G-M detector Dotaz Zobrazit nápovědu
There are various different detectors, which can be used for radiotherapy measurements, and more are about to be adopted. Hybrid pixel detectors (HPD) have been originally developed for the high energy physics. However, over the last few years they also expanded in the medical physics. Novel 2D detector Pantherpix is a HPD designed specifically for the radiotherapy. In this article, its properties are characterised and an assessment of its use in radiotherapy photon beams is provided. Properties such as response stability, response linearity, angular dependence and energy dependence were studied. In order to prove sufficient clinical quality for relative dosimetry, further measurements were undertaken (i.e. dose profiles and collimator scatter factors). Acquired results were compared with ion chamber and gafchromic film results. Namely the applicability of PhPix for cobalt beam therapy, which is still widely used (and will be used in near future) in economically less developed countries, is considered.
- MeSH
- celková dávka radioterapie MeSH
- radiometrie * MeSH
- Publikační typ
- časopisecké články MeSH
A neutral marker of the EOF can gain a nonzero effective mobility because of its possible interaction with a charged complexing agent, such as a chiral selector in CE. We determined effective mobilities of four compounds often used as EOF markers (dimethyl sulfoxide, mesityl oxide, nitromethane, and thiourea) in the BGE-containing sulfated β-CD (60 g/L). All the compounds studied were measurably mobilized by their interaction with the selector. The highest effective mobility (-3.0·10(-9) m(2) s(-1) V(-1)) was observed for thiourea and the lowest (-1.5·10(-9) m(2) s(-1) V(-1)) for dimethyl sulfoxide and nitromethane. The mobilities were determined by a new two-detector pressure mobilization method (2d method), which we propose, and the results were confirmed by standard CE measurements. In the 2d method, one marker zone is situated in the BGE containing the charged selector, while the second marker zone is surrounded with a selector-free BGE, which prevents its complexation. The initial distance between the two marker zones equals the capillary length from the inlet to the first detector. After a brief voltage application, the final distance between the marker zones is determined based on known capillary length from the first to the second detector. The difference between these two distances determines the effective mobility.
- MeSH
- aceton chemie MeSH
- beta-cyklodextriny chemie MeSH
- chemické modely * MeSH
- dimethylsulfoxid chemie MeSH
- elektroforéza kapilární metody MeSH
- elektrolyty chemie MeSH
- elektroosmóza metody MeSH
- hexanony chemie MeSH
- methan analogy a deriváty chemie MeSH
- nitroparafiny chemie MeSH
- thiomočovina chemie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Vertebral labelling and segmentation are two fundamental tasks in an automated spine processing pipeline. Reliable and accurate processing of spine images is expected to benefit clinical decision support systems for diagnosis, surgery planning, and population-based analysis of spine and bone health. However, designing automated algorithms for spine processing is challenging predominantly due to considerable variations in anatomy and acquisition protocols and due to a severe shortage of publicly available data. Addressing these limitations, the Large Scale Vertebrae Segmentation Challenge (VerSe) was organised in conjunction with the International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI) in 2019 and 2020, with a call for algorithms tackling the labelling and segmentation of vertebrae. Two datasets containing a total of 374 multi-detector CT scans from 355 patients were prepared and 4505 vertebrae have individually been annotated at voxel level by a human-machine hybrid algorithm (https://osf.io/nqjyw/, https://osf.io/t98fz/). A total of 25 algorithms were benchmarked on these datasets. In this work, we present the results of this evaluation and further investigate the performance variation at the vertebra level, scan level, and different fields of view. We also evaluate the generalisability of the approaches to an implicit domain shift in data by evaluating the top-performing algorithms of one challenge iteration on data from the other iteration. The principal takeaway from VerSe: the performance of an algorithm in labelling and segmenting a spine scan hinges on its ability to correctly identify vertebrae in cases of rare anatomical variations. The VerSe content and code can be accessed at: https://github.com/anjany/verse.
PURPOSE: The time structures of proton spot delivery in proton pencil beam scanning (PBS) radiation therapy are essential in many clinical applications. This study aims to characterize the time structures of proton PBS delivered by both synchrotron and synchrocyclotron accelerators using a non-invasive technique based on scattered particle tracking. METHODS: A pixelated semiconductor detector, AdvaPIX-Timepix3, with a temporal resolution of 1.56 ns, was employed to measure time of arrival of secondary particles generated by a proton beam. The detector was placed laterally to the high-flux area of the beam in order to allow for single particle detection and not interfere with the treatment. The detector recorded counts of radiation events, their deposited energy and the timestamp associated with the single events. Individual recorded events and their temporal characteristics were used to analyze beam time structures, including energy layer switch time, magnet switch time, spot switch time, and the scanning speeds in the x and y directions. All the measurements were repeated 30 times on three dates, reducing statistical uncertainty. RESULTS: The uncertainty of the measured energy layer switch times, magnet switch time, and the spot switch time were all within 1% of average values. The scanning speeds uncertainties were within 1.5% and are more precise than previously reported results. The measurements also revealed continuous sub-milliseconds proton spills at a low dose rate for the synchrotron accelerator and radiofrequency pulses at 7 μs and 1 ms repetition time for the synchrocyclotron accelerator. CONCLUSION: The AdvaPIX-Timepix3 detector can be used to directly measure and monitor time structures on microseconds scale of the PBS proton beam delivery. This method yielded results with high precision and is completely independent of the machine log files.
- MeSH
- časové faktory MeSH
- částice - urychlovače * přístrojové vybavení MeSH
- celková dávka radioterapie * MeSH
- lidé MeSH
- nádory radioterapie MeSH
- plánování radioterapie pomocí počítače * metody MeSH
- polovodiče * MeSH
- protonová terapie * přístrojové vybavení MeSH
- protony MeSH
- synchrotrony přístrojové vybavení MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- MeSH
- glukosa metabolismus MeSH
- mozek metabolismus MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
RNA variants that emerge from editing and alternative splicing form important regulatory stages in protein signalling. In this report, we apply an integrated DNA and RNA variant detection workbench to define the range of RNA variants that deviate from the reference genome in a human melanoma cell model. The RNA variants can be grouped into (i) classic ADAR-like or APOBEC-like RNA editing events and (ii) multiple-nucleotide variants (MNVs) including three and six base pair in-frame non-canonical unmapped exons. We focus on validating representative genes of these classes. First, clustered non-synonymous RNA edits (A-I) in the CDK13 gene were validated by Sanger sequencing to confirm the integrity of the RNA variant detection workbench. Second, a highly conserved RNA variant in the MAP4K5 gene was detected that results most likely from the splicing of a non-canonical three-base exon. The two RNA variants produced from the MAP4K5 locus deviate from the genomic reference sequence and produce V569E or V569del isoform variants. Low doses of splicing inhibitors demonstrated that the MAP4K5-V569E variant emerges from an SF3B1-dependent splicing event. Mass spectrometry of the recombinant SBP-tagged MAP4K5V569E and MAP4K5V569del proteins pull-downs in transfected cell systems was used to identify the protein-protein interactions of these two MAP4K5 isoforms and propose possible functions. Together these data highlight the utility of this integrated DNA and RNA variant detection platform to detect RNA variants in cancer cells and support future analysis of RNA variant detection in cancer tissue.
- MeSH
- alternativní sestřih * MeSH
- DNA genetika MeSH
- editace RNA MeSH
- exony * MeSH
- izoenzymy MeSH
- lidé MeSH
- protein-serin-threoninkinasy genetika MeSH
- RNA genetika MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Elements of the Eye 311 -- 12.2 Some Other Elements of the Eye 313 -- 12.3 The Retina—The Light Detector
2nd ed. xv, 394 s., il.
- MeSH
- biofyzika MeSH
- fyziologie MeSH
- Konspekt
- Biochemie. Molekulární biologie. Biofyzika
- NLK Obory
- fyzika, biofyzika