17051397 OR Atlantoaxial fixation using the polyaxial screw-rod system
Dotaz
Zobrazit nápovědu
The aim of this study is to evaluate the first results of the atlantoaxial fixation using polyaxial screw-rod system. Twenty-eight patients followed-up 12-29 months (average 17.1 months) were included in this study. The average age was 59.5 years (range 23-89 years). The atlantoaxial fusion was employed in 20 patients for an acute injury to the upper cervical spine, in 1 patient with rheumatoid arthritis for atlantoaxial vertical instability, in 1 patient for C1-C2 osteoarthritis, in 2 patients for malunion of the fractured dens. Temporary fixation was applied in two patients for type III displaced fractures of the dens and in two patients for the atlantoaxial rotatory dislocation. Retrospectively, we evaluated operative time, intraoperative bleeding and the interval of X-ray exposure. The resulting condition was subjectively evaluated by patients. We evaluated also the placement, direction and length of the screws. Fusion or stability in the temporary fixation was evaluated on radiographs taken at 3, 6, 12 weeks and 6 and 12 months after the surgery. As concerns complications, intraoperatively we monitored injury of the nerve structures and the vertebral artery. Monitoring of postoperative complications was focused on delayed healing of the wound, breaking or loosening of screws and development of malunion. Operative time ranged from 35 to 155 min, (average 83 min). Intraoperative blood loss ranged from 50 to 1,500 ml (average 540 ml). The image intensifier was used for a period of 24 s to 2 min 36 s (average 1 min 6 s). Within the postoperative evaluation, four patients complained of paresthesia in the region innervated by the greater occipital nerve. A total of 56 screws were inserted into C1, their length ranged from 26 to 34 mm (average, 30.8 mm). All screws were positioned correctly in the C1 lateral mass. Another 56 screws were inserted into C2. Their length ranged from 28 to 36 mm (average 31.4 mm). Three screws were malpositioned: one screw perforated the spinal canal and two screws protruded into the vertebral artery canal. C1-C2 stability was achieved in all patients 12 weeks after the surgery. No clinically manifested injury of the vertebral artery or nerve structures was observed in any of these cases. As for postoperative complications, we recorded wound dehiscence in one patient. The Harms C1-C2 fixation is a very effective method of stabilizing the atlantoaxial complex. The possibility of a temporary fixation without damage to the atlantoaxial joints and of reduction after the screws and rods had been inserted is quite unique.
- MeSH
- atlantoaxiální kloub chirurgie MeSH
- dens axis chirurgie zranění MeSH
- dospělí MeSH
- fraktury páteře chirurgie MeSH
- fúze páteře metody přístrojové vybavení MeSH
- kostní hřeby MeSH
- kostní šrouby MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- nestabilita kloubu chirurgie MeSH
- osteoartróza chirurgie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- klinické zkoušky MeSH
PURPOSE OF THE STUDY Atlantoaxial osteoarthritis (AAOA) is a clinical syndrome with signs distinctly different from those of degenerative sub-axial spine disease. Its diagnosis may long be delayed, partly because of insufficient knowledge and partly due to difficulties in interpreting both anteroposterior and lateral radiographs. The aim of this prospective study was to evaluate the first 27 AAOA patients treated at our department. MATERIAL From 2001 we performed atlantoaxial fixation with fusion in a total of 29 patients with painful arthritis of the atlantoaxial complex. The 27 patients treated before the end of 2010 were enrolled in the study and analysed in detail. This group included 13 women and 14 men aged between 35 and 72 years, with an average age of 53.5 years. In all patients atlantoaxial fixation was performed using the polyaxial screw-rod system according to Harms. METHODS The patients were followed up at 6 and 12 weeks, 6 and 12 months and then once a year after surgery. X-ray examinations were done at the same intervals as clinical examinations; functional radiographs were made at 12 to 14 weeks after surgery. The definitive analysis of the group was made in the range of 4 to 59 months (average, 25.7 months) after the primary operation. Patients' subjective evaluation was based on NPDI and VAS scores and a question of whether the patient would undergo the surgery again. Objective evaluation included clinical outcomes - pain and neurological findings; radiographic results - stability and healing of C1-C2 fusion; and complications during surgery and in early and late postoperative periods. As intra-operative complications were regarded those associated with the surgical approach, nerve injury and vertebral artery injury. Early post-operative complications included poor wound healing and changes in the patient's neurological status, late complications included instrumentation failure and infection. Patients' clinical status (NPDI, VAS) was statistically evaluated using the one-way ANOVA. RESULTS The mean VAS score was pre-operatively 7.0 and post-operatively 5.6 at 3 months, 5.0 at 6 months, 5.1 at 1 year; 3.9 at 2 years and 4.0 at 3 years. The mean NPDI value was pre-operatively 39.6 and post-operatively 38.7 at 3 months, 36.0 at 6 months, 34.5 at 1 year, 34.3 at 2 years and 33.1 at 3 years. The question of willingness to undergo the same operation again was answered in the affirmative by 21 patients (77.8%), in the negative by five (18.5%) and one patient did not know (3.7%). Complete bone fusion, as assessed by radiography or CT scanning, was achieved in 26 out of 27 patients (96.3%). In one patient the result was ambiguous but, at 3 months as well as the next follow-ups, C1-C2 complex stability was found. DISCUSSION All patients in our group underwent a unified system of clinical, radiological, CT and MRI examination. In the decision-making process, emphasis was placed on a correlation of clinical findings with CT scanning results. All patients were operated on from the posterior approach using the Harms method, and radiological outcomes were similar to those of Grob et al. who used the Magerl s technique of C1-C2 fixation. The VAS and NPDI scores demonstrated significant improvement as early as 3 post-operative months, with still further improvement in the following period. The stable clinical status of the patients was achieved at 2 years after surgery. From the practical standpoint we were interested in an answer to the question of whether the patients would be willing to undergo the procedure again. Almost 80% of affirmative answers testified to the correct choice of treatment. The values found corresponded to those reported by Grob at al. CONCLUSIONS Patients with painful osteoarthritis refractory to conservative treatment will benefit from atlantoaxial fixation and fusion. For the patient, restricted cervical rotation is acceptable in return for pain relief. From the surgical point of view, the risk of complications associated with the operative technique did not exceed a tolerable rate.
- MeSH
- atlas (obratel) MeSH
- axis MeSH
- dospělí MeSH
- fúze páteře metody MeSH
- kostní šrouby MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- senioři MeSH
- spondylartritida chirurgie komplikace radiografie MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
... Lateral mass screws and plates 8 spine „35 -- 2.6.5. Lateral mass screws and rods 8 5.1. ... ... Transpedicular screws 8 spinal unit „37 -- 2.7. Anterior cervical spine fixation 8 5.1.1. ... ... Rod-screw fixation systems 86 -- 10. Injuries to the upper cervical spine 90 -- 10.1. ... ... Atlantoaxial fixation by transarticular screws according to Magerl 130 -- 10.4.5.2. ... ... Atlantoaxial fixation using the polyaxial screw -rod system according to Harms 136 -- 10.5. ...
1st ed. xii, 290 s. : il., tab. ; 29 cm
- Konspekt
- Ortopedie. Chirurgie. Oftalmologie
- NLK Obory
- ortopedie
- traumatologie
- NLK Publikační typ
- kolektivní monografie