Nejvíce citovaný článek - PubMed ID 25813236
Determination of methicillin-resistant and methicillin-susceptible Staphylococcus aureus bacteria in blood by capillary zone electrophoresis
The properties of staphylococcal phages from the Siphoviridae, Podoviridae, and Myoviridae families were monitored using capillary electrophoretic methods on fused-silica capillaries with different morphology of surface roughness. Isoelectric points of the examined phages were determined by capillary isoelectric focusing in the original, smooth fused-silica capillary, and they ranged from 3.30 to 3.85. For capillary electrophoresis of phages, fused-silica capillaries with the "pock" and "cone" roughened surface types were prepared by etching a part of the capillary with supercritical water. The best resolution of the individual phages (to range from 3.2 to 4.6) was achieved with the "cone" surface-type fused-silica capillary. Direct application of phage K1/420 at the infection site, represented by human plasma or full blood spiked with Staphylococcus aureus, was on-line monitored by micellar electrokinetic chromatography. The phage particles were dynamically adhered onto the roughened surface of the capillary from 10 μL of the prepared sample at the optimized flow rate of 6.5 μL min-1. The limit of detection was determined to be 104 phage particles. The linearity of the calibration lines was characterized by the regression coefficient, R2 = 0.998. The relative standard deviation (RSD) of the peak area, calculated from ten independent measurements, was (±) 2%. After analysis, viability of the detected phages was verified by the modified "double-layer drop assay" method, and collected phage fractions were simultaneously off-line analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Graphical abstract.
- Klíčová slova
- Capillary electrophoresis, MALDI-TOF mass spectrometry, Nano-etched fused-silica capillary, Phage propagation, Staphylococcal bacteriophages, Supercritical water,
- MeSH
- bakteriofágy patogenita MeSH
- lidé MeSH
- odběr vzorku krve přístrojové vybavení MeSH
- oxid křemičitý chemie MeSH
- spektrometrie hmotnostní - ionizace laserem za účasti matrice metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- oxid křemičitý MeSH
The methicillin-resistant Staphylococcus aureus causes difficult-to-treat healthcare-associated infections in humans. For fast and effective selection of an appropriate antibiotic therapy, it is essential to have rapid and reliable methods for differentiation of methicillin-resistant S. aureus from less dangerous methicillin-sensitive S. aureus. There have been many methods for the identification of methicillin-resistant S. aureus described but none has been accepted as an international standard. The most commonly used techniques such as phenotyping and genotyping have a few disadvantages, for instance, these techniques are not reproducible and stable. In addition, they are time-consuming, expensive, and they are not capable to distinguish all S. aureus strains. In this study, the methicillin-resistant and methicillin-sensitive S. aureus isolates obtained from patients were extracted in hot water. The released proteins were characterised by sodium dodecyl sulphate polyacrylamide gel electrophoresis and gel isoelectric focusing. These two methods were able to differentiate among tested bacterial strains. The proposed methods are time saving, they are applicable in standard biochemical laboratories, and they do not require any expensive equipment.
- MeSH
- bakteriologické techniky metody MeSH
- časové faktory MeSH
- elektroforéza v polyakrylamidovém gelu metody MeSH
- isoelektrická fokusace metody MeSH
- lidé MeSH
- rezistence na methicilin * MeSH
- Staphylococcus aureus chemie klasifikace MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH