A significant proportion of patients who suffer from atrial fibrillation (AF) and are in need of thromboembolic protection are not treated with oral anticoagulation or discontinue this treatment shortly after its initiation. This undertreatment has not improved sufficiently despite the availability of direct oral anticoagulants which are associated with less major bleeding than vitamin K antagonists. Multiple reasons account for this, including bleeding events or ischaemic strokes whilst on anticoagulation, a serious risk of bleeding events, poor treatment compliance despite best educational attempts, or aversion to drug therapy. An alternative interventional therapy, which is not associated with long-term bleeding and is as effective as vitamin K anticoagulation, was introduced over 20 years ago. Because of significant improvements in procedural safety over the years, left atrial appendage closure, predominantly achieved using a catheter-based, device implantation approach, is increasingly favoured for the prevention of thromboembolic events in patients who cannot achieve effective anticoagulation. This management strategy is well known to the interventional cardiologist/electrophysiologist but is not more widely appreciated within cardiology or internal medicine. This article introduces the devices and briefly explains the implantation technique. The indications and device follow-up are more comprehensively described. Almost all physicians who care for adult patients will have many with AF. This practical guide, written within guideline/guidance boundaries, is aimed at those non-implanting physicians who may need to refer patients for consideration of this new therapy, which is becoming increasingly popular.
- MeSH
- antikoagulancia škodlivé účinky MeSH
- cévní mozková příhoda * prevence a kontrola komplikace MeSH
- dospělí MeSH
- fibrilace síní * komplikace diagnóza chirurgie MeSH
- konsensus MeSH
- krvácení chemicky indukované prevence a kontrola MeSH
- lékaři * MeSH
- lidé MeSH
- síňové ouško * chirurgie MeSH
- tromboembolie * etiologie prevence a kontrola MeSH
- uzávěr ouška levé síně MeSH
- vitamin K MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Aims: We aimed to compare patients' quality of life (QoL) after two types of atrial fibrillation (AF) treatment: a hybrid ablation strategy and a surgical CryoMaze procedure alone. Methods and results: Patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement with concomitant CryoMaze procedure were randomly assigned to undergo either radiofrequency catheter ablation after three months (Hybrid Group) or no further treatment (Surgery Group). QoL was compared using the Atrial Fibrillation Effect on Quality of Life (AFEQT) questionnaire. The AFEQT score was converted to the scale of 0 to 100 per cent points, i.e., a score of 0 corresponds to complete disability (or responding "extremely" limited, difficult, or bothersome to all questions answered), and a score of 100 corresponds to no disability (or responding "not at all" limited, difficult, or bothersome to all questions answered). In 106 Hybrid Group patients and 109 Surgery Group patients, both baseline and 12-month AFEQT data were available for final analysis. Patients' QoL did not differ between the Hybrid and Surgery Groups at baseline. At 12 months post-procedure, QoL improved significantly in both groups (from 61.9 ± 16.3 to 86.5 ± 13.4 and from 58.6 ± 14.9 to 81.5 ± 16.7 in the Hybrid Group and Surgery Group, respectively, P < 0.001). The 12-month AFEQT score was significantly higher in the Hybrid Group compared to the Surgery Group (P = 0.017). In an analysis based on AF recurrence, the QoL at 12 months was significantly higher in patients without AF recurrences compared to patients with AF recurrences (86.2 ± 14.0 vs 80.2 ± 16.8, P = 0.005). Conclusion: Compared to the CryoMaze procedure alone, the hybrid ablation strategy was associated with higher QoL 12 months post-procedure in patients with non-paroxysmal AF undergoing cardiac surgery for structural heart disease. Arrhythmia recurrence was the most significant denominator of the QoL after concomitant AF surgery.
- Klíčová slova
- CryoMaze,
- MeSH
- fibrilace síní * chirurgie MeSH
- kardiochirurgické výkony metody MeSH
- katetrizační ablace metody škodlivé účinky MeSH
- koronární bypass metody MeSH
- kvalita života MeSH
- lidé středního věku MeSH
- lidé MeSH
- maze procedura * metody MeSH
- průzkumy a dotazníky MeSH
- senioři MeSH
- statistika jako téma MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- práce podpořená grantem MeSH
- srovnávací studie MeSH
AIMS: Data on the hybrid atrial fibrillation (AF) treatment are lacking in patients with structural heart disease undergoing concomitant CryoMaze procedures. The aim was to assess whether the timely pre-emptive catheter ablation would achieve higher freedom from AF or atrial tachycardia (AT) and be associated with better clinical outcomes than surgical ablation alone. METHODS AND RESULTS: The trial investigated patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement with mandatory concomitant CryoMaze procedure who were randomly assigned to undergo either radiofrequency catheter ablation [Hybrid Group (HG)] or no further treatment (Surgery Group). The primary efficacy endpoint was the first recurrence of AF/AT without class I or III antiarrhythmic drugs as assessed by implantable cardiac monitors. The primary clinical endpoint was a composite of hospitalization for arrhythmia recurrence, worsening of heart failure, cardioembolic event, or major bleeding. We analysed 113 and 116 patients in the Hybrid and Surgery Groups, respectively, with a median follow-up of 715 (IQR: 528-1072) days. The primary efficacy endpoint was significantly reduced in the HG [41.1% vs. 67.4%, hazard ratio (HR) = 0.38, 95% confidence interval (CI): 0.26-0.57, P < 0.001] as well as the primary clinical endpoint (19.9% vs. 40.1%, HR = 0.51, 95% CI: 0.29-0.86, P = 0.012). The trial groups did not differ in all-cause mortality (10.6% vs. 8.6%, HR = 1.17, 95%CI: 0.51-2.71, P = 0.71). The major complications of catheter ablation were infrequent (1.9%). CONCLUSION: Pre-emptively performed catheter ablation after the CryoMaze procedure was safe and associated with higher freedom from AF/AT and improved clinical outcomes.
- MeSH
- antiarytmika terapeutické užití MeSH
- fibrilace síní * diagnóza chirurgie farmakoterapie MeSH
- katetrizační ablace * škodlivé účinky metody MeSH
- krvácení MeSH
- lidé MeSH
- recidiva MeSH
- supraventrikulární tachykardie * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
BACKGROUND: The presented study investigates the application of bi-arterial 3D printed models to guide transseptal puncture (TSP) in left atrial appendage closure (LAAC). AIMS: The objectives are to (1) test the feasibility of 3D printing (3DP) for TSP guidance, (2) analyse the distribution of the optimal TSP locations, and (3) define a CT-derived 2D parameter suitable for predicting the optimal TSP locations. METHODS: Preprocedural planning included multiplanar CT reconstruction, 3D segmentation, and 3DP. TSP was preprocedurally simulated in vitro at six defined sites. Based on the position of the sheath, TSP sites were classified as optimal, suboptimal, or nonoptimal. The aim was to target the TSP in the recommended position during the procedure. Procedure progress was assessed post hoc by the operator. RESULTS: Of 68 screened patients, 60 patients in five centers (mean age of 74.68 ± 7.64 years, 71.66% males) were prospectively analyzed (3DP failed in one case, and seven patients did not finally undergo the procedure). In 55 patients (91.66%), TSP was performed in the optimal location as recommended by the 3DP. The optimal locations for TSP were postero-inferior in 45.3%, mid-inferior in 45.3%, and antero-inferior in 37.7%, with a mean number of optimal segments of 1.34 ± 0.51 per patient. When the optimal TSP location was achieved, the procedure was considered difficult in only two (3.6%) patients (but in both due to complicated LAA anatomy). Comparing anterior versus posterior TSP in 2D CCT, two parameters differed significantly: (1) the angle supplementary to the LAA ostium and the interatrial septum angle (160.83° ± 9.42° vs. 146.49° ± 8.67°; p = 0.001), and (2) the angle between the LAA ostium and the mitral annulus (95.02° ± 3.73° vs. 107.38° ± 6.76°; p < 0.001), both in the sagittal plane. CONCLUSIONS: In vitro TSP simulation accurately determined the optimal TSP locations for LAAC and facilitated the procedure. More than one-third of the optimal TSP sites were anterior.
- MeSH
- 3D tisk MeSH
- fibrilace síní * terapie chirurgie MeSH
- lidé MeSH
- počítačová rentgenová tomografie MeSH
- punkce metody MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- síňové ouško * diagnostické zobrazování chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: Observational studies have shown low bleeding rates in patients with atrial fibrillation (AF) treated by left atrial appendage closure (LAAC); however, data from randomized studies are lacking. This study compared bleeding events among patients with AF treated by LAAC and nonvitamin K anticoagulants (NOAC). METHODS: The Prague-17 trial was a prospective, multicenter, randomized trial that compared LAAC to NOAC in high-risk AF patients. The primary endpoint was a composite of a cardioembolic event, cardiovascular death, and major and clinically relevant nonmajor bleeding (CRNMB) defined according to the International Society on Thrombosis and Hemostasis (ISTH). RESULTS: The trial enrolled 402 patients (201 per arm), and the median follow-up was 3.5 (IQR 2.6-4.2) years. Bleeding occurred in 24 patients (29 events) and 32 patients (40 events) in the LAAC and NOAC groups, respectively. Six of the LAAC bleeding events were procedure/device-related. In the primary intention-to-treat analysis, LAAC was associated with similar rates of ISTH major or CRNMB (sHR 0.75, 95% CI 0.44-1.27, p = 0.28), but with a reduction in nonprocedural major or CRNMB (sHR 0.55, 95% CI 0.31-0.97, p = 0.039). This reduction for nonprocedural bleeding with LAAC was mainly driven by a reduced rate of CRNMB (sHR for major bleeding 0.69, 95% CI 0.34-1.39, p = .30; sHR for CRNMB 0.43, 95% CI 0.18-1.03, p = 0.059). History of bleeding was a predictor of bleeding during follow-up. Gastrointestinal bleeding was the most common bleeding site in both groups. CONCLUSION: During the 4-year follow-up, LAAC was associated with less nonprocedural bleeding. The reduction is mainly driven by a decrease in CRNMB.
- MeSH
- antikoagulancia škodlivé účinky MeSH
- cévní mozková příhoda * diagnóza etiologie prevence a kontrola MeSH
- fibrilace síní * komplikace diagnóza farmakoterapie MeSH
- krvácení chemicky indukované MeSH
- lidé MeSH
- prospektivní studie MeSH
- síňové ouško * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
PURPOSE: Post-operative atrial fibrillation (PoAF) occurs in ~ 30% of patients after cardiac surgery. The etiology of PoAF is complex, but a disbalance in autonomic systems plays an important role. The goal of this study was to assess whether pre-operative heart rate variability analysis can predict the risk of PoAF. METHODS: Patients without a history of AF with an indication for cardiac surgery were included. Two-hour ECG recordings one day before surgery was used for the HRV analysis. Univariate and multivariate logistic regression, including all HRV parameters, their combination, and clinical variables, were calculated to find the best predictive model for post-operative AF. RESULTS: One hundred and thirty-seven patients (33 women) were enrolled in the study. PoAF occurred in 48 patients (35%, AF group); the remaining 89 patients were in the NoAF group. AF patients were significantly older (69.1 ± 8.6 vs. 63.4 ± 10.5 yrs., p = 0.002), and had higher CHA2DS2-VASc score (3 ± 1.4 vs. 2.5 ± 1.3, p = 0.01). In the multivariate regression model, parameters independently associated with higher risk of AF were pNN50, TINN, absolute power VLF, LF and HF, total power, SD2, and the Porta index. A combination of clinical variables with HRV parameters in the ROC analysis achieved an AUC of 0.86, a sensitivity of 0.95, and a specificity of 0.57 and was more effective in PoAF prediction than a combination of clinical variables alone. CONCLUSION: A combination of several HRV parameters is helpful in predicting the risk of PoAF. Attenuation of heart rate variability increases the risk for PoAF.
- MeSH
- fibrilace síní * diagnóza epidemiologie etiologie MeSH
- kardiochirurgické výkony * škodlivé účinky MeSH
- lidé MeSH
- pooperační komplikace diagnóza etiologie MeSH
- rizikové faktory MeSH
- ROC křivka MeSH
- srdeční frekvence fyziologie MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: Atrial fibrillation is common in patients with structural heart disease who are undergoing cardiac surgery. Surgical CryoMaze has been shown to be an effective treatment in several trials, but success rates have varied considerably, between 47-95%. The sequential hybrid approach, combining surgical CryoMaze followed by radiofrequency catheter ablation, can achieve high freedom from atrial arrhythmias. However, in patients with concomitant surgical atrial fibrillation treatment, data comparing the hybrid approach to CryoMaze alone are lacking. METHODS: The SurHyb study was designed as a prospective, open-label, multicentre randomized trial. Patients with non-paroxysmal atrial fibrillation who were scheduled for coronary artery bypass grafting or valve repair/replacement were randomized to either surgical CryoMaze alone or surgical CryoMaze followed by radiofrequency catheter ablation 3 months post-surgery. The primary outcome measure was arrhythmia-free survival without class I or III antiarrhythmic drugs, which has been evaluated using implantable cardiac monitors. CONCLUSIONS: This is the first randomized study that compares concomitant surgical CryoMaze alone with the staged hybrid surgical CryoMaze followed by catheter ablation, in patients with non-paroxysmal atrial fibrillation using rigorous rhythm monitoring. The results may contribute to the optimization of the treatment in patients undergoing concomitant CryoMaze for atrial fibrillation.
- MeSH
- antiarytmika terapeutické užití MeSH
- fibrilace síní * chirurgie farmakoterapie MeSH
- kardiochirurgické výkony * metody MeSH
- katetrizační ablace * metody MeSH
- lidé MeSH
- multicentrické studie jako téma MeSH
- prospektivní studie MeSH
- randomizované kontrolované studie jako téma MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- protokol klinické studie MeSH
- Publikační typ
- abstrakt z konference MeSH
- Publikační typ
- abstrakt z konference MeSH