Nejvíce citovaný článek - PubMed ID 29706574
Early detection of cardiac allograft vasculopathy using highly automated 3-dimensional optical coherence tomography analysis
BACKGROUND: There is conflicting evidence on the role of acetylsalicylic acid (ASA) use in the development of cardiac allograft vasculopathy (CAV). METHODS: A nationwide prospective two-center study investigated changes in the coronary artery vasculature by highly automated 3-D optical coherence tomography (OCT) analysis at 1 month and 12 months after heart transplant (HTx). The influence of ASA use on coronary artery microvascular changes was analyzed in the overall study cohort and after propensity score matching for selected clinical CAV risk factors. RESULTS: In total, 175 patients (mean age 52 ± 12 years, 79% male) were recruited. During the 1-year follow-up, both intimal and media thickness progressed, with ASA having no effect on its progression. However, detailed OCT analysis revealed that ASA use was associated with a lower increase in lipid plaque (LP) burden (p = .013), while it did not affect the other observed pathologies. Propensity score matching of 120 patients (60 patient pairs) showed similar results, with ASA use associated with lower progression of LPs (p = .002), while having no impact on layered fibrotic plaque (p = .224), calcification (p = .231), macrophage infiltration (p = .197), or the absolute coronary artery risk score (p = .277). According to Kaplan-Meier analysis, ASA use was not associated with a significant difference in survival (p = .699) CONCLUSION: This study showed a benefit of early ASA use after HTx on LP progression. However, ASA use did not have any impact on the progression of other OCT-observed pathologies or long-term survival.
- Klíčová slova
- OCT, acetylsalicylic acid, cardiac allograft vasculopathy, lipid plaque,
- MeSH
- alografty patologie MeSH
- aterosklerotický plát * komplikace MeSH
- dospělí MeSH
- koronární angiografie MeSH
- lidé středního věku MeSH
- lidé MeSH
- nemoci koronárních tepen * etiologie MeSH
- optická koherentní tomografie škodlivé účinky metody MeSH
- prospektivní studie MeSH
- transplantace srdce * škodlivé účinky MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH
Optical Coherence Tomography (OCT) is an intravascular imaging modality enabling detailed evaluation of cardiac allograft vasculopathy (CAV) after heart transplantation (HTx). However, its clinical application remains hampered by time-consuming manual quantitative analysis. We aimed to validate a semi-automated quantitative OCT analysis software (Iowa Coronary Wall Analyzer, ICWA-OCT) to improve OCT-analysis in HTx patients. 23 patients underwent OCT evaluation of all three major coronary arteries at 3 months (3M) and 12 months (12M) after HTx. We analyzed OCT recordings using the semiautomatic software and compared results with measurements from a validated manual software. For semi-automated analysis, 31,228 frames from 114 vessels were available. The validation was based on a subset of 4287 matched frames. We applied mixed model statistics to accommodate the multilevel data structure with method as a fixed effect. Lumen (minimum, mean, maximum) and media (mean, maximum) metrics showed no significant differences. Mean and maximum intima area were underestimated by the semi-automated method (β-methodmean = - 0.289 mm2, p < 0.01; β-methodmax = - 0.695 mm2, p < 0.01). Bland-Altman analyses showed increasing semi-automatic underestimation of intima measurements with increasing intimal extent. Comparing 3M to 12M progression between methods, mean intimal area showed minor underestimation (β-methodmean = - 1.03 mm2, p = 0.04). Lumen and media metrics showed excellent agreement between the manual and semi-automated method. Intima metrics and progressions from 3M to 12M were slightly underestimated by the semi-automated OCT software with unknown clinical relevance. The semi-automated software has the future potential to provide robust and time-saving evaluation of CAV progression.
- Klíčová slova
- Cardiac allograft vasculopathy, Heart transplantation, Intravascular imaging, Optical coherence tomography, Validation,
- MeSH
- koronární cévy MeSH
- lidé MeSH
- nemoci koronárních tepen * MeSH
- nemoci srdce * MeSH
- optická koherentní tomografie metody MeSH
- prediktivní hodnota testů MeSH
- software MeSH
- transplantace srdce * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Imaging-based characteristics associated with the progression of stable coronary atherosclerotic lesions are poorly defined. Utilizing a combination of optical coherence tomography (OCT) and intravascular ultrasound (IVUS) imaging, we aimed to characterize the lesions prone to progression through clinical validation of a semiautomated OCT computational program. METHODS: Patients with stable coronary artery disease underwent nonculprit vessel imaging with IVUS and OCT at baseline and IVUS at the 12-month follow-up. After coregistration of baseline and follow-up IVUS images, paired 5-mm segments from each patient were identified, demonstrating the greatest plaque progression and regression as measured by the change in plaque burden. Experienced readers identified plaque features on corresponding baseline OCT segments, and predictors of plaque progression were assessed by multivariable analysis. Each segment then underwent volumetric assessment of the fibrous cap (FC) using proprietary software. RESULTS: Among 23 patients (70% men; median age, 67 years), experienced-reader analysis demonstrated that for every 100 μm increase in mean FC thickness, plaques were 87% less likely to progress (P = .01), which persisted on multivariable analysis controlling for baseline plaque burden (P = .05). Automated FC analysis (n = 17 paired segments) confirmed this finding (P = .01) and found thinner minimal FC thickness (P = .01) and larger FC surface area of <65 μm (P = .02) and <100 μm (P = .04) in progressing segments than in regressing segments. No additional imaging features predicted plaque progression. CONCLUSIONS: A semiautomated FC analysis tool confirmed the significant association between thinner FC and stable coronary plaque progression along entire vessel segments, illustrating the diffuse nature of FC thinning and suggesting a future clinical role in predicting the progression of stable coronary artery disease.
- Klíčová slova
- coronary artery disease, intravascular ultrasound, optical coherence tomography,
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: Recent studies suggested potential positive correlations between HLA-specific antibodies and development of cardiac allograft vasculopathy (CAV). METHODS: This prospective two-center study investigated early progression of CAV by coronary optical coherence tomography in 1 month and 12 months after heart transplantation (HTx) in 104 patients. Detection and characterization of donor specific (DSA) and MHC class-I polypeptide-related sequence A (MICA) antibodies were performed before, 1, 6 and 12 months after transplantation. RESULTS: During the first post-HTx year, we observed a significant reduction in the mean coronary luminal area (P < .001), and progression in mean intimal thickness (IT) (P < .001). DSA and anti-MICA occurred in 17% of all patients, but no significant relationship was observed between presence of DSA/anti-MICA and IT progression within 12 months after HTx. In contrast, we observed significant association between presence of DSA (p=0.031), de-novo DSA (p=0.031), HLA Class II DSA (p=0.017) and media thickness (MT) progression. CONCLUSION: Results of our study did not identify a direct association between presence of DSA/anti-MICA and intimal thickness progression in an early period after HTx. However, we found significant relationships between DSA and media thickness progression that may identify a newly recognized immune-pathological aspect of CAV.
- Klíčová slova
- Cardiac allograft vasculopathy, Donor specific antibodies, Heart transplant, Intimal thickness,
- MeSH
- alografty MeSH
- dárci tkání MeSH
- HLA antigeny MeSH
- lidé MeSH
- optická koherentní tomografie * MeSH
- prospektivní studie MeSH
- rejekce štěpu diagnóza MeSH
- retrospektivní studie MeSH
- transplantace srdce * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH
- Názvy látek
- HLA antigeny MeSH
INTRODUCTION: Heart rate slowing agents are frequently prescribed to manage heart transplant (HTx) patients with the assumption that higher heart rate is a risk factor in cardiovascular disease. PATIENTS AND METHODS: This prospective two-center study investigated early progression of cardiac allograft vasculopathy (CAV) in 116 HTx patients. Examinations by coronary optical coherence tomography and 24-hour ambulatory ECG monitoring were performed both at baseline (1 month after HTx) and during follow-up (12 months after HTx). RESULTS: During the first post-HTx year, we observed a significant reduction in the mean coronary luminal area from 9.0 ± 2.5 to 8.0 ± 2.4 mm2 (P < .001), and progression in mean intimal thickness (IT) from 106.5 ± 40.4 to 130.1 ± 53.0 µm (P < .001). No significant relationship was observed between baseline and follow-up mean heart rates and IT progression (R = .02, P = .83; R = -.13, P = .18). We found a mild inverse association between beta-blocker dosage at 12 months and IT progression (R = -.20, P = .035). CONCLUSION: Our study did not confirm a direct association between mean heart rate and progression of CAV. The role of beta blockers warrants further investigation, with our results indicating that they may play a protective role in early CAV development.
- Klíčová slova
- beta blocker, cardiac allograft vasculopathy, heart rate, optical coherence tomography,
- MeSH
- alografty MeSH
- koronární angiografie MeSH
- lidé MeSH
- nemoci koronárních tepen * diagnostické zobrazování etiologie MeSH
- optická koherentní tomografie MeSH
- prospektivní studie MeSH
- srdeční frekvence MeSH
- transplantace srdce * škodlivé účinky MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH