Nejvíce citovaný článek - PubMed ID 25896128
Neointimal coverage and late apposition of everolimus-eluting bioresorbable scaffolds implanted in the acute phase of myocardial infarction: OCT data from the PRAGUE-19 study
BACKGROUND: Bioresorbable scaffold (BRS) Absorb™ clinical use has been stopped due to higher rate of device thrombosis. Scaffold struts persist longer than 2 years in the vessel wall. Second generation devices are being developed. This study evaluates long-term invasive imaging in STEMI patients. METHODS: PRAGUE-19 study is an academic study enrolling consecutive STEMI patients with intention to implant Absorb™ BRS. A total of 83 STEMI patients between December 2012 and March 2014 fulfilled entry criteria. Coronary angiography and optical coherence tomography at 5 year follow-up was performed in 25 patients. RESULTS: Primary combined clinical endpoint (death, myocardial infarction or target vessel revascularization) occurred in 12.6% during the five-year follow-up with overall mortality 6.3%. Definite scaffold thrombosis occurred in 2 patients in the early phase after BRS implantation. Quantitative coronary angiography after 5 years demonstrated low late lumen loss of 0.11 ± 0.35 mm with binary restenosis rate of 0%. Optical coherence tomography demonstrated complete resorption of scaffold struts and mean lumen diameter of 3.25 ± 0.30 and 3.22 ± 0.49 (P = 0.73) at baseline and after 5 years, respectively. Three patients developed small coronary artery aneurysm in the treated segment. CONCLUSION: Invasive imaging results 5 years after BRS implantation in STEMI showed complete resorption of scaffold struts and stable lumen vessel diameter. Trial registration ISRCTN43696201 (retrospectivelly registred, June 7th, 2019). https://www.isrctn.com/ISRCTN43696201.
- Klíčová slova
- Bioresorbable scaffold, Long-term follow-up, Optical coherence tomography, Quantitative coronary angiography, STEMI,
- MeSH
- infarkt myokardu s elevacemi ST úseků * diagnostické zobrazování chirurgie MeSH
- koronární angiografie MeSH
- koronární angioplastika * MeSH
- lidé MeSH
- protézy - design MeSH
- stenty uvolňující léky * MeSH
- vstřebatelné implantáty MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- klinická studie MeSH
- práce podpořená grantem MeSH
A higher rate of bioresorbable vascular scaffold (BVS) thrombosis has been observed after device implantation compared to implantation of permanent metallic stents in recently published studies. The mechanism of BVS thrombosis is currently under debate. To assess whether the immune-inflammatory response after BVS implantation is a potential trigger of BVS thrombosis. The PRAGUE-19 study was an academic study that enrolled consecutive patients with ST-segment elevation myocardial infarction (STEMI) with the intention to implant a BVS. A laboratory sub-study included 49 patients with an implanted BVS (of which 38 underwent the complete 2-year follow-up) and 52 patients having an implanted permanent metallic stent as the control group (of which 30 underwent the complete 2-year follow-up). Samples for inflammatory markers [high-sensitivity C-reactive protein (hs-CRP), interleukin-6 (IL-6) and tumor necrosis factor-alpha (TNF-α)] were taken before BVS or stent implantation, on days 1 and 2 after device implantation and at 1 month and 2 years for a clinical control. The primary combined clinical endpoint of the sub-study (death, reinfarction or target vessel revascularization) occurred in 4.08% of the BVS group and 7.69% of the control group (p = 0.442) during the 2-year follow-up period, with overall mortality of 2.04% in the BVS group and 1.92% in the control group (p = 0.966). Definite BVS thrombosis occurred in one patient in the subacute phase; there was no late or very late thrombosis. Two definite stent thromboses were observed in the control group: one in the subacute phase and the other in the late phase. Baseline inflammatory marker levels did not differ between the groups. Lower levels of IL-6 and hs-CRP were observed in the BVS group compared to the control group (12.02 ± 5.94 vs. 15.21 ± 5.33 pg/ml; p < 0.01; 3952.9 ± 1704.75 ng/ml vs. 4507.49 ± 1190.01 ng/ml; p = 0.037, respectively) on days 1 and 2 (12.01 ± 6.31 vs. 13.85 ± 6.01 pg/ml; p = 0.089; 4447.92 ± 1325.31 ng/ml vs. 4637.03 ± 1290.99 ng/ml; p = 0.255, respectively). No differences in IL-6 or hs-CRP were observed after 1 month or 2 years in the clinical control. Levels of TNF-α did not differ between the groups in the early period after BVS or metallic stent implantation, nor during follow-up. The immune-inflammatory response is lower during the early phase after BVS implantation compared to that after metallic stent implantation, but the responses did not differ in the long term.
- Klíčová slova
- Bioresorbable vascular scaffold, Immune–inflammatory reaction, Myocardial infarction, Percutaneous coronary intervention, Thrombosis,
- MeSH
- časové faktory MeSH
- cytokiny metabolismus MeSH
- dospělí MeSH
- everolimus farmakologie MeSH
- imunosupresiva farmakologie MeSH
- infarkt myokardu s elevacemi ST úseků diagnóza imunologie chirurgie MeSH
- koronární angiografie MeSH
- koronární angioplastika přístrojové vybavení metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- přirozená imunita * MeSH
- protézy - design MeSH
- retrospektivní studie MeSH
- senioři MeSH
- stenty uvolňující léky * MeSH
- tkáňové podpůrné struktury * MeSH
- vstřebatelné implantáty * MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Názvy látek
- cytokiny MeSH
- everolimus MeSH
- imunosupresiva MeSH