BACKGROUND: The same principle behind pulse wave analysis can be applied on the pulmonary artery (PA) pressure waveform to estimate right ventricle stroke volume (RVSV). However, the PA pressure waveform might be influenced by the direct transmission of the intrathoracic pressure changes throughout the respiratory cycle caused by mechanical ventilation (MV), potentially impacting the reliability of PA pulse wave analysis (PAPWA). We assessed a new method that minimizes the direct effect of the MV on continuous PA pressure measurements and enhances the reliability of PAPWA in tracking beat-to-beat RVSV. METHODS: Continuous PA pressure and flow were simultaneously measured for 2-3 min in 5 pigs using a high-fidelity micro-tip catheter and a transonic flow sensor around the PA trunk, both pre and post an experimental ARDS model. RVSV was estimated by PAPWA indexes such as pulse pressure (SVPP), systolic area (SVSystAUC) and standard deviation (SVSD) beat-to-beat from both corrected and non-corrected PA signals. The reference RVSV was derived from the PA flow signal (SVref). RESULTS: The reliability of PAPWA in tracking RVSV on a beat-to-beat basis was enhanced after accounting for the direct impact of intrathoracic pressure changes induced by MV throughout the respiratory cycle. This was evidenced by an increase in the correlation between SVref and RVSV estimated by PAPWA under healthy conditions: rho between SVref and non-corrected SVSD - 0.111 (0.342), corrected SVSD 0.876 (0.130), non-corrected SVSystAUC 0.543 (0.141) and corrected SVSystAUC 0.923 (0.050). Following ARDS, correlations were SVref and non-corrected SVSD - 0.033 (0.262), corrected SVSD 0.839 (0.077), non-corrected SVSystAUC 0.483 (0.114) and corrected SVSystAUC 0.928 (0.026). Correction also led to reduced limits of agreement between SVref and SVSD and SVSystAUC in the two evaluated conditions. CONCLUSIONS: In our experimental model, we confirmed that correcting for mechanical ventilation induced changes during the respiratory cycle improves the performance of PAPWA for beat-to-beat estimation of RVSV compared to uncorrected measurements. This was demonstrated by a better correlation and agreement between the actual SV and the obtained from PAPWA.
- Klíčová slova
- Fluid responsiveness, Heart lung interactions, Mechanical ventilation, Pulse wave analysis, Right ventricle, Stroke volume,
- Publikační typ
- časopisecké články MeSH
BACKGROUND: We studied a novel approach for the evaluation and management of volemia: minimally invasive monitoring of respiratory blood flow variations in the superior vena cava (SVC). We performed an experiment with 10 crossbred (Landrace × large white) female pigs (Sus scrofa domestica). METHODS: Hypovolemia was induced by bleeding from a femoral artery, in six stages. This was followed by blood return and then an infusion of 1000 ml saline, resulting in hypervolemia. Flow in the SVC was measured by Flowire (Volcano corp., USA), located in a distal channel of a triple-lumen central venous catheter. The key parameters measured were venous return variation index (VRV)-a new index for fluid responsiveness, calculated from the maximal and minimal velocity time intervals during controlled ventilation-and systolic peak velocity (defined as peak velocity of a systolic wave using the final end-expiratory beat). A Swan-Ganz catheter (Edwards Lifesciences, USA) was introduced into the pulmonary artery to measure pulmonary arterial pressure, pulmonary capillary wedge pressure, and continuous cardiac output measurements, using the Vigilance monitor (Edwards Lifesciences, USA). RESULTS: We analyzed 44 VRV index measurements during defined hemodynamic status events. The curves of VRV indexes for volume responders and volume non-responders intersected at a VRV value of 27, with 10% false negativity and 2% false positivity. We compared the accuracy of VRV and pulse pressure variations (PPV) for separation of fluid responders and fluid non-responders using receiver operating characteristic (ROC) curves. VRV was better (AUCROC 0.96) than PPV (AUCROC 0.85) for identification of fluid responders. The VRV index exhibited the highest relative change during both hypovolemia and hypervolemia, compared to standard hemodynamic measurement. CONCLUSIONS: The VRV index provides a real-time method for continuous assessment of fluid responsiveness. It combines the advantages of echocardiography-based methods with a direct and continuous assessment of right ventricular filling during mechanical ventilation.
- Klíčová slova
- Animal experiment, Flow measurement, Fluid responsiveness, Hemodynamics, Hypovolemia, Superior vena cava,
- Publikační typ
- časopisecké články MeSH