OBJECTIVES: To develop an Outcome Measures in Rheumatology (OMERACT) ultrasonography score for monitoring disease activity in giant cell arteritis (GCA) and evaluate its metric properties. METHODS: The OMERACT Instrument Selection Algorithm was followed. Forty-nine members of the OMERACT ultrasonography large vessel vasculitis working group were invited to seven Delphi rounds. An online reliability exercise was conducted using images of bilateral common temporal arteries, parietal and frontal branches as well as axillary arteries from 16 patients with GCA and 7 controls. Sensitivity to change and convergent construct validity were tested using data from a prospective cohort of patients with new GCA in which ultrasound-based intima-media thickness (IMT) measurements were conducted at weeks 1, 3, 6, 12 and 24. RESULTS: Agreement was obtained (92.7%) for the OMERACT GCA Ultrasonography Score (OGUS), calculated as follows: sum of IMT measured in every segment divided by the rounded cut-off values of IMTs in each segment. The resulting value is then divided by the number of segments available. Thirty-five members conducted the reliability exercise, the interrater intraclass correlation coefficient (ICC) for the OGUS was 0.72-0.84 and the median intrareader ICC was 0.91. The prospective cohort consisted of 52 patients. Sensitivity to change between baseline and each follow-up visit up to week 24 yielded standardised mean differences from -1.19 to -2.16, corresponding to large and very large magnitudes of change, respectively. OGUS correlated moderately with erythrocyte sedimentation rate, C reactive protein and Birmingham Vasculitis Activity Score (corrcoeff 0.37-0.48). CONCLUSION: We developed a provisional OGUS for potential use in clinical trials.
- MeSH
- arteriae temporales diagnostické zobrazování MeSH
- intimomediální šíře tepenné stěny MeSH
- lidé MeSH
- obrovskobuněčná arteritida * diagnostické zobrazování MeSH
- prospektivní studie MeSH
- reprodukovatelnost výsledků MeSH
- ultrasonografie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVE: To evaluate the intraobserver and interobserver reliability of the ultrasonographic (US) assessment of subtalar joint (STJ) synovitis in patients with rheumatoid arthritis (RA). METHODS: Following a Delphi process, 12 sonographers conducted an US reliability exercise on 10 RA patients with hindfoot pain. The anteromedial, posteromedial, and posterolateral STJ was assessed using B-mode and power Doppler (PD) techniques according to an agreed US protocol and using a 4-grade semiquantitative grading score for synovitis [synovial hypertrophy (SH) and signal] and a dichotomous score for the presence of joint effusion (JE). Intraobserver and interobserver reliability were computed by Cohen's and Light's κ. Weighted κ coefficients with absolute weighting were computed for B-mode and PD signal. RESULTS: Mean weighted Cohen's κ for SH, PD, and JE were 0.80 (95% CI 0.62-0.98), 0.61 (95% CI 0.48-0.73), and 0.52 (95% CI 0.36-0.67), respectively. Weighted Cohen's κ for SH, PD, and JE in the anteromedial, posteromedial, and posterolateral STJ were -0.04 to 0.79, 0.42-0.95, and 0.28-0.77; 0.31-1, -0.05 to 0.65, and -0.2 to 0.69; 0.66-1, 0.52-1, and 0.42-0.88, respectively. Weighted Light's κ for SH was 0.67 (95% CI 0.58-0.74), 0.46 (95% CI 0.35-0.59) for PD, and 0.16 (95% CI 0.08-0.27) for JE. Weighted Light's κ for SH, PD, and JE were 0.63 (95% CI 0.45-0.82), 0.33 (95% CI 0.19-0.42), and 0.09 (95% CI -0.01 to 0.19), for the anteromedial; 0.49 (95% CI 0.27-0.64), 0.35 (95% CI 0.27-0.4), and 0.04 (95% CI -0.06 to 0.1) for posteromedial; and 0.82 (95% CI 0.75-0.89), 0.66 (95% CI 0.56-0.8), and 0.18 (95% CI 0.04-0.34) for posterolateral STJ, respectively. CONCLUSION: Using a multisite assessment, US appears to be a reliable tool for assessing synovitis of STJ in RA.
- MeSH
- delfská metoda MeSH
- dospělí MeSH
- incidence MeSH
- konsensus MeSH
- lidé středního věku MeSH
- lidé MeSH
- reprodukovatelnost výsledků MeSH
- revmatoidní artritida patologie MeSH
- subtalární kloub diagnostické zobrazování patologie MeSH
- synovitida diagnostické zobrazování epidemiologie MeSH
- ultrasonografie dopplerovská metody normy MeSH
- výzkumný projekt MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
- systematický přehled MeSH
- MeSH
- duplexní dopplerovská ultrasonografie * MeSH
- falešně pozitivní reakce MeSH
- lidé MeSH
- synovitida ultrasonografie MeSH
- zápěstí ultrasonografie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
- úvodníky MeSH
OBJECTIVE: To develop the first ultrasound scoring system of tendon damage in rheumatoid arthritis (RA) and assess its intraobserver and interobserver reliability. METHODS: We conducted a Delphi study on ultrasound-defined tendon damage and ultrasound scoring system of tendon damage in RA among 35 international rheumatologists with experience in musculoskeletal ultrasound. Twelve patients with RA were included and assessed twice by 12 rheumatologists-sonographers. Ultrasound examination for tendon damage in B mode of five wrist extensor compartments (extensor carpi radialis brevis and longus; extensor pollicis longus; extensor digitorum communis; extensor digiti minimi; extensor carpi ulnaris) and one ankle tendon (tibialis posterior) was performed blindly, independently and bilaterally in each patient. Intraobserver and interobserver reliability were calculated by κ coefficients. RESULTS: A three-grade semiquantitative scoring system was agreed for scoring tendon damage in B mode. The mean intraobserver reliability for tendon damage scoring was excellent (κ value 0.91). The mean interobserver reliability assessment showed good κ values (κ value 0.75). The most reliable were the extensor digiti minimi, the extensor carpi ulnaris, and the tibialis posterior tendons. An ultrasound reference image atlas of tenosynovitis and tendon damage was also developed. CONCLUSIONS: Ultrasound is a reproducible tool for evaluating tendon damage in RA. This study strongly supports a new reliable ultrasound scoring system for tendon damage.
- MeSH
- delfská metoda MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- odchylka pozorovatele MeSH
- poranění šlachy etiologie ultrasonografie MeSH
- reprodukovatelnost výsledků MeSH
- revmatoidní artritida komplikace ultrasonografie MeSH
- ruptura etiologie ultrasonografie MeSH
- senioři MeSH
- šlachy ultrasonografie MeSH
- stupeň závažnosti nemoci MeSH
- tenosynovitida etiologie ultrasonografie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- konsensus - konference MeSH
- práce podpořená grantem MeSH