Most cited article - PubMed ID 29788834
Echocardiography in extracorporeal life support: A key player in procedural guidance, tailoring and monitoring
Refractory septic shock is associated with a high risk of death. Circulatory support in the form of veno-arterial extracorporeal membrane oxygenation (VA ECMO) may function as a bridge to recovery, allowing for the treatment of the source of the sepsis. Whilst VA ECMO has been accepted as the means of hemodynamic support for children, in adults, single center observational studies show survival rates of only 70-90% for hypodynamic septic shock. The use of VA ECMO for circulatory support in hyperdynamic septic shock with preserved cardiac output or when applied late during cardio-pulmonary resuscitation is not recommended. With unresolving septic shock and a loss of ventriculo-arterial coupling, stress cardiomyopathy often develops. If the cardiac index (CI) approaches subnormal levels (CI < 2.5 L/min m-2) that do not match low systemic vascular resistance with a resulting loss of vital systemic perfusion pressure, VA ECMO support should be considered. A further decrease to the level of cardiogenic shock (CI < 1.8 L/min m-2) should be regarded as an indication for VA ECMO insertion. For patients who maintain a normal-to-high CI as part of their refractory vasoparalysis, VA ECMO support is justified in children and possibly in patients with a low body mass index. Extracorporeal support for septic shock should be limited to high-volume ECMO centers.
- Keywords
- cardiac output, distributive shock, extracorporeal membrane oxygenation, refractory vasoparalysis, septic shock, stress cardiomyopathy,
- Publication type
- Journal Article MeSH
- Review MeSH
BACKGROUND: Venoarterial extracorporeal membrane oxygenation (VA ECMO) is widely used in the treatment of circulatory failure, but repeatedly, its negative effects on the left ventricle (LV) have been observed. The purpose of this study is to assess the influence of increasing extracorporeal blood flow (EBF) on LV performance during VA ECMO therapy of decompensated chronic heart failure. METHODS: A porcine model of low-output chronic heart failure was developed by long-term fast cardiac pacing. Subsequently, under total anesthesia and artificial ventilation, VA ECMO was introduced to a total of five swine with profound signs of chronic cardiac decompensation. LV performance and organ specific parameters were recorded at different levels of EBF using a pulmonary artery catheter, a pressure-volume loop catheter positioned in the LV, and arterial flow probes on systemic arteries. RESULTS: Tachycardia-induced cardiomyopathy led to decompensated chronic heart failure with mean cardiac output of 2.9 ± 0.4 L/min, severe LV dilation, and systemic hypoperfusion. By increasing the EBF from minimal flow to 5 L/min, we observed a gradual increase of LV peak pressure from 49 ± 15 to 73 ± 11 mmHg (P = 0.001) and an improvement in organ perfusion. On the other hand, cardiac performance parameters revealed higher demands put on LV function: LV end-diastolic pressure increased from 7 ± 2 to 15 ± 3 mmHg, end-diastolic volume increased from 189 ± 26 to 218 ± 30 mL, end-systolic volume increased from 139 ± 17 to 167 ± 15 mL (all P < 0.001), and stroke work increased from 1434 ± 941 to 1892 ± 1036 mmHg*mL (P < 0.05). LV ejection fraction and isovolumetric contractility index did not change significantly. CONCLUSIONS: In decompensated chronic heart failure, excessive VA ECMO flow increases demands and has negative effects on the workload of LV. To protect the myocardium from harm, VA ECMO flow should be adjusted with respect to not only systemic perfusion, but also to LV parameters.
- Keywords
- Artificial cardiac pacing, Extracorporeal membrane oxygenation, Heart failure, Heart ventricles, Hemodynamics, Swine,
- MeSH
- Ventricular Function, Left MeSH
- Hemodynamics MeSH
- Extracorporeal Membrane Oxygenation * MeSH
- Myocardium MeSH
- Swine MeSH
- Heart Failure * therapy MeSH
- Animals MeSH
- Check Tag
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH