Standardisation of 54Mn and 65Zn using a software coincidence counting system
Havelka M, Auerbach P, Sochorová J.
Jazyk angličtina Země Velká Británie
Typ dokumentu hodnotící studie
- MeSH
- algoritmy MeSH
- dávka záření MeSH
- mangan analýza normy MeSH
- radioizotopy zinku analýza normy MeSH
- radionuklidy analýza normy MeSH
- referenční hodnoty MeSH
- referenční standardy MeSH
- reprodukovatelnost výsledků MeSH
- scintilace - počítání metody normy MeSH
- senzitivita a specificita MeSH
- směrnice jako téma MeSH
- software MeSH
- spektrometrie gama metody normy MeSH
- Publikační typ
- hodnotící studie MeSH
- Geografické názvy
- Česká republika MeSH
The activities of 54Mn and 65Zn have been determined by 4pi(PC)-gamma coincidence counting, with efficiency variation performed by the conventional method of altering the self-absorption in the sources as well as by the computer discrimination method. The standardisation of 65Zn presents some complications requiring optimisation of the gamma-ray energy window settings to achieve a linear efficiency-extrapolation curve. Determination of these optimal settings by the conventional coincidence method is a tedious task. These difficulties have been reduced by the utilisation of a software coincidence counting system that records time and amplitude information of individual pulses from coincidence measurements, where the coincidence parameters are set after the data collection process has completed, facilitating multiple data evaluations on a single data set. The optimal gamma-ray energy window settings for the 65Zn standardisation were derived from the results of the 54Mn standardisation, as well as from studies of the 65Zn data itself. The setting of the PC channel thresholds for K and both (K+L) electrons is also discussed. The results are compared with those attained using conventional coincidence counting.
Czech Metrology Institute Inspectorate for Ionizing Radiation Radiová 1 102 00 Prague Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07523569
- 003
- CZ-PrNML
- 005
- 20111210135958.0
- 008
- 090520s2006 xxk e eng||
- 009
- AR
- 024 __
- $a 10.1016/j.apradiso.2006.02.024 $2 doi
- 035 __
- $a (PubMed)16549353
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Havelka, Miroslav $7 xx0167021
- 245 10
- $a Standardisation of 54Mn and 65Zn using a software coincidence counting system / $c Havelka M, Auerbach P, Sochorová J.
- 314 __
- $a Czech Metrology Institute, Inspectorate for Ionizing Radiation, Radiová 1, 102 00 Prague, Czech Republic. mhavelka@cmi.cz
- 520 9_
- $a The activities of 54Mn and 65Zn have been determined by 4pi(PC)-gamma coincidence counting, with efficiency variation performed by the conventional method of altering the self-absorption in the sources as well as by the computer discrimination method. The standardisation of 65Zn presents some complications requiring optimisation of the gamma-ray energy window settings to achieve a linear efficiency-extrapolation curve. Determination of these optimal settings by the conventional coincidence method is a tedious task. These difficulties have been reduced by the utilisation of a software coincidence counting system that records time and amplitude information of individual pulses from coincidence measurements, where the coincidence parameters are set after the data collection process has completed, facilitating multiple data evaluations on a single data set. The optimal gamma-ray energy window settings for the 65Zn standardisation were derived from the results of the 54Mn standardisation, as well as from studies of the 65Zn data itself. The setting of the PC channel thresholds for K and both (K+L) electrons is also discussed. The results are compared with those attained using conventional coincidence counting.
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a směrnice jako téma $7 D017408
- 650 _2
- $a mangan $x analýza $x normy $7 D008345
- 650 _2
- $a dávka záření $7 D011829
- 650 _2
- $a radionuklidy $x analýza $x normy $7 D011868
- 650 _2
- $a referenční standardy $7 D012015
- 650 _2
- $a referenční hodnoty $7 D012016
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a scintilace - počítání $x metody $x normy $7 D012588
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a software $7 D012984
- 650 _2
- $a spektrometrie gama $x metody $x normy $7 D013051
- 650 _2
- $a radioizotopy zinku $x analýza $x normy $7 D015037
- 651 _2
- $a Česká republika $7 D018153
- 655 _2
- $a hodnotící studie $7 D023362
- 700 1_
- $a Auerbach, Pavel $7 xx0121907
- 700 1_
- $a Sochorová, Jana $7 xx0128926
- 773 0_
- $w MED00000499 $t Applied radiation and isotopes $g Roč. 64, č. 10-11 (2006), s. 1215-1219 $x 0969-8043
- 910 __
- $a ABA008 $b x $y 9
- 990 __
- $a 20090519102933 $b ABA008
- 991 __
- $a 20091007091737 $b ABA008
- 999 __
- $a ok $b bmc $g 656645 $s 509962
- BAS __
- $a 3
- BMC __
- $a 2006 $b 64 $c 10-11 $d 1215-1219 $i 0969-8043 $m Applied radiation and isotopes $x MED00000499
- LZP __
- $a 2009-B2/dkme