• Je něco špatně v tomto záznamu ?

Comparison of the anterior Bolton ratio among different malocclusal groups : Ortodoncie. Sborník abstrakt. Poster

Božena Badelek-Mirek, Grazyna Smiech-Slomkowska

. 2002 ; Roč. 11 (3A Sborník abstrakt) : s. 15.
. 2002 ; Roč. 11 (3A Sborník abstrakt) : s. 15.

Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc03005334

The purpose of thsi study was to determine whether there is a prevalent tendency for intermaxillary tooth size discrepancies among different malocclusion groups. The tooth size measurements were performed clinically. Six anterior maxillary and mandibular teeth were measured by electronic device to determined the Bolton anterior ratio. The total of 18612-year-old children have been selected randomly from the city of Lodz and the area. The value of the anterior ratio has been compared in the class I,II and III malocclusion cases. The ideal occlusal situation has been also taken into consideration. The mean value of the Bolton anterior ratio in the cases tested were: 1. Ideal occlusion 81,39, 2. Class 1 malocclusion 81,39, 3. Class II malocclusion 81,28, 4. Class 111 malocclusion 78,27 , P=0,215 Our data reveal no significant difference between the values of the Bolton anterior ratio, compared to 4 different occlusal situations.

000      
00000naa a2200000 a 4500
001      
bmc03005334
003      
CZ-PrNML
005      
20180622092059.0
008      
030300s2002 xr u eng||
009      
PC
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Badelek-Mirek, Božena $4 aut
245    10
$a Comparison of the anterior Bolton ratio among different malocclusal groups : $b Ortodoncie. Sborník abstrakt. Poster. / $c Božena Badelek-Mirek, Grazyna Smiech-Slomkowska
314    __
$a Department of Orthodontics, Institute of Dentistry, Medical University, Lodz, PL
520    9_
$a The purpose of thsi study was to determine whether there is a prevalent tendency for intermaxillary tooth size discrepancies among different malocclusion groups. The tooth size measurements were performed clinically. Six anterior maxillary and mandibular teeth were measured by electronic device to determined the Bolton anterior ratio. The total of 18612-year-old children have been selected randomly from the city of Lodz and the area. The value of the anterior ratio has been compared in the class I,II and III malocclusion cases. The ideal occlusal situation has been also taken into consideration. The mean value of the Bolton anterior ratio in the cases tested were: 1. Ideal occlusion 81,39, 2. Class 1 malocclusion 81,39, 3. Class II malocclusion 81,28, 4. Class 111 malocclusion 78,27 , P=0,215 Our data reveal no significant difference between the values of the Bolton anterior ratio, compared to 4 different occlusal situations.
650    _2
$a malokluze $x KLASIFIKACE $7 D008310
650    _2
$a lidé $7 D006801
650    _2
$a dítě $7 D002648
700    1_
$a Smiech-Slomkowska, Grazyna $4 aut
773    0_
$w MED00011058 $t Ortodoncie $g Roč. 11, č. 3A Sborník abstrakt (2002), s. 15 $x 1210-4272
773    0_
$t Sborník abstrakt $x 1210-4272 $g Roč. 11, č. 3A Sborník abstrakt (2002), s. 15 $w MED00114586
910    __
$a ABA008 $b A 4037 $c 823 $y 0 $z 0
990    __
$a 20030415 $b ABA008
991    __
$a 20180622092325 $b ABA008
BAS    __
$a 6
BMC    __
$a 2002 $b Roč. 11 $c 3A Sborník abstrakt $d s. 15 $i 1210-4272 $m Ortodoncie $x MED00011058
BMC    __
$a 2002 $b Roč. 11 $c 3A Sborník abstrakt $d s. 15 $i 1210-4272 $m Sborník abstrakt $x MED00114586
LZP    __
$b přidání abstraktu

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...