OBJECTIVES: The aim of this study was to assess if prior oral anticoagulant agent (OAC) use modifies the lower bleeding risk observed with dabigatran dual therapy (dabigatran twice daily plus a P2Y12 inhibitor) versus warfarin triple therapy (warfarin plus a P2Y12 inhibitor plus aspirin) in patients with atrial fibrillation who underwent percutaneous coronary intervention (PCI). BACKGROUND: In the RE-DUAL PCI (Randomized Evaluation of Dual Antithrombotic Therapy With Dabigatran Versus Triple Therapy With Warfarin in Patients With Nonvalvular Atrial Fibrillation Undergoing Percutaneous Coronary Intervention) trial, the primary outcome of major bleeding or clinically relevant nonmajor bleeding was lower with dabigatran dual therapy versus warfarin triple therapy in patients with atrial fibrillation who underwent PCI. METHODS: A total of 2,725 patients were randomized to dual therapy with dabigatran (110 or 150 mg twice daily) plus clopidogrel or ticagrelor or triple therapy with warfarin plus aspirin and clopidogrel or ticagrelor. Subgroup analysis compared risk for major bleeding or clinically relevant nonmajor bleeding and a composite thromboembolic endpoint in patients with prior OAC use and in those who were OAC treatment naive. RESULTS: Risk for major bleeding or clinically relevant nonmajor bleeding was reduced with both dabigatran dual therapies compared with warfarin triple therapy in both the prior OAC use group (hazard ratios: 0.58 [95% confidence interval (CI): 0.42 to 0.81] and 0.61 [95% CI: 0.41 to 0.92] with 110 and 150 mg dabigatran, respectively) and the OAC-naive group (hazard ratios: 0.49 [95% CI: 0.38 to 0.63] and 0.76 [95% CI: 0.59 to 0.97] with 110 and 150 mg dabigatran) (p for interaction = 0.42 and 0.37, 110 and 150 mg dabigatran, respectively). The risk for thromboembolic events seemed similar with dabigatran dual therapy (both doses) and warfarin triple therapy across subgroups. CONCLUSIONS: Bleeding risk was reduced with dabigatran dual therapy versus warfarin triple therapy in patients with atrial fibrillation after PCI, regardless of whether they were prior OAC users or OAC treatment naive. These results suggest that it is also safe to switch patients on OAC pre-PCI to dabigatran dual therapy post-PCI.
- Klíčová slova
- OAC, atrial fibrillation, bleeding event, dabigatran dual therapy, oral anticoagulant agents, switching OACs,
- MeSH
- antikoagulancia aplikace a dávkování škodlivé účinky MeSH
- aplikace orální MeSH
- Aspirin aplikace a dávkování MeSH
- časové faktory MeSH
- dabigatran aplikace a dávkování MeSH
- fibrilace síní diagnóza farmakoterapie mortalita MeSH
- inhibitory agregace trombocytů aplikace a dávkování škodlivé účinky MeSH
- klopidogrel aplikace a dávkování MeSH
- kombinovaná farmakoterapie MeSH
- koronární angioplastika * škodlivé účinky mortalita MeSH
- krvácení chemicky indukované diagnóza MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhrada léků * škodlivé účinky MeSH
- nemoci koronárních tepen diagnostické zobrazování mortalita terapie MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ticagrelor aplikace a dávkování MeSH
- výsledek terapie MeSH
- warfarin aplikace a dávkování MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
- Názvy látek
- antikoagulancia MeSH
- Aspirin MeSH
- dabigatran MeSH
- inhibitory agregace trombocytů MeSH
- klopidogrel MeSH
- ticagrelor MeSH
- warfarin MeSH
AIMS: The subcutaneous implantable cardioverter defibrillator (S-ICD) was introduced to overcome complications related to transvenous leads. Adoption of the S-ICD requires implanters to learn a new implantation technique. The aim of this study was to assess the learning curve for S-ICD implanters with respect to implant-related complications, procedure time, and inappropriate shocks (IASs). METHODS AND RESULTS: In a pooled cohort from two clinical S-ICD databases, the IDE Trial and the EFFORTLESS Registry, complications, IASs at 180 days follow-up and implant procedure duration were assessed. Patients were grouped in quartiles based on experience of the implanter and Kaplan-Meier estimates of complication and IAS rates were calculated. A total of 882 patients implanted in 61 centres by 107 implanters with a median of 4 implants (IQR 1,8) were analysed. There were a total of 59 patients with complications and 48 patients with IAS. The complication rate decreased significantly from 9.8% in Quartile 1 (least experience) to 5.4% in Quartile 4 (most experience) (P = 0.02) and non-significantly for IAS from 7.9 to 4.8% (P = 0.10). Multivariable analysis demonstrated a hazard ratio of 0.78 (P = 0.045) for complications and 1.01 (P = 0.958) for IAS. Dual-zone programming increased with experience of the individual implanter (P < 0.001), which reduced IAS significantly in the multivariable model (HR 0.44, P = 0.01). Procedure time decreased from 75 to 65 min (P < 0.001). The complication rate and procedure time stabilized after Quartile 2 (>13 implants). CONCLUSION: There is a short and significant learning curve associated with physicians adopting the S-ICD. Performance stabilizes after 13 implants.
- Klíčová slova
- Complications, Implantable cardioverter-defibrillator, Inappropriate shock, Learning curve, S-ICD, Subcutaneous implantable cardioverter-defibrillator,
- MeSH
- databáze faktografické MeSH
- defibrilátory implantabilní * MeSH
- dospělí MeSH
- elektrická defibrilace * MeSH
- implantace protézy výchova MeSH
- Kaplanův-Meierův odhad MeSH
- kardiochirurgické výkony výchova MeSH
- křivka učení * MeSH
- lidé středního věku MeSH
- lidé MeSH
- multivariační analýza MeSH
- následné studie MeSH
- proporcionální rizikové modely MeSH
- registrace MeSH
- rizikové faktory MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) provides an alternative to the transvenous implantable cardioverter-defibrillator (TV-ICD). Patients undergoing TV-ICD explantation may be eligible for reimplantation with an S-ICD; however, information on safety outcomes in this complex population is limited. OBJECTIVE: This analysis was designed to provide outcome and safety data from S-ICD patients who received their device after TV-ICD explantation. METHODS: Patients in the S-ICD IDE Study and EFFORTLESS Registry with a prior TV-ICD explantation, as well as those with no prior implantable cardioverter-defibrillator (ICD), were included. Patients were divided into 3 groups: those implanted with the S-ICD after TV-ICD extraction for system-related infection (n = 75); those implanted after TV-ICD extraction for reasons other than system-related infection (n = 44); and patients with no prior ICD (de novo implantations, n = 747). RESULTS: Mean follow-up duration was 651 days, and all-cause mortality was low (3.2%). Patients previously explanted for TV-ICD infection were older (55.5 ± 14.6, 47.8 ± 14.3 and 49.9 ± 17.3 years in the infection, noninfection, and de novo cohorts, respectively; P = .01), were more likely to have received the ICD for secondary prevention (42.7%, 37.2% and 25.6%; P < 0.0001) and had higher percentages of comorbidities, including atrial fibrillation, congestive heart failure, diabetes mellitus, and hypertension, in line with the highest mortality rate (6.7%). Major infection after S-ICD implantation was low in all groups, with no evidence that patients implanted with the S-ICD after TV-ICD explantation for infection were more likely to experience a subsequent reinfection. CONCLUSION: The S-ICD is a suitable alternative for TV-ICD patients whose devices are explanted for any reason. Postimplantation risk of infection remains low even in patients whose devices were explanted for prior TV-ICD infection.
- Klíčová slova
- Death, Infection, Safety, Subcutaneous ICD, sudden,
- MeSH
- analýza přežití MeSH
- defibrilátory implantabilní * škodlivé účinky statistika a číselné údaje MeSH
- dospělí MeSH
- elektrická defibrilace přístrojové vybavení metody MeSH
- implantace protézy * škodlivé účinky metody mortalita MeSH
- infekce chirurgické rány * diagnóza epidemiologie terapie MeSH
- komorová tachykardie terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- reoperace statistika a číselné údaje MeSH
- selhání zařízení statistika a číselné údaje MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
AIMS: The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large international patient population collected as part of the EFFORTLESS S-ICD Registry. METHODS AND RESULTS: The EFFORTLESS S-ICD Registry is a non-randomized, standard of care, multicentre Registry designed to collect long-term, system-related, clinical, and patient reported outcome data from S-ICD implanted patients since June 2009. Follow-up data are systematically collected over 60-month post-implant including Quality of Life. The study population of 472 patients of which 241 (51%) were enrolled prospectively has a mean follow-up duration of 558 days (range 13-1342 days, median 498 days), 72% male, mean age of 49 ± 18 years (range 9-88 years), 42% mean left ventricular ejection fraction. Complication-free rates were 97 and 94%, at 30 and 360 days, respectively. Three hundred and seventeen spontaneous episodes were recorded in 85 patients during the follow-up period. Of these episodes, 169 (53%) received therapy, 93 being for Ventricular Tachycardia/Fibrillation (VT/VF). One patient died of recurrent VF and severe bradycardia. Regarding discrete VT/VF episodes, first shock conversion efficacy was 88% with 100% overall successful clinical conversion after a maximum of five shocks. The 360-day inappropriate shock rate was 7% with the vast majority occurring for oversensing (62/73 episodes), primarily of cardiac signals (94% of oversensed episodes). CONCLUSION: The first large cohort of real-world data from an International patient S-ICD population demonstrates appropriate system performance with clinical event rates and inappropriate shock rates comparable with those reported for conventional ICDs. Clinical trial registration URL: http://www.clinicaltrials.gov. Unique identifier NCT01085435.
- Klíčová slova
- Cardiac arrest, Primary prevention, Secondary prevention, Subcutaneous ICD, Ventricular arrhythmias,
- MeSH
- čas zasáhnout při rozvinutí nemoci MeSH
- defibrilátory implantabilní škodlivé účinky normy statistika a číselné údaje MeSH
- dítě MeSH
- dospělí MeSH
- implantace protézy metody MeSH
- kvalita života MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- prospektivní studie MeSH
- registrace MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- srdeční arytmie terapie MeSH
- výsledek terapie MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH