Single drop microextraction
Dotaz
Zobrazit nápovědu
Two operational modes for Lab-In-Syringe automation of direct-immersion single-drop microextraction have been developed and critically compared using lead in drinking water as the model analyte. Dithizone was used in the presence of masking additives as a sensitive chromogenic complexing reagent. The analytical procedure was carried out inside the void of an automatic syringe pump. Normal pump orientation was used to study extraction in a floating drop of a toluene-hexanol mixture. Placing the syringe upside-down allowed the use of a denser-than-water drop of chloroform for the extraction. A magnetic stirring bar was placed inside the syringe for homogenous mixing of the aqueous phase and enabled in-drop stirring in the second configuration while resulting in enhanced extraction efficiency. The use of a syringe as the extraction chamber allowed drop confinement and support by gravitational differences in the syringe inlet. Keeping the stirring rates low, problems related to solvent dispersion such as droplet collection were avoided. With a drop volume of 60 µL, limits of detection of 75 nmol L-1 and 23 nmol L-1 were achieved for the floating drop extraction and the in-drop stirring approaches, respectively. Both methods were characterized by repeatability with RSD typically below 5%, quantitative analyte recoveries, and analyte selectivity achieved by interference masking. Operational differences were critically compared. The proposed methods permitted the routine determination of lead in drinking water to be achieved in less than 6 min.
A method employing the headspace single-drop microextraction (HS-SDME) is presented for the determination of essential oils in dried herbal leaves. By optimising the key experimental parameters, a linear response for the individual target compounds was obtained in the concentration range from LOQ to 4 mg/mL (r(2) = 0.9912-0.9998), with LODs from 3.3 up to 20.5 microg per 100 g of dried leaves, and the repeatability within the RSD of 2.1-8.9%. The HS-SDME-based procedure, enabling a rapid and simple analysis of essential oils in herbs, was applied to selected real samples (nine essential oils in four different samples) in combination with GC-FID identification and quantification of the target volatiles.
- MeSH
- chromatografie plynová metody MeSH
- financování organizované MeSH
- oleje prchavé analýza MeSH
- teplota MeSH
- Publikační typ
- validační studie MeSH
The review presents an evaluation of the development of on-line, at-line and in-line sample treatment coupled with capillary and microchip electrophoresis over the last 10 years. In the first part, it describes different types of flow-gating interfaces (FGI) such as cross-FGI, coaxial-FGI, sheet-flow-FGI, and air-assisted-FGI and their fabrication using molding into polydimethylsiloxane and commercially available fittings. The second part deals with the coupling of capillary and microchip electrophoresis with microdialysis, solid-phase, liquid-phase, and membrane based extraction techniques. It mainly focuses on modern techniques such as extraction across supported liquid membrane, electroextraction, single drop microextraction, head space microextraction, and microdialysis with high spatial and temporal resolution. Finally, the design of sequential electrophoretic analysers and fabrication of SPE microcartridges with monolithic and molecularly imprinted polymeric sorbents are discussed. Applications include the monitoring of metabolites, neurotransmitters, peptides and proteins in body fluids and tissues to study processes in living organisms, as well as the monitoring of nutrients, minerals and waste compounds in food, natural and wastewater.
- MeSH
- elektroforéza kapilární metody MeSH
- elektroforéza mikročipová * metody MeSH
- mikrodialýza MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH