Analysis of the influence of interdetector volume on local calibration in size exclusion chromatography with dual multiangle-light-scattering/concentration detection

Netopilík M.

. 2006 ; 1113 (1-2) : 162-166.

Jazyk angličtina Země Nizozemsko

Perzistentní odkaz   https://www.medvik.cz/link/bmc07522877

A comparison of the s- and w-detections of molecular weight, a necessary condition for precise determination of interdetector volume in size exclusion chromatography of polymers with the dual light scattering--concentration detection, is examined. From the theoretical analysis for a polymer with the log-normal molecular weight distribution it follows that the error in determination of the local calibration, i.e., of a logarithmic dependence of molecular weight on elution volume obtained by the s-detection, from the known dependence of radius of gyration on elution volume and of molecular weight on the radius of gyration, remains linear and is slightly shifted with respect to that obtained by the w-detection (dual detection giving the weight-average molecular weight) towards higher molecular weights, the difference being below the experimental error. It also follows that the error in the slope of local calibration found by the w-detection is given by the ratio of the error in interdetector volume and the variance of the elution curve. This is demonstrated on several polymer samples with symmetric elution curves of polymer samples differing in polydispersity indices. The range of this rule depends on the broadness and symmetry of elution curves. The precision of the interdetector volume determination depends therefore strongly on the Mw/Mn ratio of the sample.

000      
00000naa 2200000 a 4500
001      
bmc07522877
003      
CZ-PrNML
005      
20111210134554.0
008      
090511s2006 ne e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Netopilík, Miloš $7 xx0115561
245    10
$a Analysis of the influence of interdetector volume on local calibration in size exclusion chromatography with dual multiangle-light-scattering/concentration detection / $c Netopilík M.
314    __
$a Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, 162 06 Prague 6, Czech Republic. netopil@imc.cas.cz
520    9_
$a A comparison of the s- and w-detections of molecular weight, a necessary condition for precise determination of interdetector volume in size exclusion chromatography of polymers with the dual light scattering--concentration detection, is examined. From the theoretical analysis for a polymer with the log-normal molecular weight distribution it follows that the error in determination of the local calibration, i.e., of a logarithmic dependence of molecular weight on elution volume obtained by the s-detection, from the known dependence of radius of gyration on elution volume and of molecular weight on the radius of gyration, remains linear and is slightly shifted with respect to that obtained by the w-detection (dual detection giving the weight-average molecular weight) towards higher molecular weights, the difference being below the experimental error. It also follows that the error in the slope of local calibration found by the w-detection is given by the ratio of the error in interdetector volume and the variance of the elution curve. This is demonstrated on several polymer samples with symmetric elution curves of polymer samples differing in polydispersity indices. The range of this rule depends on the broadness and symmetry of elution curves. The precision of the interdetector volume determination depends therefore strongly on the Mw/Mn ratio of the sample.
650    _2
$a financování organizované $7 D005381
650    _2
$a kalibrace $7 D002138
650    _2
$a gelová chromatografie $x metody $7 D002850
650    _2
$a světlo $7 D008027
650    _2
$a molekulová hmotnost $7 D008970
650    _2
$a radiační rozptyl $7 D012542
773    0_
$w MED00002736 $t Journal of chromatography $g Roč. 1113, č. 1-2 (2006), s. 162-166 $x 0021-9673
910    __
$a ABA008 $b x $y 9
990    __
$a 20090506084234 $b ABA008
991    __
$a 20090511135328 $b ABA008
999    __
$a ok $b bmc $g 650967 $s 504134
BAS    __
$a 3
BMC    __
$a 2006 $b 1113 $c 1-2 $d 162-166 $i 0021-9673 $m Journal of chromatography $x MED00002736
LZP    __
$a 2009-B2/vtme

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...