Nejvíce citovaný článek - PubMed ID 27037563
Comparison of the efficacy of tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust™) in the treatment of female stress urinary incontinence: a 1-year follow-up randomized trial
INTRODUCTION: Single-incision miduretral slings (SIMS) were withdrawn from the market in many countries due to lower efficacy. In some countries they are still in use, preferred primarily because it is possible to perform the procedure under local anesthesia. Based on our previous clinical experience we postulated that local anesthesia decreased primary anchor fixation in the obturator complex. The aim of the study is to assess how local infiltration anesthesia influences anchor fixation of the tape in porcine obturator complex. METHODS: The experiment was designed to determine the maximum force necessary to extract an implant anchor from a porcine obturator complex. The implant was extracted at a constant speed and data sampling frequency, and the data on displacement of the testing system, achieved force and time were recorded. The implant arms were divided into groups on the right and left sides. In the first group, the anchored arms were used for two implantations - primary and secondary without infiltration anesthesia - and in the second group they were used in the same way, using infiltration anesthesia. RESULTS: A total of 40 implanted anchors were tested in the experiment, totaling ten single-incision slings (each anchor was implanted twice). An average of 8.28 N (Newton) (SD 6.73, min. 2.11, max. 30.34 N) is required to remove the implant anchor from the obturator complex without infiltration by local anesthesia. An average force of 4.40 N (SD 2.99 min. 1.2, max. 9.48) is required to remove the anchor from the obturator complex after infiltration. Local anesthesia reduces anchor fixation in the obturator complex by 47%. CONCLUSIONS: The local infiltrative anesthesia decreases anchor fixation in the porcine obturator complex.
- Klíčová slova
- Midurethral sling (MUS), Obturator complex, Single-incision midurethral sling (SIMS), Stress urinary incontinence, Trans-obturator tape,
- Publikační typ
- časopisecké články MeSH
INTRODUCTION AND HYPOTHESIS: The aim of this study was to assess the length of adjustable single-incision midurethral tape (SIMS; Ajust), which is needed to fix this tape to the obturator membrane. From these data, we can deduce the optimal length of the SIMS. METHODS: For this study, we employed the intra-operative data of patients included in a single-center randomized trial comparing the efficacy of Tension free vaginal tape obturator (TVT-O) and Ajust. The length of the Ajust tape was calculated using the formula: total length of the tape minus the length of the stylet used for the tape lock, minus the length of the lock minus the width of the two anchors. The length of the obturator tape was calculated using the formula: total tape length minus the snipped parts of the tape. The correlation coefficient of the tape length to basic biometric parameters, such as height, weight, and body mass index, was calculated. RESULTS: For this study, data from 50 women from each group, TVT-O and Ajust, were used. The mean length of the Ajust tape inside the body is 11.6 cm (SD 0.9), with a minimum length of 9.6 cm and a maximum length of 14.6 cm. The mean length of TVT-O tape inside the body is 20.3 cm (SD 2.1), with a minimum of 14.8 cm and a maximum length of 24.5 cm. CONCLUSIONS: This study demonstrates that to achieve continence it is necessary to use different lengths of single-incision tape. Inappropriate SIMS length could cause failure related to the tape itself and not to the TVT technique.
- Klíčová slova
- Ajust, Single-incision midurethral sling, Stress urinary incontinence, Surgical treatment, TVT-O,
- MeSH
- chirurgická rána MeSH
- lidé středního věku MeSH
- lidé MeSH
- senioři MeSH
- stresová inkontinence moči chirurgie MeSH
- suburetrální pásky * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
INTRODUCTION AND HYPOTHESIS: TVT-O production has been modified to laser cutting from mechanical cutting. We compared the behavior of laser and mechanically cut tension-free vaginal tape-obturator (TVT-O) using ultrasound at various time points after surgery. METHODS: This is a retrospective analysis of clinical and ultrasound data from two previously reported randomized controlled trials with TVT-O. Behavior of mechanically cut TVT-O implanted in January 2007 to November 2009 and laser-cut TVT-O implanted in May 2010 to May 2012 was assessed by ultrasound at day 1, the 2nd week, the 3rd month, and the 1st and 2nd years post-operatively. Bladder neck and tape margins positions were described by coordinates in the orthogonal system calculated from polar coordinates. Tape mobility was measured as a change in the upper and lower tape margin position from rest to maximal Valsalva. Comparison of 2-year subjective and objective surgery outcomes was also performed. RESULTS: In total, 68 mechanically cut and 50 laser-cut TVT-Os were implanted. Follow-up data were available from 49 and 45 women respectively. No differences in any baseline characteristics or bladder neck mobility were observed. Significantly lower tape mobility was observed on day 1 and week 2 after mechanically cut TVT-O, although subsequent mobility was comparable to laser-cut TVT-O. The subjective and objective surgery outcomes were comparable. CONCLUSIONS: Although without clinical significance, early postoperative behavior of the mechanically cut and laser-cut TVT-O tapes differs. The less stiff, mechanically-cut TVT-O loosens within 2 weeks of implantation, whereas the stiffer, laser-cut TVT-O keeps its tension.
- Klíčová slova
- TVT-O, Tape elongation properties, Tape mobility, Tape stiffness, Ultrasound,
- MeSH
- chirurgická páska * MeSH
- gynekologické chirurgické výkony přístrojové vybavení metody MeSH
- lidé MeSH
- močový měchýř MeSH
- pooperační období MeSH
- retrospektivní studie MeSH
- stresová inkontinence moči chirurgie MeSH
- suburetrální pásky * MeSH
- ultrasonografie * MeSH
- urologické chirurgické výkony metody MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH