AIMS: A recently published trial has shown no differences in outcomes between patients with new-onset supraventricular arrhythmia (SVA) in septic shock treated with either propafenone or amiodarone. However, these outcome data have not been evaluated in relation to the presence or absence of a dilated left atrium (LA). METHODS AND RESULTS: Patients with SVA and a left ventricular ejection fraction ≥ 35% were randomized to receive intravenous propafenone (70 mg bolus followed by 400-840 mg/24 h) or amiodarone (300 mg bolus followed by 600-1800 mg/24 h). They were divided into groups based on whether their end-systolic left atrial volume (LAVI) was ≥40 mL/m2. The subgroup outcomes assessed were survival at ICU discharge, 1 month, 3 months, 6 months, and 12 months. Propafenone cardioverted earlier (P = 0.009) and with fewer recurrences (P = 0.001) in the patients without LA enlargement (n = 133). Patients with LAVI < 40 mL/m2 demonstrated a mortality benefit of propafenone over the follow-up of 1 year [Cox regression, hazard ratio (HR) 0.6 (95% CI 0.4; 0.9), P = 0.014]. Patients with dilated LA (n = 37) achieved rhythm control earlier in amiodarone (P = 0.05) with similar rates of recurrences (P = 0.5) compared to propafenone. The outcomes for patients with LAVI ≥ 40 mL/m2 were less favourable with propafenone compared to amiodarone at 1 month [HR 3.6 (95% CI 1.03; 12.5), P = 0.045]; however, it did not reach statistical significance at 1 year [HR 1.9 (95% CI 0.8; 4.4), P = 0.138]. CONCLUSION: Patients with non-dilated LA who achieved rhythm control with propafenone in the setting of septic shock had better short-term and long-term outcomes than those treated with amiodarone, which seemed to be more effective in patients with LAVI ≥ 40 mL/m2. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03029169, registered on 24 January 2017.
- MeSH
- amiodaron * terapeutické užití aplikace a dávkování MeSH
- antiarytmika * terapeutické užití aplikace a dávkování MeSH
- lidé středního věku MeSH
- lidé MeSH
- propafenon * terapeutické užití aplikace a dávkování MeSH
- senioři MeSH
- septický šok * farmakoterapie patofyziologie MeSH
- srdeční síně * patofyziologie diagnostické zobrazování účinky léků MeSH
- supraventrikulární tachykardie * farmakoterapie patofyziologie MeSH
- tepový objem fyziologie účinky léků MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
The use of extracorporeal membrane oxygenation (ECMO) has recently increased exponentially. ECMO has become the preferred mode of organ support in refractory respiratory or circulatory failure. The fragile balance of haemostasis physiology is massively altered by the patient's critical condition and specifically the aetiology of the underlying disease. Furthermore, an application of ECMO conveys another disturbance of haemostasis due to blood-circuit interaction and the presence of an oxygenator. The purpose of this review is to summarise current knowledge on the anticoagulation management in patients undergoing ECMO therapy. The unfractionated heparin modality with monitoring of activated partial thromboplastin tests is considered to be a gold standard for anticoagulation in this specific subgroup of intensive care patients. However, alternative modalities with other agents are comprehensively discussed. Furthermore, other ways of monitoring can represent the actual state of coagulation in a more complex fashion, such as thromboelastometric/graphic methods, and might become more frequent. In conclusion, the coagulation system of patients with ECMO is altered by multiple variables, and there is a significant lack of evidence in this area. Therefore, a highly individualised approach is the best solution today.
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
PURPOSE: Acute onset supraventricular arrhythmias can contribute to haemodynamic compromise in septic shock. Both amiodarone and propafenone are available interventions, but their clinical effects have not yet been directly compared. METHODS: In this two-centre, prospective controlled parallel group double blind trial we recruited 209 septic shock patients with new-onset arrhythmia and a left ventricular ejection fraction above 35%. The patients were randomised in a 1:1 ratio to receive either intravenous propafenone (70 mg bolus followed by 400-840 mg/24 h) or amiodarone (300 mg bolus followed by 600-1800 mg/24 h). The primary outcomes were the proportion of patients who had sinus rhythm 24 h after the start of the infusion, time to restoration of the first sinus rhythm and the proportion of patients with arrhythmia recurrence. RESULTS: Out of 209 randomized patients, 200 (96%) received the study drug. After 24 h, 77 (72.8%) and 71 (67.3%) were in sinus rhythm (p = 0.4), restored after a median of 3.7 h (95% CI 2.3-6.8) and 7.3 h (95% CI 5-11), p = 0.02, with propafenone and amiodarone, respectively. The arrhythmia recurred in 54 (52%) patients treated with propafenone and in 80 (76%) with amiodarone, p < 0.001. Patients with a dilated left atrium had better rhythm control with amiodarone (6.4 h (95% CI 3.5; 14.1) until cardioversion vs 18 h (95% CI 2.8; 24.7) in propafenone, p = 0.05). CONCLUSION: Propafenone does not provide better rhythm control at 24 h yet offers faster cardioversion with fewer arrhythmia recurrences than with amiodarone, especially in patients with a non-dilated left atrium. No differences between propafenone and amiodarone on the prespecified short- and long-term outcomes were observed.
- MeSH
- amiodaron * terapeutické užití MeSH
- antiarytmika terapeutické užití MeSH
- fibrilace síní * terapie MeSH
- funkce levé komory srdeční MeSH
- lidé MeSH
- propafenon terapeutické užití MeSH
- prospektivní studie MeSH
- septický šok * komplikace farmakoterapie MeSH
- tepový objem MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
PURPOSE: The objective of our study was to evaluate the diagnostic accuracy of internal jugular vein (IJV) collapsibility as a predictor of fluid responsiveness in spontaneously breathing patients after cardiac surgery. METHODS: In this prospective observational study, spontaneously breathing patients were enrolled on the first postoperative day after coronary artery bypass grafting. Hemodynamic data coupled with simultaneous ultrasound assessment of the IJV were collected at baseline and after passive leg raising test (PLR). Continuous cardiac index (CI), stroke volume (SV), and stroke volume variation (SVV) were assessed with FloTracTM/EV1000TM. Fluid responsiveness was defined as an increase in CI ≥ 10% after PLR. We compared the differences in measured variables between fluid responders and non-responders and tested the ability of ultrasonographic IJV indices to predict fluid responsiveness. RESULTS: Fifty-four patients were included in the study. Seventeen (31.5%) were fluid responders. The responders demonstrated significantly lower inspiratory and expiratory diameters of the IJV at baseline, but IJV collapsibility was comparable (P = 0.7). Using the cut-off point of 20%, IJV collapsibility predicted fluid responsiveness with a sensitivity of 76.5% and specificity of 38.9%, ROC AUC 0.55. CONCLUSION: In spontaneously breathing patients after surgical coronary revascularisation, collapsibility of the internal jugular vein did not predict fluid responsiveness.
- MeSH
- dýchání MeSH
- hemodynamika MeSH
- kardiochirurgické výkony * MeSH
- lidé MeSH
- tekutinová terapie MeSH
- tepový objem MeSH
- venae jugulares * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
- MeSH
- lidé MeSH
- náhlé příhody MeSH
- péče o pacienty v kritickém stavu * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH
End-expiratory occlusion (EEO) and end-inspiratory occlusion (EIO) tests have been successfully used to predict fluid responsiveness in various settings using calibrated pulse contour analysis and echocardiography. The aim of this study was to test if respiratory occlusion tests predicted fluid responsiveness reliably in cardiac surgical patients with protective ventilation. This single-centre, prospective study, included 57 ventilated patients after elective coronary artery bypass grafting who were indicated for fluid expansion. Baseline echocardiographic measurements were obtained and patients with significant cardiac pathology were excluded. Cardiac index (CI), stroke volume and stroke volume variation were recorded using uncalibrated pulse contour analysis at baseline, after performing EEO and EIO tests and after volume expansion (7 mL/kg of succinylated gelatin). Fluid responsiveness was defined as an increase in cardiac index by 15%. Neither EEO, EIO nor their combination predicted fluid responsiveness reliably in our study. After a combined EEO and EIO, a cut-off point for CI change of 16.7% predicted fluid responsiveness with a sensitivity of 61.8%, specificity of 69.6% and ROC AUC of 0.593. In elective cardiac surgical patients with protective ventilation, respiratory occlusion tests failed to predict fluid responsiveness using uncalibrated pulse contour analysis.
- Publikační typ
- časopisecké články MeSH
BACKGROUND: The role of chest drain (CD) location by bedside imaging methods in the diagnosis of pneumothorax has not been explored in a prospective study yet. METHODS: Covid-19 ARDS patients with pneumothorax were prospectively monitored with chest ultrasound (CUS) and antero-posterior X-ray (CR) performed after drainage in the safe triangle. CD foreshortening was estimated as a decrease of chest drain index (CDI = length of CD in chest taken from CR/depth of insertion on CD scale + 5 cm). The angle of inclination of the CD was measured between the horizontal line and the CD at the point where it enters pleural space on CR. RESULTS: Of the total 106 pneumothorax cases 80 patients had full lung expansion on CUS, the CD was located by CUS in 69 (86%), the CDI was 0.99 (0.88-1.06). 26 cases had a residual pneumothorax after drainage (24.5%), the CD was located by CUS in 31%, the CDI was 0.76 (0.6-0.93),p < 0.01. The risk ratio for a pneumothorax in a patient with not visible CD between the pleural layers on CUS and an associated low CDI on CR was 5.97, p˂0.0001. For the patients with a steep angle of inclination (> 50°) of the CD, the risk ratio for pneumothorax was not significant (p < 0.17). A continued air leak from the CD after drainage is related to the risk for a residual pneumothorax (RR 2.27, p = 0.003). CONCLUSION: Absence of a CD on CUS post drainage, low CDI on CR and continuous air leak significantly associate with residual occult pneumothorax which may evade diagnosis on an antero-posterior CR.
- Publikační typ
- časopisecké články MeSH
- MeSH
- drenáž MeSH
- dýchací soustava MeSH
- lidé MeSH
- mimotělní membránová oxygenace * MeSH
- pleurální výpotek * diagnostické zobrazování terapie MeSH
- ultrasonografie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- dopisy MeSH
Kardioanesteziologie a pooperační péče v kardiochirurgii má svá specifika, která ji odlišují od ostatních oborů. Poslední dva roky poznamenané pandemií covidu-19 byly spojeny s útlumem kardiochirurgické elektivní operativy. V současnosti dochází opět ke zvýšení počtu operačních výkonů. Jsou testovány nové léky, publikovány nové doporučené postupy, jsou prováděny inovativní a hybridní operační postupy, které mají za cíl snížit invazivitu pro pacienta. Cílem tohoto přehledu je představit čtenářům důležité výstupy publikací týkajících se kardioanestezie, pooperační péče v kardiochirurgii a použití mimotělních podpor oběhu za poslední rok.
Cardiac anesthesia and postoperative care in cardiac surgery have their specifics, which differ from other specialties. The last two years marked by the COVID-19 pandemic were associated with a slowdown in elective cardiac surgery. Currently, the number of procedures is increasing again. New drugs are tested, new guidelines are published, innovative and hybrid procedures are performed, with the goal of reducing invasiveness for the patients. The aim of this review is to present readers with the important outputs of publications related to cardiac anesthesia, postoperative care in cardiac surgery, and the use of extracorporeal circulatory support over the past year.
- MeSH
- anestezie v kardiochirurgii * MeSH
- kardiochirurgické výkony MeSH
- lidé MeSH
- monitorování fyziologických funkcí MeSH
- pooperační péče * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
- přehledy MeSH
The hypodynamic septic shock appears to be a promising indication to veno-arterial membrane oxygenation (VA-ECMO) support of a patient with insufficient cardiac output. With cardiac recovery most of those patients progress into a hyperdynamic septic shock with cardiac output, which may not match critically low systemic vascular resistance to maintain perfusion pressures. Such refractory distributive shock represents a challenging indication to VA-ECMO. We report a rare case of a 27-year old patient who developed severe refractory hypodynamic septic shock due to the bilateral staphylococcal pneumonia and had to be initially rescued by femoro-femoral VA-ECMO. Despite extensive measures, he remained in intractable hypotension and profound tissue hypoperfusion with imminent multiorgan failure. The commencement of a second jugulo-axillary VA ECMO secured a total blood flow of 14.3 L/min, which restored perfusion pressure and successfully bridged patient over the period of critical haemodynamic instability and ultimately may have facilitated recovery.