Reconstruction of the anterior cruciate ligament: dynamic strain evaluation of the graft

Handl M., Drzík M., Cerulli G., Povýsil C., Chlpík J., Varga F., Amler E., Trc T.

Language English Country Germany

E-resources Online Full text

NLK ProQuest Central from 1997-06-01 to 2023-12-31
Nursing & Allied Health Database (ProQuest) from 1997-06-01 to 2023-12-31
Health & Medicine (ProQuest) from 1997-06-01 to 2023-12-31

The study is focused on the biomechanical aspects of the anterior cruciate ligament (ACL) reconstruction procedures with an emphasis on evaluating the dynamic strain of materials commonly used for this purpose. Separate and multiple, equally tensioned strands of hamstring grafts used for the reconstruction of the ACL were biomechanically tested and compared to original ACL and bone-patellar tendon-bone (BPTB) grafts, using tissue samples from cadavers. The study was focused on measuring such material properties as the strength, stiffness, maximum load, and elongation at maximum load of the original ACL, BPTB graft, and single tendon hamstring (gracilis and semitendinosus) grafts, continued by double strands and finally by four-strand graft (STG) evaluation. Fresh-frozen cadaveric knees were used, which had been clamped and tensioned equally. The measurement was performed by drop-weight testing, using a Laser Doppler Vibrometer as a basic sensor of the dynamic movements of the gripping clamps, with parallel correlation by a piezoelectric transducer. The grafts for experiments were obtained from 21-paired knees. The measurement was performed at room temperature (21 degrees C) after 24 h of thawing at 4 degrees C. All the specimens were measured for their response to the dynamic tensile load. The maximum strength values were obtained and calculated for the appropriate section area of the specimen. The tensioned strands of the original ACL showed a maximum average load of 1,246 +/- 243 N in the section area of about 30 mm(2) (max. stress 41.3 MPa); the strands of BPTB grafts showed values of 3,855 +/- 550 N in the section area of 80 mm(2) (max. stress 40.6 MPa); the gracilis tendons showed 925 +/- 127 N in the section area of 10 mm(2) (max. stress 95.1 MPa) and the semitendinosuss yielded a result of 2,050 +/- 159 N in the area of 20 mm(2) (max. stress 88.7 MPa). Of all the materials, the original ACL have the lowest strength and stiffness in respect of their biomechanical properties. BPTB grafts showed a slightly higher value of maximum stress, while both the gracilis and semitendinosus tendons showed double the value of maximum load per section area-tensile stress. Two- and four- combined hamstring strands clamped together and equally tensioned with a drop-weight had the combined tensile strength properties of the individual strands within the estimated range of measurement errors. No significant changes in maximum loads/stresses were observed under impact loading conditions. The results of this study demonstrate that equally tensioned four-strand hamstring-tendon grafts have higher initial tensile properties than those in other varieties of samples. From a biomechanical point of view, they seem to be a reasonable alternative procedure for ACL reconstruction.

References provided by Crossref.org

000      
00000naa 2200000 a 4500
001      
bmc07527240
003      
CZ-PrNML
005      
20130608200704.0
008      
090817s2007 gw e eng||
009      
AR
024    __
$a 10.1007/s00167-006-0175-x $2 doi
035    __
$a (PubMed)16972110
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Handl, Milan, $d 1961- $7 xx0064271
245    10
$a Reconstruction of the anterior cruciate ligament: dynamic strain evaluation of the graft / $c Handl M., Drzík M., Cerulli G., Povýsil C., Chlpík J., Varga F., Amler E., Trc T.
314    __
$a Orthopedic Clinic, Charles University, University Hospital Motol, V Uvalu 84, 150 18, Prague 5, Czech Republic. milan.handl@lfmotol.cuni.cz
520    9_
$a The study is focused on the biomechanical aspects of the anterior cruciate ligament (ACL) reconstruction procedures with an emphasis on evaluating the dynamic strain of materials commonly used for this purpose. Separate and multiple, equally tensioned strands of hamstring grafts used for the reconstruction of the ACL were biomechanically tested and compared to original ACL and bone-patellar tendon-bone (BPTB) grafts, using tissue samples from cadavers. The study was focused on measuring such material properties as the strength, stiffness, maximum load, and elongation at maximum load of the original ACL, BPTB graft, and single tendon hamstring (gracilis and semitendinosus) grafts, continued by double strands and finally by four-strand graft (STG) evaluation. Fresh-frozen cadaveric knees were used, which had been clamped and tensioned equally. The measurement was performed by drop-weight testing, using a Laser Doppler Vibrometer as a basic sensor of the dynamic movements of the gripping clamps, with parallel correlation by a piezoelectric transducer. The grafts for experiments were obtained from 21-paired knees. The measurement was performed at room temperature (21 degrees C) after 24 h of thawing at 4 degrees C. All the specimens were measured for their response to the dynamic tensile load. The maximum strength values were obtained and calculated for the appropriate section area of the specimen. The tensioned strands of the original ACL showed a maximum average load of 1,246 +/- 243 N in the section area of about 30 mm(2) (max. stress 41.3 MPa); the strands of BPTB grafts showed values of 3,855 +/- 550 N in the section area of 80 mm(2) (max. stress 40.6 MPa); the gracilis tendons showed 925 +/- 127 N in the section area of 10 mm(2) (max. stress 95.1 MPa) and the semitendinosuss yielded a result of 2,050 +/- 159 N in the area of 20 mm(2) (max. stress 88.7 MPa). Of all the materials, the original ACL have the lowest strength and stiffness in respect of their biomechanical properties. BPTB grafts showed a slightly higher value of maximum stress, while both the gracilis and semitendinosus tendons showed double the value of maximum load per section area-tensile stress. Two- and four- combined hamstring strands clamped together and equally tensioned with a drop-weight had the combined tensile strength properties of the individual strands within the estimated range of measurement errors. No significant changes in maximum loads/stresses were observed under impact loading conditions. The results of this study demonstrate that equally tensioned four-strand hamstring-tendon grafts have higher initial tensile properties than those in other varieties of samples. From a biomechanical point of view, they seem to be a reasonable alternative procedure for ACL reconstruction.
650    _2
$a financování organizované $7 D005381
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a ligamentum cruciatum anterius $x fyziologie $x chirurgie $7 D016118
650    _2
$a štěp kost-čéškový vaz-kost $7 D050376
650    _2
$a mrtvola $7 D002102
650    _2
$a lidé $7 D006801
650    _2
$a lidé středního věku $7 D008875
650    _2
$a mechanický stres $7 D013314
650    _2
$a šlachy $x transplantace $7 D013710
650    _2
$a pevnost v tahu $7 D013718
650    _2
$a měniče $7 D014159
700    1_
$a Drzík, Milan. $7 _AN035828
700    1_
$a Cerulli, Giuliano
700    1_
$a Povýšil, Ctibor, $d 1943- $7 jn20001103579
700    1_
$a Chlpík, Juraj. $7 _AN037744
700    1_
$a Varga, Ferdinand, $d 1978- $7 mzk2007394831
700    1_
$a Amler, Evžen, $d 1958- $7 xx0014074
700    1_
$a Trč, Tomáš, $d 1955- $7 nlk19990073953
773    0_
$w MED00003081 $t Knee surgery, sports traumatology, arthroscopy $g Roč. 15, č. 3 (2007), s. 233-241 $x 0942-2056
910    __
$a ABA008 $b x $y 7
990    __
$a 20090726182400 $b ABA008
991    __
$a 20130608201045 $b ABA008
999    __
$a ok $b bmc $g 672267 $s 531504
BAS    __
$a 3
BMC    __
$a 2007 $b 15 $c 3 $d 233-241 $i 0942-2056 $m Knee surgery, sports traumatology, arthroscopy $x MED00003081
LZP    __
$a 2009-B3/vtme

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...