Lab Tests Online
Dotaz
Zobrazit nápovědu
Polymeric nano- and microfibers were tested as potential sorbents for the extraction of five neonicotinoids from natural waters. Nanofibrous mats were prepared from polycaprolactone, polyvinylidene fluoride, polystyrene, polyamide 6, polyacrylonitrile, and polyimide, as well as microfibers of polyethylene, a polycaprolactone nano- and microfiber conjugate, and polycaprolactone microfibers combined with polyvinylidene fluoride nanofibers. Polyimide nanofibers were selected as the most suitable sorbent for these analytes and the matrix. A Lab-In-Syringe system enabled automated preconcentration via online SPE of large sample volumes at low pressure with analyte separation by HPLC. Several mat layers were housed in a solvent filter holder integrated into the injection loop of an HPLC system. After loading 2 mL sample on the sorbent, the mobile phase eluted the retained analytes onto the chromatographic column. Extraction efficiencies of 68.8-83.4% were achieved. Large preconcentration factors ranging from 70 to 82 allowed reaching LOD and LOQ values of 0.4 to 1.7 and 1.2 to 5.5 µg·L-1, respectively. Analyte recoveries from spiked river waters ranged from 53.8% to 113.3% at the 5 µg·L-1 level and from 62.8% to 119.8% at the 20 µg·L-1 level. The developed methodology proved suitable for the determination of thiamethoxam, clothianidin, imidacloprid, and thiacloprid, whereas matrix peak overlapping inhibited quantification of acetamiprid.
- Klíčová slova
- Lab-In-Syringe, membrane preconcentration, nanofibers, neonicotinoids, online SPE,
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: Chronic kidney disease (CKD) is a global health issue, ranking as the third leading cause of death worldwide. CKD diagnosis and management depend on clinical laboratory tests, necessitating consistency for precise patient care. Global harmonization of CKD testing through clinical practice guidelines (CPGs) is recommended. Prior to CPG development, assessing the current CKD testing landscape is crucial. In 2022, the European Federation of Laboratory Medicine (EFLM) conducted an online survey among European laboratories associated with EFLM, evaluating CKD testing practices, including new glomerular filtration rate (GFR) estimation methods. This report summarizes the 2022 survey findings and offers recommendations for improving CKD test standardization. METHODS: An online survey was conducted in November 2022 using a questionnaire hosted on LimeSurvey sent to European laboratories affiliated with the EFLM. The survey results were recorded in Excel files and analysed. RESULTS: The results highlight significant discrepancies among countries in unit expression, methods, cystatin C use, and GFR calculation equations. Additionally, limited attention to pediatric renal biology specifics, varied proteinuria and albuminuria result expressions, and limited awareness of GFR measurement methods through iohexol clearance are noted. CONCLUSIONS: In an effort to enhance the standardization of crucial biomarkers utilized in nephrology for evaluating renal function and diagnosing kidney injuries, the EFLM Task Group on CKD suggests nine practical recommendations tailored for European laboratories. The group is confident that implementing these measures will minimize result expression discrepancies, ultimately leading to enhanced patient care.
- Klíčová slova
- creatinine, cystatin C, equations, glomerular filtration rate, recommendations, survey,
- MeSH
- biologické markery MeSH
- chronická renální insuficience * diagnóza MeSH
- dítě MeSH
- hodnoty glomerulární filtrace MeSH
- kreatinin metabolismus MeSH
- laboratoře * MeSH
- lidé MeSH
- průzkumy a dotazníky MeSH
- vyšetření funkce ledvin metody MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- biologické markery MeSH
- kreatinin MeSH