Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Vývoj neinvazivní diagnostiky Asthma bronchiale
[Development of a non-invasive diagnostic method for bronchial asthma]

K. Syslová, J. Přech, J. Lebedová, D. Pelclová, P. Kačera

. 2009 ; 103 (3) : 224-231.

Jazyk čeština Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc07531739

A method was developed for rapid and accurate determination of cysteinylleukotrienes (LTC4, LTD4, LTE4), essential biomarkers of bronchial asthma, in exhaled breath condensate. The method consists of an immunoseparation procedure combined with selective and sensitive detection by LC-ESI-MS in the multiple reaction monitoring mode (MRM) and using a stable-isotopedilution assay. The precision of the method was around 94 %. The mean accuracy was higher than 90 % for the content of cysteinylleukotrienes in the concentrate up to 250 pg ml-1. The method was tested on patients with occupational bronchial asthma and compared with healthy subjects. The differences between the two groups were significant.

Development of a non-invasive diagnostic method for bronchial asthma

Bibliografie atd.

Lit.: 15

000      
00000naa 2200000 a 4500
001      
bmc07531739
003      
CZ-PrNML
005      
20111210152147.0
008      
091023s2009 xr e cze||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Syslová, Kamila $7 xx0145898
245    10
$a Vývoj neinvazivní diagnostiky Asthma bronchiale / $c K. Syslová, J. Přech, J. Lebedová, D. Pelclová, P. Kačera
246    11
$a Development of a non-invasive diagnostic method for bronchial asthma
314    __
$a Ústav organické technologie, Vysoká škola chemicko-technologická, Praha
504    __
$a Lit.: 15
520    9_
$a A method was developed for rapid and accurate determination of cysteinylleukotrienes (LTC4, LTD4, LTE4), essential biomarkers of bronchial asthma, in exhaled breath condensate. The method consists of an immunoseparation procedure combined with selective and sensitive detection by LC-ESI-MS in the multiple reaction monitoring mode (MRM) and using a stable-isotopedilution assay. The precision of the method was around 94 %. The mean accuracy was higher than 90 % for the content of cysteinylleukotrienes in the concentrate up to 250 pg ml-1. The method was tested on patients with occupational bronchial asthma and compared with healthy subjects. The differences between the two groups were significant.
650    _2
$a bronchiální astma $x diagnóza $7 D001249
650    _2
$a dechové testy $x metody $7 D001944
650    _2
$a leukotrieny $x analýza $7 D015289
650    _2
$a SRS-A $x analýza $7 D013189
650    _2
$a hmotnostní spektrometrie $x metody $7 D013058
650    _2
$a imunosorpční techniky $7 D007163
700    1_
$a Přech, Jan. $7 _AN039117
700    1_
$a Lebedová, Jindřiška $7 xx0062564
700    1_
$a Pelclová, Daniela, $d 1953- $7 nlk20010096163
700    1_
$a Kačer, Petr, $d 1969- $7 xx0081992
773    0_
$w MED00011010 $t Chemické listy $g Roč. 103, č. 3 (2009), s. 224-231 $x 0009-2770
856    41
$u http://chemicke-listy.cz/docs/full/2009_03_224-231.pdf $y plný text volně přístupný
910    __
$a ABA008 $b B 1918 $c 395 $y 9
990    __
$a 20091023113920 $b ABA008
991    __
$a 20091023154732 $b ABA008
999    __
$a ok $b bmc $g 690597 $s 552484
BAS    __
$a 3
BMC    __
$a 2009 $b 103 $c 3 $d 224-231 $i 0009-2770 $m Chemické listy $x MED00011010
LZP    __
$a 2009-44/dkmv

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...