BACKGROUND: Arrhythmia management is a complex process involving both pharmacological and non-pharmacological approaches. Radiofrequency ablation is the pillar of nonpharmacological arrhythmia treatment. Unipolar ablation is considered to be the gold standard in the treatment of the majority of arrhythmias; however, its efficacy is limited to specific cases. In particular, the creation of deep or transmural lesions to eliminate intramurally originating arrhythmias remains inadequate. Bipolar ablation is proposed as an alternative to overcome unipolar ablation boundaries. RESULTS: Despite promising results gained from in vitro and animal studies showing that bipolar ablation is superior in creating transmural lesions, the use of bipolar ablation in daily clinical practice is limited. Several studies have been published showing that bipolar ablation is effective in the treatment of clinical arrhythmias after failed unipolar ablation, however, there is inconsistency regarding the safety of bipolar ablation within the available research papers. According to research evidence, the most common indications for bipolar ablation use are ventricular originating rhythmic disorders in patients with structural heart disease resistant to standard radiofrequency ablation. CONCLUSION: To allow wider clinical application the efficiency and safety of bipolar ablation need to be verified in future studies.
- MeSH
- katetrizační ablace metody MeSH
- lidé MeSH
- nemoci srdce komplikace terapie MeSH
- srdeční arytmie patologie terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
BACKGROUND: Long-term efficacy of catheter-based treatment of persistent atrial fibrillation is unsatisfactory. Minimally invasive surgical ablation techniques have been developed recently, but their efficacy has never been systematically tested. METHODS AND RESULTS: Seventy patients (median age, 63.5 years) with persistent atrial fibrillation underwent epicardial thoracoscopic radiofrequency pulmonary vein isolation, linear ablation, Marshal ligament disruption, and exclusion of the left atrial appendage. The procedure was followed by electroanatomic mapping and ablation (EAM) 2 to 3 months later. Only 76% of patients were in normal sinus rhythm at the beginning of EAM. All 4 pulmonary veins and the left atrium posterior wall were found isolated in 69% and 23% of patients, respectively. Arrhythmia-free survival off antiarrhythmic drugs 12 months after EAM was 77%. Using previously ineffective antiarrhythmic drugs and reablation procedures, arrhythmia free-survival increased to 97% during follow-up (mean, 936±432 days; range, 346-1509 days). The majority of arrhythmia recurrences occurred during the first 12 months after EAM. In a multivariable-adjusted estimates, left atrium volume >165 mL, absent normal sinus rhythm at admission for EAM, and inducibility of any sustained tachyarrhythmia at the end of EAM procedure were identified as independent correlates of atrial fibrillation recurrence. CONCLUSIONS: Our report demonstrated that the majority of patients after epicardial ablation, using bipolar radiofrequency instruments, required endocardial catheter ablation to complete the linear ablation lesions and a significant proportion of patients required spot-ablations to complete electric pulmonary vein isolation. Noninducibility of any arrhythmia after a staged hybrid procedure seemed to be the strongest correlate of long-term arrhythmia-free survival. CLINICAL TRIAL REGISTRATION: URL: www.ablace.cz. Unique identifier: cz-060520121617.
- MeSH
- elektrofyziologické techniky kardiologické MeSH
- endokard patofyziologie chirurgie MeSH
- fibrilace síní patofyziologie chirurgie MeSH
- katetrizační ablace metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- miniinvazivní chirurgické výkony MeSH
- rádiové vlny MeSH
- recidiva MeSH
- reoperace MeSH
- rizikové faktory MeSH
- torakoskopie MeSH
- venae pulmonales chirurgie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: We evaluated the feasibility and effectiveness of thoracoscopic and a staged surgical and transcatheter ablation technique to treat stand-alone atrial fibrillation (AF). METHODS: . Between 2009 and 2016, a cohort of 65 patients underwent bilateral totally thoracoscopic ablation of symptomatic paroxysmal AF (n=30; 46%), persistent AF (n=18; 28%) or long-standing persistent AF (n=17; 26%) followed by catheter ablation in case of AF recurrence. Surgical box lesion procedure included bilateral pulmonary vein and left atrial posterior wall ablation using irrigated bipolar radiofrequency with documentation of conduction block. RESULTS: There were no intra- or peri-operative ablation-related complications. There was no operative mortality, no myocardial infarction, and no stroke. Skin-to-skin procedure time was 120.5 ± 22.0 min and the postoperative average length of stay was 8.1 ± 3.0 days. At discharge, 60 patients (92%) were in sinus rhythm. Median follow-up time was 866 days (IQR, 612-1185 days). One-year success rate after surgical procedure was 78% (off antiarrhythmic drugs). Eleven patients (17%) underwent catheter re-ablation. Sixty (92%) patients were free of atrial fibrillation after hybrid ablation (on demand) at 1 year follow up after the last ablation. The success at 24-months was achieved in 96% (paroxysmal) and 78% (persistent) patients. At the last follow-up control, 69% patients discontinued oral anticoagulant therapy. CONCLUSIONS: . Combination of mini-invasive surgical and endocardial treatment (two-stage hybrid procedure) is a safe and effective method for the treatment of isolated (lone) AF. This procedure provided good midterm outcomes.
- MeSH
- antiarytmika terapeutické užití MeSH
- délka operace MeSH
- délka pobytu statistika a číselné údaje MeSH
- elektrokardiografie ambulantní MeSH
- fibrilace síní farmakoterapie chirurgie MeSH
- Kaplanův-Meierův odhad MeSH
- katetrizační ablace metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- péče o pacienty v kritickém stavu statistika a číselné údaje MeSH
- studie proveditelnosti MeSH
- torakoskopie metody MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
OBJECTIVES: Hybrid ablation of atrial fibrillation (AF) is a promising treatment strategy; however, data regarding its efficacy and safety are still limited. METHODS: Patients with non-paroxysmal AF were enrolled. First, a thoracoscopic, epicardial isolation of pulmonary veins and the left atrial posterior wall ('box lesion') was performed; a novel unipolar/bipolar radiofrequency device was used. Moreover, in 12 patients enrolled thereafter, the left atrial appendage was occluded. Electrophysiological evaluation and catheter ablation were performed 2-3 months later, with the goal of verifying or completing (if needed) the box lesion and ablation of the ganglionated plexi and the cavotricuspid isthmus. Outcomes were assessed using 1-week and 24-h Holter monitoring, repeated echocardiography and laboratory measurements. RESULTS: Thirty-eight patients (13 persistent and 25 long-standing persistent AF) were enrolled with a mean AF duration of 33 ± 32.9 months. The procedure was successfully completed in 35 patients; 3 patients underwent only the surgical part because of a postoperative left atrial appendage thrombus (2 patients) and perioperative stroke (1 patient). After 6 months, 30 (86%) patients were arrhythmia-free, whereas 80% were also off antiarrhythmics. After 1 year, 28 (82%) patients were arrhythmia-free, 79% were off anti-arrhythmics and 47% were off anticoagulation treatment. Four (10.5%) serious postoperative complications occurred, including 1 stroke, 1 right phrenic nerve palsy and 2 pneumothoraxes with a need for drainage. Significant improvements were observed in echocardiographic, functional and serological parameters. CONCLUSIONS: Hybrid ablation is an effective treatment strategy for patients with persistent or long-standing persistent AF. Over 80% of patients were arrhythmia-free 1 year after the procedure. Sinus rhythm restoration was accompanied by improvements in functional, echocardiographic and serological markers.
- MeSH
- antiarytmika terapeutické užití MeSH
- echokardiografie MeSH
- elektrokardiografie ambulantní MeSH
- fibrilace síní chirurgie MeSH
- katetrizační ablace * MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- obnova funkce MeSH
- senioři MeSH
- venae pulmonales chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH