pulsatility index Dotaz Zobrazit nápovědu
AIMS: Recipients of left ventricular assist devices (LVAD) are exposed to increased risk of adverse clinical events. One of the potential contributing factors is non-pulsatile flow generated by LVAD. We evaluated the association of flow patterns in carotid arteries and of increased arterial stiffness with death and cerebrovascular events in LVAD recipients. METHODS AND RESULTS: We analysed data from 83 patients [mean age 54 ± 15 years; 12 women; HeartMate II (HMII), n = 34; HeartMate 3 (HM3), n = 49]. Pulsatile and resistive indexes, atherosclerotic changes in carotid arteries (measured by duplex ultrasound), and arterial stiffness [measured by Endo-PAT 2000 as the augmentation index standardized for heart rate (AI@75)] were evaluated 3 and 6 months after LVAD implantation. Sixteen patients died during follow-up (27.3 months; interquartile range 15.7-44.3). After adjusting for the main variables examined, the pulsatility index measured at 3 months was positively associated with increased hazard ratios (HR) for death and cerebrovascular events [HR 9.8, 95% confidence interval (CI) 1.62-59.42], with HR increasing after adding AI@75 to the model (HR 18.8, 95% CI 2.44-145.50). In HM3 recipients, HR was significantly lower than in HMII recipients (HR 0.31, 95% CI 0.11-0.91), but the significance disappeared after adding AI@75 to the model (HR 0.33, 95% CI 0.09-1.18). CONCLUSIONS: The risk of death and cerebrovascular events in LVAD recipients is associated with increased pulsatility index in carotid arteries and potentiated by increased arterial stiffness. The same risk is attenuated by HM3 LVAD implantation, but this effect is weakened by increased arterial stiffness.
- Klíčová slova
- Clinical events, Mechanical circulatory support, Pulsatility index,
- MeSH
- ateroskleróza * MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- podpůrné srdeční systémy * MeSH
- senioři MeSH
- srdeční selhání * MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
INTRODUCTION: Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the 'cuff pulsatility index'. PURPOSE: The purpose of this study was to evaluate the relationship between the cuff pulsatility index and invasively determined arterial pulsatility in patients with a left ventricular assist device. METHODS: Twenty-three patients with a left ventricular assist device with end-stage heart failure (six females: age = 65 ± 9 years; body mass index = 30.5 ± 3.7 kg m-2) were recruited for this study. Suprasystolic occlusions were performed on the upper arm of the patient's dominant side, from which the cuff pressure waveform was obtained. Arterial blood pressure was obtained from the radial artery on the contralateral arm. Measurements were obtained in triplicate. The relationship between the cuff pressure and arterial blood pressure waveforms was assessed in the frequency-domain using coherence analysis. A mixed-effects approach was used to assess the relationship between cuff pulsatility index and invasively determined arterial pulsatility (i.e. pulse pressure). RESULTS: The cuff pressure and arterial blood pressure waveforms demonstrated a high coherence up to the fifth harmonic of the cardiac frequency (heart rate). The cuff pulsatility index accurately tracked changes in arterial pulse pressure within a given patient across repeated measurements. CONCLUSIONS: The cuff pulsatility index shows promise as a non-invasive index for monitoring residual arterial pulsatility in patients with a left ventricular assist device across time.
- Klíčová slova
- Left ventricular assist device, non-invasive, pulsatility index,
- MeSH
- arterie patofyziologie MeSH
- asistovaná cirkulace přístrojové vybavení metody MeSH
- diagnostické techniky kardiovaskulární MeSH
- krevní tlak fyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- podpůrné srdeční systémy * MeSH
- pulz metody MeSH
- pulzatilní průtok fyziologie MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- srdeční selhání * patofyziologie terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
UNLABELLED: To specify diagnostic importance of fetoplacental flow parameters PI, RI during pregnancy complicated by ultrasonografically detected intrauterine growth retardation-IUGR. SETTING: Dpt. of Obstetric and Gynaecology, Safarik's University and University Hospital L. Pasteur, Kosice, Slovak Republic, Obst/Gynae Dpt., Victoria Hospital, Mahé, Seychelles Republic, Indian Ocean. SUBJECT AND METHOD: The autors measured fetal circulation on the level of descending aortal bifurcation. The results were compared in the Group-A of 112 pregnancies complicated by mild, moderate and several praeeclampsia, eclampsia with detected IUGR, and comparative Group-B of 106 pregnancies. INTERVENTION: The ACUSONIC 8, ALOKA 680 SSD using transabdominal 3.5 MHz probe with color doppler facility. The parameters were measured in weekly intervals according the clinical protocol for management of high risk pregnancies. SUBJECTS: There was opened a prospective comparative study of 112 risk pregnancies (Group-A) and a comparative Group-B of 106 pregnancies with normal growth of fetuses. Group-A was devided according classification of praeeclampsia to Subgroup-A1, mild praeeclampsia, Subgroup-A2, moderate praeeclampsia, Subgroup-A3, severe praeclampsia and Subgroup-A4, eclampsia. Parameters of vascular resistance in descending aorta were calculated from 28th week of gestation to termination of pregnancy and compared average values in corresponding stage in the Group-A and the comparative Group-B. Number of IUGR fetuses or restricted with the growth were calculated in Subgroups-A. RESULTS: Descending aorta presents significantly higher average values of PI, RI during pregnancy from 28th week of gestation in Group-A. There is no evidence of diastolic decrease after 34th week of gestation in Group-A. In Group-A 52.6% fetuses were ultrasonograficaly IUGR detected or restricted. In Subgroup-A1 of mild praeeclampsia were 20.5% of the IUGR fetuses. Subgroup-A2 of moderate praeeclampsia showed 51.3% and Subgroup-A3 severe praeeclampsia 87.8% of the IUGR fetuses of restricted. Three cases of eclampsia were restricted for growth. MAIN OUTCOME: Functional assessment of the descending aorta flow is the most reliable method for differentiation of praeclamptic and eclamptic pregnancies with suspected fetal starvation and intrauterine growth retardation.
- MeSH
- aorta diagnostické zobrazování MeSH
- cévní rezistence * MeSH
- lidé MeSH
- preeklampsie komplikace MeSH
- pulzatilní průtok * MeSH
- růstová retardace plodu diagnóza etiologie patofyziologie MeSH
- rychlost toku krve MeSH
- těhotenství MeSH
- ultrasonografie dopplerovská barevná * MeSH
- ultrasonografie prenatální MeSH
- Check Tag
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Peripheral arterial disease (PAD) is common in patients with acute cerebral ischemia. Indexes of resistance derived from the systolic and diastolic velocities are routinely used in diagnostic transcranial Doppler (TCD) to detect intracranial arterial disease. We sought to explore whether these indexes can predict the presence of PAD in acute cerebral ischemia. METHODS: We prospectively evaluated consecutive patients with acute cerebral ischemia. On TCD, peak-systolic and end-diastolic velocities in both middle cerebral and basilar arteries were manually measured to calculate pulsatility index (PI) and resistance index (RI). Increased resistance was defined as PI equal to 1.2 or more and RI equal to .75 or more. Ankle-brachial index (ABI) measurements were performed and an ABI equal to .9 or more was considered predictive of definite PAD. RESULTS: We included 95 patients (45 male, 50 female) aged 66 ± 9 years with a median National Institutes Health Stroke Scale score of 3 (interquartile range, 8) points. The ABI was abnormal and consistent with definite PAD in 24 of 95 (25.3%; 95% confidence interval [CI], 16.4-34.2) patients. Increased PI did not differ among patients with and without PAD (20.8% vs. 28.2%, P = .60). Only 1 patient with PAD had increased RI as opposed to 4 patients without PAD (4.2% vs. 5.6%, P = 1.0). Increased PI was not found to be an independent predictor of PAD (odds ratio [OR], .68; 95% CI, .22-2.12; P = .51). Increases in both PI and RI independently predicted arterial hypertension (OR, 1.62; 95% CI, 1.19-2.21; P = .002 and OR, 3.20; 95% CI, 1.51-6.77; P = .002, respectively). CONCLUSIONS: Our findings indicate that PAD cannot be inferred from intracranial flow parameters predictive of arterial disease and risk factors such as hypertension among patients with acute cerebral ischemia.
- Klíčová slova
- Stroke, intracranial disease, peripheral arterial disease, transcranial Doppler,
- MeSH
- cévní mozková příhoda komplikace diagnostické zobrazování MeSH
- fibrilace síní komplikace diagnostické zobrazování MeSH
- ischemie mozku komplikace diagnostické zobrazování MeSH
- lidé středního věku MeSH
- lidé MeSH
- mozkový krevní oběh * MeSH
- onemocnění periferních arterií komplikace diagnostické zobrazování MeSH
- prospektivní studie MeSH
- rizikové faktory MeSH
- senioři MeSH
- tlakový index kotník-paže MeSH
- tranzitorní ischemická ataka komplikace diagnostické zobrazování MeSH
- ultrasonografie dopplerovská transkraniální MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Ankle brachial index (ABI) has been increasingly used in general practice to identify individuals with low ABI at high cardiovascular risk. However, there has been no consensus on the clinical significance of high ABI. The aim of our study was to compare aortic stiffness as a marker of cardiovascular risk in individuals with low (<1.0), normal (1.0-1.4), and high ABI (>1.4). METHODS: A total of 911 individuals from the Czech post-MONICA study (a randomly selected 1% representative population sample, aged 54 ± 13.5 years, 47% of men) were examined. ABI was measured using a handheld Doppler and aortic pulse wave velocity (aPWV) using the Sphygmocor device. RESULTS: Of the 911 individuals, 28 (3.1%) had low ABI and 23 (2.5%) high ABI. There was a U-shaped association between aPWV and ABI. aPWV was significantly higher in individuals with low and high ABI compared with the normal ABI group (11.1 ± 2.8, 8.3 ± 2.3, p < 0.001; 10.8 ± 2.5, 8.3 ± 2.3 m/s, p < 0.001, respectively). In a model adjusted for age, sex, systolic, diastolic, mean blood pressure and examiner, aPWV remained increased in both extreme ABI groups compared with the normal ABI group. In logistic regression analysis, aPWV together with glucose level, male sex, and a history of deep venous thrombosis were independent predictors of high ABI, while cholesterol was not. CONCLUSION: This is the first study showing increased aortic stiffness in individuals with high ABI, presumably responsible for increased left ventricular mass described previously in this group. These findings suggest increased cardiovascular risk of high ABI individuals.
- MeSH
- analýza rozptylu MeSH
- aorta diagnostické zobrazování patofyziologie MeSH
- dospělí MeSH
- hodnocení rizik MeSH
- kardiovaskulární nemoci diagnóza diagnostické zobrazování etiologie patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- logistické modely MeSH
- poddajnost MeSH
- prediktivní hodnota testů MeSH
- pulzatilní průtok * MeSH
- rizikové faktory MeSH
- senioři MeSH
- tlakový index kotník-paže * MeSH
- ultrasonografie dopplerovská MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH
The differentiation between chronic pulmonary thromboembolic hypertension (CTEPH) and pulmonary arterial hypertension (PAH) remains a clinical challenge. The aim of our study was to evaluate the usefulness of both echocardiographically and invasively derived pulmonary artery pulsatility indexes in the etiologic differentiation of patients with CTEPH and PAH. We retrospectively analyzed the results of echocardiographic and invasive hemodynamic examinations in 125 patients with either CTEPH (n = 62) or PAH (n = 63). Invasive data were obtained in 52 patients with CTEPH and 43 PAH patients. Using echocardiography, pulmonary artery systolic (PASP), diastolic (PADP) and mean (PAMP) pressures were estimated from velocities of tricuspid regurgitation and pulmonary regurgitation, respectively. Pulse pressure (PP) was calculated as the difference between PASP and PADP. To obtain pulmonary artery pulsatility indexes, we normalized PP by PASP (PP/PASP), by PAMP (PP/PAMP) and by PADP (PP/PADP). Pulsatility indexes assessed by echocardiography did not differ between CTEPH and PAH patients except for PP/PAMP [PP/PAMP (1.82 ± 0.33 vs. 1.40 ± 0.3, p < 0.001)]. Invasively derived pulsatility indexes were significantly higher in subjects with CTEPH (0.60 ± 0.08 vs. 0.53 ± 0.09 for PP/PASP; 0.98 ± 0.21 vs. 0.81 ± 0.21 for PP/PAMP; 1.58 ± 0.52 vs. 1.21 ± 0.41 for PP/PADP; all p < 0.001). The areas under the receiver-operating characteristic curves analysis showed that no cutoff value allowed discriminating between CTEPH and PAH by using echocardiographically or invasively derived pulsatility indices. Invasively derived pulmonary artery pulsatility indexes as well as echocardiographically determined PP/PAMP indexes are higher in CTEPH compared to PAH. However, due to the important overlap no optimal threshold values of these parameters can be given to allow satisfactory discrimination of the two diseases in clinical practice.
- MeSH
- arteria pulmonalis diagnostické zobrazování patofyziologie MeSH
- chronická nemoc MeSH
- diferenciální diagnóza MeSH
- dopplerovská echokardiografie * MeSH
- dospělí MeSH
- familiární plicní arteriální hypertenze MeSH
- krevní tlak MeSH
- lidé středního věku MeSH
- lidé MeSH
- lineární modely MeSH
- plicní embolie diagnóza diagnostické zobrazování patofyziologie MeSH
- plicní hypertenze diagnóza diagnostické zobrazování patofyziologie MeSH
- plicní oběh * MeSH
- prediktivní hodnota testů MeSH
- pulzatilní průtok * MeSH
- retrospektivní studie MeSH
- ROC křivka MeSH
- senioři MeSH
- srdeční katetrizace * MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
- Geografické názvy
- Česká republika MeSH
OBJECTIVE: Aortic stiffness is increased in lacunar stroke. The precise mechanism linking aortic stiffness to symptomatic lacunar stroke is not well understood. The aim of this study was to compare the effects of aortic stiffness, carotid stiffness, central blood pressure, and cerebrovascular resistance on carotid flow pulsatility according to stroke subtype. METHODS: Two hundred and one consecutive patients were examined 13 months after hospitalization for their first-ever ischemic stroke. The stroke subtype was classified using the Causative Classification of Stroke System. Carotid-femoral pulse wave velocity (PWV) was used as a measure of aortic stiffness. Common carotid flow pulsatility was expressed as resistive index. Central blood pressure was measured using applanation tonometry. RESULTS: Complete data were available for 174 patients (mean age… 67 ± 10 years, 64% men). In patients with lacunar stroke, aortic PWV was higher (13.11 ± 2.74 m/s) than in individuals with large artery atherosclerosis (9.98 ± 1.87 m/s, P <0.001), cardioembolic (11.31 ± 3.18 m/s, P = 0.04) or cryptogenic stroke (11.13 ± 3.2 m/s, P = 0.01). Similarly, central SBP and resistive index were higher in patients with lacunar stroke (145 ± 23 mmHg and 0.80 ± 0.04, respectively) than those with large artery atherosclerosis (128 ± 18 mmHg, P <0.01 and 0.74 ± 0.07, P <0.01, respectively) or cryptogenic stroke (132 ± 18 mmHg, P <0.01 and 0.76 ± 0.07, P <0.05, respectively). In multivariate analysis, aortic stiffness and central pulse pressure were the main determinants of resistive index independent of stroke subtype. CONCLUSION: Our results suggest that aortic stiffening, by reducing the buffering function of the aorta and thereby increasing the transmission of pressure and flow pulsatility into the cerebral arterioles, may contribute to the pathogenesis of lacunar stroke.
- MeSH
- analýza pulzové vlny MeSH
- arteriae carotides patofyziologie MeSH
- cévní mozková příhoda patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- přežívající * MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- tuhost cévní stěny * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: Implantation of left-ventricular assist systems (LVASs) has become the standard of care for advanced heart failure (HF). The absence of pulsatility in previous devices contributes to vascular and endothelial dysfunction related to atherosclerotic or vascular complications. We hypothesized that the artificial pulsatility provided by the HeartMate 3 (HM3) (Abbott, Chicago, IL) LVAS would exert a favourable effect on the vasculature. METHODS: In 32 patients implanted with HM3 (5 female patients, mean age 55 ± 13.6 years), the reactive hyperemia index (RHI) and peripheral augmentation index (AI), markers of endothelial function and arterial stiffness, were measured with an EndoPAT2000 before and in the third and sixth month after implantation. RHI and AI data from 30 HeartMate II (HM II) (Abbott) recipients in the third and sixth month after implantation, from 15 patients with advanced HF without LVASs and from 13 healthy volunteers were also analyzed. RESULTS: In HM3 recipients, the mean RHI significantly decreased at 3 and 6 months after implantation. The RHI was substantially lower at baseline than that of healthy or the HF reference group. Increasing AI values, indicating worsening arterial stiffness, were also observed. Similar trends were observed in HM II recipients between the third and sixth months but with higher absolute values of RHI and AI. CONCLUSIONS: We detected impaired vascular function in HM3 patients and provided additional evidence on the negative effect of low pulsatility on vascular function after LVAS implantation. The results suggest that the artificial pulsatility of the HM3 does not avert the progression of endothelial dysfunction.
- MeSH
- arterie patofyziologie MeSH
- časové faktory MeSH
- cévní endotel patofyziologie MeSH
- cévní rezistence fyziologie MeSH
- funkce levé komory srdeční fyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- podpůrné srdeční systémy * MeSH
- prospektivní studie MeSH
- srdeční komory patofyziologie MeSH
- srdeční selhání patofyziologie terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
While determinants of aortic pulse wave velocity (aPWV) are well known, much less is known about factors affecting lower-extremity pulse wave velocity (lePWV). Unlike aPWV, increased lePWV does not predict cardiovascular risk, but limits lower-extremity blood flow and is associated with increased left ventricular mass. The aim of this study was to compare the effect of cardiovascular risk factors on aPWV and lePWV. A total of 911 individuals from the Czech post-MONICA study (a randomly selected 1% representative population sample, mean age 54±13.5 years, 47% men) were examined. Pulse wave velocity was measured using the SphygmoCor device. Aging had a large effect on aPWV, but only a small effect on lePWV. After adjustment for covariates, we observed that hypertension, diabetes, chronic kidney disease and dyslipidemia were positively and significantly associated with aPWV. However, only hypertension had a significant effect on lePWV. Increased ankle systolic blood pressure was associated with increased aPWV independently of brachial blood pressure. Ankle systolic blood pressure was more closely related to aPWV than lePWV. Subjects with an ankle-brachial index <1.0 had higher aPWV and lower lePWV compared with individuals with a normal ankle-brachial index. Lower-extremity arterial stiffness is affected by age and cardiovascular risk factors to a lesser extent than aortic stiffness. Increased ankle systolic blood pressure is linked not only to increased lower-extremity arterial stiffness, but also increased aortic stiffness. In subjects with a low ankle-brachial index, lower-extremity arterial stiffness is spuriously decreased.
- MeSH
- analýza pulzové vlny MeSH
- aorta patofyziologie MeSH
- cévní rezistence fyziologie MeSH
- dospělí MeSH
- kardiovaskulární nemoci diagnóza patofyziologie MeSH
- krevní tlak fyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- pulzatilní průtok fyziologie MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- sexuální faktory MeSH
- tlakový index kotník-paže MeSH
- tuhost cévní stěny fyziologie MeSH
- věkové faktory MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The aim of this paper is to prove the possible reproducibility of measurement with a new developed device for artery elasticity monitoring and determining the standard of major pulse wave parameters. As a measurement sensor, a conic probe with thin convex membrane was used. This technique allows setting an arbitrary pressure to a measured surface artery. We measured pulse waves on the radial arteries of 108 individuals. We expected similar features in arterial wall elasticity. We concentrated primarily on the amount of subcutaneous fat. For the measured waves we evaluated five following pulse wave parameters: relative crest time, elasticity index, dicrotic wave attenuation, dicrotic wave time and interwave distance. There were no significant differences in measured pulse wave parameters among the tested groups of subjects.
- MeSH
- arteria radialis * fyziologie MeSH
- diagnostické techniky kardiovaskulární * MeSH
- index tělesné hmotnosti MeSH
- lidé MeSH
- měniče tlakové MeSH
- počítačové zpracování signálu MeSH
- pružnost MeSH
- pulz * MeSH
- pulzatilní průtok * MeSH
- reprodukovatelnost výsledků MeSH
- rychlost toku krve MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- validační studie MeSH