB₂ and 11-dTxB₂ concentrations using commercial EIA kits (Cayman Chemicals™; Neogen™) in relation to the effect of different anticoagulants, using different incubation temperatures and storage conditions. RESULTS: Trisodium citrate has been shown not to be affecting the TxB₂ and 11-dTxB₂ concentrations compared with the values measured in the serum. Incubation of the samples for 1 h at 37 °C and freezing at -20 °C or -80 °C give the most suitable concentration range of both thromboxanes in the used EIA measurement. CONCLUSION: This study describes the setup of such pre-analytical phase conditions that enable the screening of platelet function in terms of the plasma concentrations of TxB₂ and 11-dTxB₂ in selected EIA measurement.
- MeSH
- antikoagulancia farmakologie MeSH
- Aspirin terapeutické užití MeSH
- časové faktory MeSH
- citráty farmakologie MeSH
- imunoenzymatické techniky MeSH
- inhibitory agregace trombocytů farmakologie MeSH
- inhibitory cyklooxygenasy farmakologie MeSH
- lidé MeSH
- odběr biologického vzorku * MeSH
- teplota MeSH
- thromboxan A2 krev metabolismus MeSH
- thromboxan B2 analogy a deriváty krev metabolismus MeSH
- trombocyty účinky léků metabolismus MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- srovnávací studie MeSH
BACKGROUND: Thromboxane B2 (TxB2) and particularly 11-dehydrothromboxane B2 (11-dTxB2) are widely used as prognostic risk markers of platelet activation in cardiovascular diseases. The main errors in TxB2 and 11-dTxB2 determination include either low concentrations of circulating TxB2 (1 - 2 pg/mL) and 11-dTxB2 (0.9 - 4.3 pg/mL) or rather high transiency (mean TxB2 half-life is approximately 5 minutes) as well as an incorrect pre-analytical phase set up. The aim of this study was to investigate the impact of a widely used purification step on the results of enzyme immunosorbent assay (EIA)--based measurement of the two selected thromboxanes. METHODS: For the purpose of this study, 20 plasma samples (10 healthy donors, 10 patients under treatment with acetylsalicylic acid) were screened for TxB2 and 11-dTxB2 concentrations using commercial competitive EIA kits (Cayman Chemicals, Tallinn, Estonia; Neogen, Lexington, KY, USA) with or without the introduction of the purification procedure. RESULTS: The purification step does not significantly affect the results of EIA measurements of the two of TxA2 metabolites (TxB2, 11-dTxB2) in human plasma. The levels of TxB2 and 11-dTxB2 determined in the plasma samples were not significantly changed (p < 0.05) when the purification step was omitted compared to the purified samples. CONCLUSIONS: This study establishes a protocol allowing for reliable and reproducible plasma TxB2 and 11-dTxB2 EIA measurement for routine basic screening of platelet function.
- MeSH
- aktivace trombocytů účinky léků MeSH
- antiflogistika nesteroidní farmakologie MeSH
- Aspirin farmakologie MeSH
- extrakce na pevné fázi metody MeSH
- imunoenzymatické techniky metody MeSH
- kardiovaskulární nemoci krev diagnóza MeSH
- lidé MeSH
- prognóza MeSH
- reagenční diagnostické soupravy MeSH
- reprodukovatelnost výsledků MeSH
- thromboxan B2 analogy a deriváty krev MeSH
- trombocyty účinky léků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
AIM: Elevated urinary 11-dehydrothromboxane levels place patients at an increased risk for experiencing cardiovascular events. Statins exert an inhibitory effect on platelets. The aim of our study was to determine the effect of 3-month statin therapy on 11-dehydrothromboxane elimination in two groups of patients, one not receiving antiplatelet therapy with acetylsalicylic acid and the other receiving 100 mg acetylsalicylic acid per day. METHODS: We examined the urinary levels of 11-dehydrothromboxane in a total of 58 patients before and after 3-month therapy with a statin at standard doses (simvastatin, fluvastatin, atorvastatin). We also examined the plasma levels of total cholesterol, triglycerides, LDL- and HDL-cholesterol, C-reactive protein, and blood glucose. RESULTS: After 3-month statin therapy, both groups of patients (with and without antiplatelet therapy) showed a significant decrease in urinary 11-dehydrothromboxane levels. Significant decreases were also seen in LDL- and total cholesterol, and C-reactive protein. Changes in the other parameters were not significant. CONCLUSION: Three-month statin therapy significant reduces the rate of 11-dehydrothromboxane elimination, even in patients on acetylsalicylic acid. In addition to its usual lipid-lowering effect, it significantly decreases the plasma levels of C-reactive protein. Combination therapy with a statin plus acetylsalicylic acid may be effective even in patients with incomplete thromboxane inhibition on antiplatelet therapy with acetylsalicylic acid.
- MeSH
- Aspirin terapeutické užití MeSH
- biologické markery krev moč MeSH
- C-reaktivní protein metabolismus MeSH
- časové faktory MeSH
- down regulace MeSH
- HDL-cholesterol krev MeSH
- indoly terapeutické užití MeSH
- inhibitory agregace trombocytů terapeutické užití MeSH
- krevní glukóza metabolismus MeSH
- kyseliny heptylové terapeutické užití MeSH
- kyseliny mastné mononenasycené terapeutické užití MeSH
- LDL-cholesterol krev MeSH
- lidé středního věku MeSH
- lidé MeSH
- pyrroly terapeutické užití MeSH
- senioři MeSH
- simvastatin terapeutické užití MeSH
- statiny terapeutické užití MeSH
- thromboxan B2 analogy a deriváty moč MeSH
- triglyceridy krev MeSH
- trombocyty účinky léků metabolismus MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
- Geografické názvy
- Česká republika MeSH