INTRODUCTION: En-bloc spondylectomy in the lumbar spine is a challenging procedure mainly due to a complex prevertebral anatomy. The aim of our study is to describe the anatomy of the diaphragmatic crura and surrounding vascular and neural structures which may be iatrogenically injured during the surgical resection. MATERIALS AND METHODS: Ten embalmed specimens were meticulously dissected. Widths of the diaphragmatic crura, abdominal aorta, cisterna chyli, thoracic duct, sympathetic trunks, and inferior vena cava as well as their distances from the midline were measured at nine levels (L1 to L4 vertebra and adjacent intervertebral discs). RESULTS: The right crus was attached to the L2-L4 vertebral bodies and L2/3 intervertebral disc, while the left crus inserted onto L1-L3 vertebrae. The thoracic duct arose commonly at the level of L2 vertebra and overlaid the right crus at the L3 vertebra and L2/3-disc levels. The cisterna chyli was present in 70% of specimens and overlapped with the left crus at the same levels. Both sympathetic trunks emerged underneath the crura at the L1/2 discs or L1 vertebra level. The aorta overlapped with the crura at all levels. CONCLUSION: The L3 level appears to be the riskiest for spondylectomy due to the overlap of both diaphragmatic crura with the thoracic duct and cisterna chyli, respectively. Spondylectomy at the L2 level also brings the risk of lymphatic structures injury while injury to the left sympathetic trunk may be the main issue at the L1 level.
- Klíčová slova
- Abdominal aorta, Cisterna chyli, Diaphragmatic crura, Sympathetic trunk, Thoracic duct, Total en bloc spondylectomy,
- Publikační typ
- časopisecké články MeSH
PURPOSE: The Core Outcome Measures Index (COMI) is a short, multidimensional instrument translated into several languages that covers five domains recommended in the assessment of outcome in patients with low-back and neck pain. The purpose of this study was to cross-culturally adapt the COMI from English to Czech language and to test the face and construct validity and reproducibility of its results in patients with low-back and neck pain. METHODS: Participants (n = 125) were included from primary and secondary care. The participants reported moderate pain and disability levels. All participants filled in the COMI forms before and after surgery. Descriptive statistics, Wilcoxon paired test, Crombach's alpha, principal component analysis and information entropy calculation were used. RESULTS: The instrument was successfully forward and back-translated. It can be seen that the questionnaire applied as part of our intervention study produces answers with a sufficient degree of variability and with a satisfactory degree of representation of extreme values. It can be also seen that the questionnaire can diagnose an objectively occurring change associated with the surgeon within the intervention procedure. Our other findings support the idea of a possible reduction in the number of questions that measure the same latent variable. Our investigations also showed that it is possible to reduce the range of the point scale of the perception of pain to 5 degrees of intensity and thus unify the range with the other questions. CONCLUSION: The Czech COMI shows acceptable properties and is thus suitable to use as a short instrument for measuring important domains in patients with low-back and neck pain.
- Klíčová slova
- Back pain, COMI forms, Czech translation, Neck pain, Spine Tango,
- MeSH
- bolest krku * diagnóza MeSH
- dospělí MeSH
- hodnocení výsledků zdravotní péče metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- lumbalgie * diagnóza MeSH
- měření bolesti metody MeSH
- posuzování pracovní neschopnosti MeSH
- průzkumy a dotazníky normy MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- srovnání kultur * MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Česká republika MeSH
BACKGROUND: A comparison of fusion rates and clinical outcomes of instrumented transforaminal interbody fusion (TLIF) between polyetheretherketone (PEEK) and titanium-coated PEEK (Ti-PEEK) cages is not well documented. METHODS: A single-centre, prospective, randomised study included patients who underwent one-level TLIF between L3-S1 segments. Patients were randomised into one of two groups: TLIF surgery with the PEEK cage and TLIF surgery with the Ti-PEEK cage. Clinical results were measured. All patients were assessed by repeated X-rays and 3D CT scans. Cage integration was assessed using a modified Bridwell classification. The impact of obesity and smoking on fusion quality was also analysed. Patients in both groups were followed up for 2 years. RESULTS: Altogether 87 patients were included in the study: of these 87 patients, 81 (93.1%) completed the 2-year follow-up. A significant improvement in clinical outcome was found in the two measurements scales in both groups (RM: p = 0.257, VAS: p = 0.229). There was an increase in CobbS and CobbL angle in both groups (p = 0.172 for CobbS and p = 0.403for CobbL). Bony fusion was achieved in 37 of 40 (92.5%) patients in the TiPEEK group and 35 of 41 (85.4%) in the PEEK group (p = 0.157). Cage subsided in 2 of 40 patients (5%) in the TiPEEK group and 11 of 41 (26.8%) in the PEEK group (p = 0.007). Body mass index > 30 and smoking were not predictive factors of bony fusion achievement. CONCLUSION: There is no significant advantage of TiPEEK cages over PEEK cages in clinical outcome and fusion rate 2 years after surgery.
- Klíčová slova
- Low back pain, Outcome measurements, Spinal fusion, Spine, Spondylolysis,
- MeSH
- bederní obratle chirurgie MeSH
- benzofenony * MeSH
- fúze páteře * metody MeSH
- ketony MeSH
- lidé MeSH
- polyethylenglykoly MeSH
- polymery * MeSH
- prospektivní studie MeSH
- titan * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
- Názvy látek
- benzofenony * MeSH
- ketony MeSH
- polyetheretherketone MeSH Prohlížeč
- polyethylenglykoly MeSH
- polymery * MeSH
- titan * MeSH
PURPOSE: Studies have shown that bracing is an effective treatment for patients with idiopathic scoliosis. According to the current classification, almost all braces fall in the thoracolumbosacral orthosis (TLSO) category. Consequently, the generalization of scientific results is either impossible or misleading. This study aims to produce a classification of the brace types. METHODS: Four scientific societies (SOSORT, SRS, ISPO, and POSNA) invited all their members to be part of the study. Six level 1 experts developed the initial classifications. At a consensus meeting with 26 other experts and societies' officials, thematic analysis and general discussion allowed to define the classification (minimum 80% agreement). The classification was applied to the braces published in the literature and officially approved by the 4 scientific societies and by ESPRM. RESULTS: The classification is based on the following classificatory items: anatomy (CTLSO, TLSO, LSO), rigidity (very rigid, rigid, elastic), primary corrective plane (frontal, sagittal, transverse, frontal & sagittal, frontal & transverse, sagittal & transverse, three-dimensional), construction-valves (monocot, bivalve, multisegmented), construction-closure (dorsal, lateral, ventral), and primary action (bending, detorsion, elongation, movement, push-up, three points). The experts developed a definition for each item and were able to classify the 15 published braces into nine groups. CONCLUSION: The classification is based on the best current expertise (the lowest level of evidence). Experts recognize that this is the first edition and will change with future understanding and research. The broad application of this classification could have value for brace research, education, clinical practice, and growth in this field.
- Klíčová slova
- Brace, Classification, Idiopathic scoliosis,
- MeSH
- konsensus MeSH
- lidé MeSH
- protetické prostředky MeSH
- skolióza * terapie MeSH
- výsledek terapie MeSH
- výztuhy * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
PURPOSE: Separation of C2 growth plates and dens fractures are the most common types of injuries to the axis (C2) in children. Operative treatment of these injuries with the use of direct osteosynthesis requires a profound knowledge of detailed anatomy and dimensions of the axis. The main issue addressed by the study was the age at which the size of the dens is adequate at all levels to accommodate two screws, and the size of the posterior dens angulation angle (PDAA) in a healthy child in individual age periods. METHODS: Dimensions and angles of the dens and C2 in individual age categories in both boys and girls were measured in a series of 203 CT scans of individuals 0-18 years old and on anatomical specimens (42 samples). In addition, 5 histological series of this region from the fetal period were reviewed. RESULTS: Dimensions of the dens gradually increase with age, with a considerable acceleration during growth spurt periods that are different in boys and girls. PDAA is markedly changing with age; in the fetal period, the dens shows a slight anterior angulation which gradually transforms into posterior angulation, as early as between 4 and 6 years of age. The screw insertion angle changes accordingly. CONCLUSION: During growth, there occur changes in PDAA that should be respected in evaluation of transformation of anterior into posterior angulation, as shown by imaging methods. Dens dimensions theoretically allow insertion of two 3.5 mm screws as early as from the age of 1 year.
- Klíčová slova
- Developmental changes, Pediatric C2 anatomy, Posterior dens angulation angle, Screw insertion angle,
- MeSH
- dens axis * diagnostické zobrazování zranění chirurgie MeSH
- dítě MeSH
- fraktury páteře * diagnostické zobrazování chirurgie MeSH
- kojenec MeSH
- kostní šrouby MeSH
- lidé MeSH
- mladiství MeSH
- novorozenec MeSH
- předškolní dítě MeSH
- radiografie MeSH
- vnitřní fixace fraktury MeSH
- Check Tag
- dítě MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- novorozenec MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
PURPOSE: The cement augmentation of a conventional anterior screw fixation in type II odontoid process fractures for elderly patients significantly increased stiffness and load to failure under anterior-posterior load in comparison with non-augmented fixation. The amount and quality of bone cement are usually taken ad hoc in clinical practise. In this study, we wanted to clarify the role of bone cement amount and its quality to the stiffness of odontoid and vertebrae body junction. METHODS: Finite-element method was used to achieve different scenarios of cement augmentation. For all models, an initial stiffness was calculated. Model (1) the intact vertebrae were virtually potted into a polymethylmethacrylate base via the posterior vertebral arches. A V-shaped punch was used for loading the odontoid in an anterior-posterior direction. (2) The odontoid fracture type IIa (Anderson-D'Alonzo classification) was achieved by virtual transverse osteotomy. Anterior screw fixation was virtually performed by putting self-drilling titanium alloy 3.5 mm diameter anterior cannulated lag screw with a 12 mm thread into the inspected vertebrae. A V-shaped punch was used for loading the odontoid in an anterior-posterior direction. The vertebrae body was assumed to be non-cemented and cemented with different volume. RESULTS: The mean cement volume was lowest for body base filling with 0.47 ± 0.03 ml. The standard body filling corresponds to 0.95 ± 0.15 ml. The largest volume corresponds to 1.62 ± 0.12 ml in the presence of cement leakage. The initial stiffness of the intact C2 vertebrae was taken as the reference value. The mean initial stiffness for non-porous cement (E = 3000 MPa) increased linearly (R2 = 0.98). The lowest stiffness (123.3 ± 5.8 N/mm) was measured in the intact C2 vertebrae. However, the highest stiffness (165.2 ± 5.2 N/mm) was measured when cement leakage out of the odontoid peg occurred. The mean initial stiffness of the base-only cemented group was 147.2 ± 8.4 N/mm compared with 157.9 ± 6.6 N/mm for the base and body cemented group. This difference was statistically significant (p < 0.0061). The mean initial stiffness for porous cement (E = 500 MPa) remains constant. Therefore, there is no difference between cemented and non-cemented junction. This difference was not statistically significant (p < 0.18). CONCLUSION: The present study showed that the low porous cement was able to significantly influence the stiffness of the augmented odontoid screw fixation in vitro, although further in vivo clinical studies should be undertaken. Our results suggest that only a small amount of non-porous cement is needed to restore stiffness at least to its pre-fracture level and this can be achieved with the injection of 0.7-1.2 ml of cement. These slides can be retrieved under Electronic Supplementary Material.
- Klíčová slova
- Bone cement, Finite element, Fracture, Odontoid, Spine,
- MeSH
- dens axis * diagnostické zobrazování zranění chirurgie MeSH
- fraktury páteře * diagnostické zobrazování chirurgie MeSH
- kostní cementy terapeutické užití MeSH
- kostní šrouby MeSH
- lidé MeSH
- senioři MeSH
- vnitřní fixace fraktury MeSH
- Check Tag
- lidé MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- kostní cementy MeSH
PURPOSE: Recent research shows an increasing recognition that organisms not traditionally considered infectious in nature contribute to disease processes. Propionibacterium acnes (P. acnes) is a gram-positive, aerotolerant anaerobe prevalent in the sebaceous gland-rich areas of the human skin. A ubiquitous slow-growing organism with the capacity to form biofilm, P. acnes, recognized for its role in acne vulgaris and medical device-related infections, is now also linked to a number of other human diseases. While bacterial culture and molecular techniques are used to investigate the involvement of P. acnes in such diseases, definitive demonstration of P. acnes infection requires a technique (or techniques) sensitive to the presence of biofilms and insensitive to the presence of potential contamination. Fortunately, there are imaging techniques meeting these criteria, in particular, fluorescence in situ hybridization and immunofluorescence coupled with confocal laser scanning microscopy, as well as immunohistochemistry. METHODS: Our literature review considers a range of microscopy-based studies that provides definitive evidence of P. acnes colonization within tissue from a number of human diseases (acne vulgaris, degenerative disc and prostate disease and atherosclerosis), some of which are currently not considered to have an infectious etiology. RESULTS/CONCLUSION: We conclude that P. acnes is an opportunistic pathogen with a likely underestimated role in the development of various human diseases associated with significant morbidity and, in some cases, mortality. As such, these findings offer the potential for new studies aimed at understanding the pathological mechanisms driving the observed disease associations, as well as novel diagnostic strategies and treatment strategies, particularly for degenerative disc disease. These slides can be retrieved under Electronic Supplementary Material.
- Klíčová slova
- Acne vulgaris, Arthroscopy, Atherosclerosis, Biofilm, Cutibacterium acnes, Degenerative disc disease, FISH-CLSM, Propionibacterium acnes, Prostate cancer,
- MeSH
- acne vulgaris diagnostické zobrazování mikrobiologie MeSH
- biofilmy * MeSH
- degenerace meziobratlové ploténky * diagnostické zobrazování mikrobiologie MeSH
- grampozitivní bakteriální infekce * diagnostické zobrazování mikrobiologie MeSH
- lidé MeSH
- mikroskopie * MeSH
- Propionibacterium acnes * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
Unfortunately, the complete conflict of interest statement was missed out in the original publication. The same is given below.
- Publikační typ
- tisková chyba MeSH