Nejvíce citovaný článek - PubMed ID 22283108
Daily prostate volume and position monitoring using implanted gold markers and on-board imaging during radiotherapy
The purpose of this study was to compare two different styles of prostate IGRT: bony landmark (BL) setup vs. fiducial markers (FM) setup. Twenty-nine prostate patients were treated with daily BL setup and 30 patients with daily FM setup. Delivered dose distribution was reconstructed on cone-beam CT (CBCT) acquired once a week immediately after the alignment. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed 1 cm safety margin. Alternative plans assuming smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with initial ones. While the margin reduction in case of BL setup makes the prostate coverage significantly worse (p = 0.0003, McNemar's test), in case of FM setup with the reduced 7 mm margin, the prostate coverage is even better compared to BL setup with 10 mm margin (p = 0.049, Fisher's exact test). Moreover, partial volumes of organs at risk irradiated with a specific dose can be significantly lowered (p < 0.0001, unpaired t-test). Reducing of safety margin is not acceptable in case of BL setup, while the margin can be lowered from 10 mm to 7 mm in case of FM setup.
- MeSH
- adenokarcinom radioterapie MeSH
- celková dávka radioterapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- nádory prostaty radioterapie MeSH
- plánování radioterapie pomocí počítače MeSH
- počítačová tomografie s kuželovým svazkem statistika a číselné údaje MeSH
- radioterapie řízená obrazem * MeSH
- senioři MeSH
- staging nádorů MeSH
- zaměřovací značky pro radioterapii * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
AIM: To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. BACKGROUND: Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. MATERIALS AND METHODS: Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed. RESULTS: In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. CONCLUSION: Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.
- Klíčová slova
- Cone-beam computed tomography, Dose reconstruction, Dose-volume histogram, Image-guided radiotherapy, Prostate,
- Publikační typ
- časopisecké články MeSH