-
Something wrong with this record ?
Reconstruction of the anterior cruciate ligament: dynamic strain evaluation of the graft
Handl M., Drzík M., Cerulli G., Povýsil C., Chlpík J., Varga F., Amler E., Trc T.
Language English Country Germany
NLK
ProQuest Central
from 1997-06-01 to 2023-12-31
Nursing & Allied Health Database (ProQuest)
from 1997-06-01 to 2023-12-31
Health & Medicine (ProQuest)
from 1997-06-01 to 2023-12-31
- MeSH
- Financing, Organized MeSH
- Middle Aged MeSH
- Humans MeSH
- Anterior Cruciate Ligament physiology surgery MeSH
- Stress, Mechanical MeSH
- Transducers MeSH
- Cadaver MeSH
- Tensile Strength MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Tendons transplantation MeSH
- Bone-Patellar Tendon-Bone Grafting MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Aged, 80 and over MeSH
- Aged MeSH
The study is focused on the biomechanical aspects of the anterior cruciate ligament (ACL) reconstruction procedures with an emphasis on evaluating the dynamic strain of materials commonly used for this purpose. Separate and multiple, equally tensioned strands of hamstring grafts used for the reconstruction of the ACL were biomechanically tested and compared to original ACL and bone-patellar tendon-bone (BPTB) grafts, using tissue samples from cadavers. The study was focused on measuring such material properties as the strength, stiffness, maximum load, and elongation at maximum load of the original ACL, BPTB graft, and single tendon hamstring (gracilis and semitendinosus) grafts, continued by double strands and finally by four-strand graft (STG) evaluation. Fresh-frozen cadaveric knees were used, which had been clamped and tensioned equally. The measurement was performed by drop-weight testing, using a Laser Doppler Vibrometer as a basic sensor of the dynamic movements of the gripping clamps, with parallel correlation by a piezoelectric transducer. The grafts for experiments were obtained from 21-paired knees. The measurement was performed at room temperature (21 degrees C) after 24 h of thawing at 4 degrees C. All the specimens were measured for their response to the dynamic tensile load. The maximum strength values were obtained and calculated for the appropriate section area of the specimen. The tensioned strands of the original ACL showed a maximum average load of 1,246 +/- 243 N in the section area of about 30 mm(2) (max. stress 41.3 MPa); the strands of BPTB grafts showed values of 3,855 +/- 550 N in the section area of 80 mm(2) (max. stress 40.6 MPa); the gracilis tendons showed 925 +/- 127 N in the section area of 10 mm(2) (max. stress 95.1 MPa) and the semitendinosuss yielded a result of 2,050 +/- 159 N in the area of 20 mm(2) (max. stress 88.7 MPa). Of all the materials, the original ACL have the lowest strength and stiffness in respect of their biomechanical properties. BPTB grafts showed a slightly higher value of maximum stress, while both the gracilis and semitendinosus tendons showed double the value of maximum load per section area-tensile stress. Two- and four- combined hamstring strands clamped together and equally tensioned with a drop-weight had the combined tensile strength properties of the individual strands within the estimated range of measurement errors. No significant changes in maximum loads/stresses were observed under impact loading conditions. The results of this study demonstrate that equally tensioned four-strand hamstring-tendon grafts have higher initial tensile properties than those in other varieties of samples. From a biomechanical point of view, they seem to be a reasonable alternative procedure for ACL reconstruction.
References provided by Crossref.org
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07527240
- 003
- CZ-PrNML
- 005
- 20130608200704.0
- 008
- 090817s2007 gw e eng||
- 009
- AR
- 024 __
- $a 10.1007/s00167-006-0175-x $2 doi
- 035 __
- $a (PubMed)16972110
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Handl, Milan, $d 1961- $7 xx0064271
- 245 10
- $a Reconstruction of the anterior cruciate ligament: dynamic strain evaluation of the graft / $c Handl M., Drzík M., Cerulli G., Povýsil C., Chlpík J., Varga F., Amler E., Trc T.
- 314 __
- $a Orthopedic Clinic, Charles University, University Hospital Motol, V Uvalu 84, 150 18, Prague 5, Czech Republic. milan.handl@lfmotol.cuni.cz
- 520 9_
- $a The study is focused on the biomechanical aspects of the anterior cruciate ligament (ACL) reconstruction procedures with an emphasis on evaluating the dynamic strain of materials commonly used for this purpose. Separate and multiple, equally tensioned strands of hamstring grafts used for the reconstruction of the ACL were biomechanically tested and compared to original ACL and bone-patellar tendon-bone (BPTB) grafts, using tissue samples from cadavers. The study was focused on measuring such material properties as the strength, stiffness, maximum load, and elongation at maximum load of the original ACL, BPTB graft, and single tendon hamstring (gracilis and semitendinosus) grafts, continued by double strands and finally by four-strand graft (STG) evaluation. Fresh-frozen cadaveric knees were used, which had been clamped and tensioned equally. The measurement was performed by drop-weight testing, using a Laser Doppler Vibrometer as a basic sensor of the dynamic movements of the gripping clamps, with parallel correlation by a piezoelectric transducer. The grafts for experiments were obtained from 21-paired knees. The measurement was performed at room temperature (21 degrees C) after 24 h of thawing at 4 degrees C. All the specimens were measured for their response to the dynamic tensile load. The maximum strength values were obtained and calculated for the appropriate section area of the specimen. The tensioned strands of the original ACL showed a maximum average load of 1,246 +/- 243 N in the section area of about 30 mm(2) (max. stress 41.3 MPa); the strands of BPTB grafts showed values of 3,855 +/- 550 N in the section area of 80 mm(2) (max. stress 40.6 MPa); the gracilis tendons showed 925 +/- 127 N in the section area of 10 mm(2) (max. stress 95.1 MPa) and the semitendinosuss yielded a result of 2,050 +/- 159 N in the area of 20 mm(2) (max. stress 88.7 MPa). Of all the materials, the original ACL have the lowest strength and stiffness in respect of their biomechanical properties. BPTB grafts showed a slightly higher value of maximum stress, while both the gracilis and semitendinosus tendons showed double the value of maximum load per section area-tensile stress. Two- and four- combined hamstring strands clamped together and equally tensioned with a drop-weight had the combined tensile strength properties of the individual strands within the estimated range of measurement errors. No significant changes in maximum loads/stresses were observed under impact loading conditions. The results of this study demonstrate that equally tensioned four-strand hamstring-tendon grafts have higher initial tensile properties than those in other varieties of samples. From a biomechanical point of view, they seem to be a reasonable alternative procedure for ACL reconstruction.
- 650 _2
- $a financování organizované $7 D005381
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a senioři nad 80 let $7 D000369
- 650 _2
- $a ligamentum cruciatum anterius $x fyziologie $x chirurgie $7 D016118
- 650 _2
- $a štěp kost-čéškový vaz-kost $7 D050376
- 650 _2
- $a mrtvola $7 D002102
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a mechanický stres $7 D013314
- 650 _2
- $a šlachy $x transplantace $7 D013710
- 650 _2
- $a pevnost v tahu $7 D013718
- 650 _2
- $a měniče $7 D014159
- 700 1_
- $a Drzík, Milan. $7 _AN035828
- 700 1_
- $a Cerulli, Giuliano
- 700 1_
- $a Povýšil, Ctibor, $d 1943- $7 jn20001103579
- 700 1_
- $a Chlpík, Juraj. $7 _AN037744
- 700 1_
- $a Varga, Ferdinand, $d 1978- $7 mzk2007394831
- 700 1_
- $a Amler, Evžen, $d 1958- $7 xx0014074
- 700 1_
- $a Trč, Tomáš, $d 1955- $7 nlk19990073953
- 773 0_
- $w MED00003081 $t Knee surgery, sports traumatology, arthroscopy $g Roč. 15, č. 3 (2007), s. 233-241 $x 0942-2056
- 910 __
- $a ABA008 $b x $y 7
- 990 __
- $a 20090726182400 $b ABA008
- 991 __
- $a 20130608201045 $b ABA008
- 999 __
- $a ok $b bmc $g 672267 $s 531504
- BAS __
- $a 3
- BMC __
- $a 2007 $b 15 $c 3 $d 233-241 $i 0942-2056 $m Knee surgery, sports traumatology, arthroscopy $x MED00003081
- LZP __
- $a 2009-B3/vtme