Most cited article - PubMed ID 38767244
A Modular Communicative Leadless Pacing-Defibrillator System
BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) investigated the efficacy and safety of the subcutaneous implantable cardioverter defibrillator (S-ICD) compared with a transvenous ICD (TV-ICD) and showed noninferiority of the S-ICD with regard to the composite end point of device-related complications and inappropriate shocks after 49.1 months. Complications associated with transvenous leads are expected to occur after longer follow-up. The PRAETORIAN-XL trial aims to investigate whether the S-ICD is superior to the TV-ICD with respect to device-related complications at 8-year follow-up. METHODS: The PRAETORIAN trial randomized patients with a class I or IIa indication for ICD therapy without the need for pacing to either S-ICD or TV-ICD among 39 centers in the United States and Europe between March 2011 and January 2017. The follow-up was extended after 49.1 months by an additional 4 years for the PRAETORIAN-XL trial. The primary end point was the composite of all device-related complications. Complications could be related or unrelated to the lead and minor or major, with major complications being those requiring an invasive intervention. End points were analyzed according to the modified intention-to-treat principle using a Fine-Gray subdistribution hazards model to account for competing risks. An as-treated analysis was performed using a Cox proportional hazards model with device type as time-dependent variable. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). Twenty-one percent of the S-ICD group versus 18% of the TV-ICD group were women. The median age at implantation was 63 (interquartile range, 54-69) years for the S-ICD and 64 (interquartile range, 56-69) years for the TV-ICD. After a median follow-up of 87.5 months, all device-related complications (major and minor combined) were not significantly different in the modified intention-to-treat analysis (subdistribution hazard ratio, 0.73 [95% CI, 0.48-1.12]); P=0.15). However, TV-ICD patients more often had a major complication or lead-related complication (P=0.03 and P<0.001, respectively). Moreover, the as-treated analysis showed significantly more complications in patients with a TV-ICD compared with an S-ICD (hazard ratio, 0.64 [95% CI, 0.41-0.99]; P=0.047). CONCLUSIONS: The PRAETORIAN-XL trial demonstrated that there was no significant difference between the S-ICD and TV-ICD in all device-related complications during long-term follow-up. However, the TV-ICD carries a higher risk of major and lead-related complications compared with S-ICD therapy. The S-ICD should therefore be considered for all patients without a pacing indication who are evaluated for ICD therapy. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.
- Keywords
- complications, defibrillators, implantable, electrophysiology,
- MeSH
- Time Factors MeSH
- Defibrillators, Implantable * adverse effects MeSH
- Electric Countershock * instrumentation adverse effects MeSH
- Middle Aged MeSH
- Humans MeSH
- Follow-Up Studies MeSH
- Prospective Studies MeSH
- Aged MeSH
- Treatment Outcome MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Multicenter Study MeSH
- Randomized Controlled Trial MeSH
- Comparative Study MeSH
Up to one-third of patients referred for transcatheter tricuspid valve intervention (TTVI) have a transvalvular pacemaker (PPM) or implantable cardioverter-defibrillator (ICD) lead in place. Both the electrophysiology and interventional cardiology communities have been alerted to the complexity of decision-making in this situation due to potential interactions between the leads and the TTVI material, including the risk of jailing or damage to the leads. This document, commissioned by the European Heart Rhythm Association and the European Association of Percutaneous Cardiovascular Interventions of the ESC, reviews the scientific evidence to inform Heart Team discussions on the management of patients with a PPM or ICD who are scheduled for or have undergone TTVI.
- Keywords
- Transcatheter tricuspid valve intervention, cardiac implantable electronic device lead, lead extraction, lead jailing, tricuspid regurgitation,
- MeSH
- Heart Valve Prosthesis Implantation * adverse effects standards methods instrumentation MeSH
- Defibrillators, Implantable * standards MeSH
- Pacemaker, Artificial * standards MeSH
- Consensus MeSH
- Humans MeSH
- Risk Factors MeSH
- Cardiac Catheterization * adverse effects standards instrumentation MeSH
- Tricuspid Valve * surgery physiopathology MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Practice Guideline MeSH