-
Je něco špatně v tomto záznamu ?
Vývoj neinvazivní diagnostiky Asthma bronchiale
[Development of a non-invasive diagnostic method for bronchial asthma]
K. Syslová, J. Přech, J. Lebedová, D. Pelclová, P. Kačera
Jazyk čeština Země Česko
- MeSH
- bronchiální astma diagnóza MeSH
- dechové testy metody MeSH
- hmotnostní spektrometrie metody MeSH
- imunosorpční techniky MeSH
- leukotrieny analýza MeSH
- SRS-A analýza MeSH
A method was developed for rapid and accurate determination of cysteinylleukotrienes (LTC4, LTD4, LTE4), essential biomarkers of bronchial asthma, in exhaled breath condensate. The method consists of an immunoseparation procedure combined with selective and sensitive detection by LC-ESI-MS in the multiple reaction monitoring mode (MRM) and using a stable-isotopedilution assay. The precision of the method was around 94 %. The mean accuracy was higher than 90 % for the content of cysteinylleukotrienes in the concentrate up to 250 pg ml-1. The method was tested on patients with occupational bronchial asthma and compared with healthy subjects. The differences between the two groups were significant.
Development of a non-invasive diagnostic method for bronchial asthma
Lit.: 15
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07531739
- 003
- CZ-PrNML
- 005
- 20111210152147.0
- 008
- 091023s2009 xr e cze||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Syslová, Kamila $7 xx0145898
- 245 10
- $a Vývoj neinvazivní diagnostiky Asthma bronchiale / $c K. Syslová, J. Přech, J. Lebedová, D. Pelclová, P. Kačera
- 246 11
- $a Development of a non-invasive diagnostic method for bronchial asthma
- 314 __
- $a Ústav organické technologie, Vysoká škola chemicko-technologická, Praha
- 504 __
- $a Lit.: 15
- 520 9_
- $a A method was developed for rapid and accurate determination of cysteinylleukotrienes (LTC4, LTD4, LTE4), essential biomarkers of bronchial asthma, in exhaled breath condensate. The method consists of an immunoseparation procedure combined with selective and sensitive detection by LC-ESI-MS in the multiple reaction monitoring mode (MRM) and using a stable-isotopedilution assay. The precision of the method was around 94 %. The mean accuracy was higher than 90 % for the content of cysteinylleukotrienes in the concentrate up to 250 pg ml-1. The method was tested on patients with occupational bronchial asthma and compared with healthy subjects. The differences between the two groups were significant.
- 650 _2
- $a bronchiální astma $x diagnóza $7 D001249
- 650 _2
- $a dechové testy $x metody $7 D001944
- 650 _2
- $a leukotrieny $x analýza $7 D015289
- 650 _2
- $a SRS-A $x analýza $7 D013189
- 650 _2
- $a hmotnostní spektrometrie $x metody $7 D013058
- 650 _2
- $a imunosorpční techniky $7 D007163
- 700 1_
- $a Přech, Jan. $7 _AN039117
- 700 1_
- $a Lebedová, Jindřiška $7 xx0062564
- 700 1_
- $a Pelclová, Daniela, $d 1953- $7 nlk20010096163
- 700 1_
- $a Kačer, Petr, $d 1969- $7 xx0081992
- 773 0_
- $w MED00011010 $t Chemické listy $g Roč. 103, č. 3 (2009), s. 224-231 $x 0009-2770
- 856 41
- $u http://chemicke-listy.cz/docs/full/2009_03_224-231.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1918 $c 395 $y 9
- 990 __
- $a 20091023113920 $b ABA008
- 991 __
- $a 20091023154732 $b ABA008
- 999 __
- $a ok $b bmc $g 690597 $s 552484
- BAS __
- $a 3
- BMC __
- $a 2009 $b 103 $c 3 $d 224-231 $i 0009-2770 $m Chemické listy $x MED00011010
- LZP __
- $a 2009-44/dkmv