Something wrong with this record ?
Influence of different luting agents on the marginal discrepancy of procera® AllCeram alumina crown copings – an experimental study
Shriharsha Pilathadka, Radovan Slezák, Dagmar Vahalová, Marina George Kudiyirickal, Sujith Sukumar
Language English Country Czech Republic
Document type Evaluation Study, Comparative Study
Digital library NLK
Full text - Article
Issue
Volume
Source
Source
NLK
Directory of Open Access Journals
from 1997
Free Medical Journals
from 1997
Open Access Digital Library
from 1997-01-01
ROAD: Directory of Open Access Scholarly Resources
from 1997
- MeSH
- Cementation methods MeSH
- Resin Cements MeSH
- Glass Ionomer Cements therapeutic use MeSH
- Zinc Phosphate Cement therapeutic use MeSH
- Dental Cements classification therapeutic use MeSH
- Dental Materials classification therapeutic use MeSH
- Publication type
- Evaluation Study MeSH
- Comparative Study MeSH
Two maxillary first molars and two central incisor typhodont teeth were prepared with 0.8 mm chamfer, 2.0 mm occlusal reduction, and 6 degree taper. The prepared teeth were duplicated 9 times to obtain 36 die stone models and divided into three groups (n = 12). Luting agents tested were zinc phosphate, glass ionomer and resin cement. Procera®AllCeram 0.6 mm coping was fixed with a calibrated finger force of 50 N. The absolute marginal discrepancy was measured using the scanning electron microscope on four axial walls with 4 measurements on each wall to obtain a total of 16 readings for one tooth. Mann Whitney U test was applied to find significant differences between luting cements and Kruskal Wallis tests among groups. Results The absolute marginal discrepancies of cements were in reducing order zinc phosphate (AZ) 53 µm; resin (AR) 44.5 µm, glass ionomer (AG) 29 µm. There was a significant difference among luting cements AG V/s AZ (p = 0.001) and AR V/s AG (p = 0.003), except AR V/s AZ (p = 0.213). All axial surfaces except mesial showed a significant difference. Conclusion The study concluded that different luting media have a definite effect over the final fit of AllCeram coping. Absolute marginal discrepancy was within the accepted level of 100 µm. Distal axial surface demonstrated a wider gap among all the luting agents
References provided by Crossref.org
Lit.: 32
- 000
- 03379naa 2200433 a 4500
- 001
- bmc07507715
- 003
- CZ-PrNML
- 005
- 20111210123007.0
- 008
- 080812s2008 xr e eng||
- 009
- AR
- 024 7_
- $a 10.14712/18059694.2017.2 $2 doi
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Pilathadka, Shriharsha. $7 _BN005210
- 245 10
- $a Influence of different luting agents on the marginal discrepancy of procera® AllCeram alumina crown copings – an experimental study / $c Shriharsha Pilathadka, Radovan Slezák, Dagmar Vahalová, Marina George Kudiyirickal, Sujith Sukumar
- 314 __
- $a Charles University in Prague, Department of Dentistry, Faculty of Medicine and University Hospital, Hradec Králové
- 504 __
- $a Lit.: 32
- 520 9_
- $a Two maxillary first molars and two central incisor typhodont teeth were prepared with 0.8 mm chamfer, 2.0 mm occlusal reduction, and 6 degree taper. The prepared teeth were duplicated 9 times to obtain 36 die stone models and divided into three groups (n = 12). Luting agents tested were zinc phosphate, glass ionomer and resin cement. Procera®AllCeram 0.6 mm coping was fixed with a calibrated finger force of 50 N. The absolute marginal discrepancy was measured using the scanning electron microscope on four axial walls with 4 measurements on each wall to obtain a total of 16 readings for one tooth. Mann Whitney U test was applied to find significant differences between luting cements and Kruskal Wallis tests among groups. Results The absolute marginal discrepancies of cements were in reducing order zinc phosphate (AZ) 53 µm; resin (AR) 44.5 µm, glass ionomer (AG) 29 µm. There was a significant difference among luting cements AG V/s AZ (p = 0.001) and AR V/s AG (p = 0.003), except AR V/s AZ (p = 0.213). All axial surfaces except mesial showed a significant difference. Conclusion The study concluded that different luting media have a definite effect over the final fit of AllCeram coping. Absolute marginal discrepancy was within the accepted level of 100 µm. Distal axial surface demonstrated a wider gap among all the luting agents
- 650 _2
- $a zubní cementy $x klasifikace $x terapeutické užití $7 D003738
- 650 _2
- $a zubní materiály $x klasifikace $x terapeutické užití $7 D003764
- 650 _2
- $a cementování $x metody $7 D002484
- 650 _2
- $a zinkfosfátový cement $x terapeutické užití $7 D015036
- 650 _2
- $a pryskyřičné cementy $7 D019279
- 650 _2
- $a skloionomerní cementy $x terapeutické užití $7 D005899
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a srovnávací studie $7 D003160
- 700 1_
- $a Slezák, Radovan, $d 1958- $7 jn20000402232
- 700 1_
- $a Vahalová, Dagmar $7 xx0019422
- 700 1_
- $a Kudiyirickal, Marina George. $7 _BN005211
- 700 1_
- $a Sukumar, Sujith $7 xx0095324
- 773 0_
- $w MED00010947 $t Acta medica (Hradec Králové) $g Roč. 51, č. 1 (2008), s. 13-18 $x 1211-4286
- 856 41
- $u https://actamedica.lfhk.cuni.cz/media/pdf/am_2008051010013.pdf $y plný text volně přístupný
- 910 __
- $y 1 $a ABA008 $b A 3077 $c 1072
- 990 __
- $a 20080812143712 $b ABA008
- 991 __
- $a 20080919090239 $b ABA008
- 999 __
- $a ok $b bmc $g 623321 $s 475754
- BAS __
- $a 3
- BMC __
- $a 2008 $b 51 $c 1 $d 13-18 $i 1211-4286 $m Acta Medica $x MED00010947
- LZP __
- $a 2008-14/mkaš