Nejvíce citovaný článek - PubMed ID 15662298
PURPOSE: The purpose of this study was to evaluate the long-term clinical and radiographic outcomes of the Balgrist total hip replacement cup. METHODS: We report the results of a retrospective review of 195 total hip prostheses with Balgrist cup implanted in 178 patients. There were 59 men and 119 women with a mean age at surgery of 52.3 years (range, 19-72). Cox regression was used to determine the influence of independent variables on the survivorship of the prosthesis. RESULTS: There were 117 (66 %) of 178 patients, and 131 (67 %) of 195 hips available for assessment at a mean follow-up of 17.4 years. A total of 21 patients (22 hips) were lost from follow-up (12 %). A total of 25 patients (27 hips) required some type of re-operation during the follow-up period. Eight of 27 re-operations (30 %) were directly caused by the Balgrist cup failure due to fatigue fracture of the metallic shell (n = 5; 19 %), polyethylene wear (n = 2; 7 %) and aseptic loosening (n = 1; 4 %). The mean polyethylene wear rate was 0.068 mm/year (range, 0.008-0.230; SD = 0.043). The risk of re-operation for any reason was decreased with dysplastic hip as a primary diagnosis (hazard ratio; HR = 0.250; 95 % CI 0.086-0.725) and with greater age at the time of surgery (HR = 0.923; 95 % CI 0.880-0.969). The 19-year survivorship with re-operation for any reason was 75.6 % (95 % CI 67.0-84.2). The 19-year survivorship with re-operation for the Balgrist cup failure was 90.5 % (95 % CI 83.4-97.6). CONCLUSIONS: The Balgrist cup continues to provide excellent clinical and radiological outcomes. This is associated at least in part with a low polyethylene wear rate. The main reason for the Balgrist cup failure is fatigue fracture of the metallic shell.
- MeSH
- artróza kyčelních kloubů chirurgie MeSH
- dospělí MeSH
- incidence MeSH
- Kaplanův-Meierův odhad MeSH
- kohortové studie MeSH
- kostní cementy MeSH
- kyčelní kloub diagnostické zobrazování chirurgie MeSH
- kyčelní protézy * MeSH
- lidé středního věku MeSH
- lidé MeSH
- longitudinální studie MeSH
- luxace kyčle chirurgie MeSH
- náhrada kyčelního kloubu přístrojové vybavení MeSH
- následné studie MeSH
- polyethylen MeSH
- proporcionální rizikové modely MeSH
- protézy - design * MeSH
- radiografie MeSH
- reoperace přístrojové vybavení statistika a číselné údaje MeSH
- retrospektivní studie MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
- Názvy látek
- kostní cementy MeSH
- polyethylen MeSH