Nejvíce citovaný článek - PubMed ID 4923168
BACKGROUND: The exact positioning of the dominant hand at the time of manual perineal protection (MPP) is not clearly specified. The main aim of this work was to identify the place on the perineum where pressure needs to be applied to achieve optimal forward fetal head displacement away from the anal sphincters using the bregma to posterior fourchette distance (BFD) and the perineal body length (PBL). METHODS: This was a two-center prospective cohort study. Term cephalic singleton nulliparous women having spontaneous vaginal delivery were considered eligible for recruitment into the study. Once crowning was diagnosed and just prior the initiation of manual perineal protection (MPP) or cutting an episiotomy, the BFD and PBL were measured using a standardized measurement protocol. RESULTS AND DISCUSSION: A total of 100 women (50 women in each center) were recruited into the study. The overall mean BFD was 2.8 ± 0.5 cm. The overall mean PBL was 4.4 ± 0.8 cm. There were no statistically significant differences between the measurements taken in both units regarding BFD or PBL (p = 0.81 and 0.10 respectively). There was a weak correlation between both measurements. Based on our measured parameters, it seems that the most effective point to apply perineal pressure to displace the head away from the anus is approximately 1 - 1.5 cm anterior to the anal margin. CONCLUSION: Measurements generated by this study will form the bases of future biomechanical studies to confirm their validity.
- Klíčová slova
- Manual perineal protection, Perineal body, Perineal mapping, Perineal tension,
- MeSH
- anální kanál fyziologie MeSH
- dospělí MeSH
- epiziotomie * statistika a číselné údaje metody MeSH
- hlava * MeSH
- lidé MeSH
- mladý dospělý MeSH
- perineum * MeSH
- prospektivní studie MeSH
- těhotenství MeSH
- tlak MeSH
- vedení porodu metody MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
BACKGROUND: Manual perineal protection (MPP) is an intrapartum intervention suggested to protect perineal integrity during childbirth. Proper execution of MPP is complex and evaluation of its true contribution is difficult in the clinical setting because of the large number of obstetric variables, some of which are hardly quantifiable. In this study we aimed to gather initial data on the forces executed by the accoucheur's thumb, index and middle fingers during MPP at the time of fetal head expulsion, quantify the duration of the intervention and investigate the timely interaction of the different components of MPP. METHODS: Two bespoke right-handed measurement gloves (MG), with built in sensors, were designed and produced. The MG allowed the electronic real-time measurement of applied forces during MPP and transferred this data wirelessly to an integrated computer system. Sterile gloves were worn over the MG when used at the time of birth. The study was undertaken between January and December 2019. Singleton, term pregnant women having their first vaginal birth who provided a valid written consent were enrolled into this prospective pilot study. All deliveries were undertaken by one of two obstetricians experienced in MPP. RESULTS: Twenty women were enrolled. The mean duration of execution of MPP during the last contraction was 13.6 s. In 20% it lasted < 5 s. The overall mean values of the average and maximum forces of the thumb, index and middle fingers were 26.7 N; 25.5 N; 20.2 N and 34.3 N; 32.6 N; and 27.6 N respectively. The onset of fingers and thumb activity was simultaneous in 13 cases (65%), while in seven (35%) deliveries the middle finger's force activity was initiated later. CONCLUSIONS: MPP during fetal head expulsion happens over a short period of time. In the majority of cases the thumb and fingers actions started simultaneously. There were differences in the duration of application and the forces executed by the fingers and thumb between the two practitioners, however this was only significant for thumb measurements. The results obtained will aid in improving further MPP modeling studies to optimize the technique.
- Klíčová slova
- Computational modelling, Duration, Finnish method, Forces, Keys: Manual perineal protection, Physiology, Pressure, Vaginal delivery, Variability,
- MeSH
- benchmarking MeSH
- dospělí MeSH
- hlava MeSH
- lidé MeSH
- perineum fyziologie MeSH
- pilotní projekty MeSH
- prospektivní studie MeSH
- prsty ruky MeSH
- těhotenství MeSH
- vedení porodu přístrojové vybavení MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVE: The aim of this study was to evaluate whether a previously identified modification of Viennese method of perineal protection remains most effective for reduction of perineal tension in cases with substantially smaller or larger fetal heads. METHODS: A previously designed finite element model was used to compare perineal tension of different modifications of the Viennese method of perineal protection to "hands-off" technique for three different sizes of the fetal head. Quantity and extent of tension throughout the perineal body during vaginal delivery at the time when the suboccipito-bregmatic circumference passes between the fourchette and the lower margin of the pubis was determined. RESULTS: The order of effectiveness of different modifications of manual perineal protection was similar for all three sizes of fetal head. The reduction of perineal tension was most significant in delivery simulations with larger heads. The final position of fingers 2cm anteriorly from the fourchette (y = +2) consistently remains most effective in reducing the tension. The extent of finger movement along the anterior-posterior (y-axis) contributes to the effectiveness of manual perineal protection. CONCLUSION: Appropriately performed Viennese manual perineal protection seems to reduce the perineal tension regardless of the fetal head size, and thus the method seems to be applicable to reduce risk of perineal trauma for all parturients.
- MeSH
- analýza metodou konečných prvků MeSH
- hlava anatomie a histologie MeSH
- komplikace porodu prevence a kontrola MeSH
- lidé MeSH
- perineum zranění MeSH
- plod anatomie a histologie MeSH
- těhotenství MeSH
- vedení porodu škodlivé účinky metody MeSH
- Check Tag
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH