Analýza proteinů pomocí automatické čipové elektroforézy expersion a porovnání s metodou SDS-PAGE
[Protein analysis using automated experion chip electrophoresis and its comparison with SDS-PAGE]

Jan Bárta, Veronika Bártová, Vladislav Čurn

. 2010 ; 104 (1) : 33-40.

Jazyk čeština Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc10008216

Two methods recommended for analysis of denatured proteins, automated Experion chip electrophoresis and SDS-PAGE, are compared. The Experion method is a novel technique based on combination of the LabChip microfluidic separation technique (Caliper Life Sciences) and sensitive fluorescent detection. Both methods were compared in molecular weight (MW) determination of a protein standard mixture, resolution of protein pairs of near molecular weights and estimation of the abundance of a target protein in the mixture to be purified. Both the methods are appropriate for MW determination and in purification of proteins. The accuracy of the methods is approximately the same (ca. 8 %), but the Experion method shows better reproducibility (ca. 1.48 %) than SDS-PAGE (ca. 2.17 %).

Protein analysis using automated experion chip electrophoresis and its comparison with SDS-PAGE

Bibliografie atd.

Lit.: 40

000      
00000naa 2200000 a 4500
001      
bmc10008216
003      
CZ-PrNML
005      
20111210162014.0
008      
100409s2010 xr e cze||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Bárta, Jan. $7 _AN047174
245    10
$a Analýza proteinů pomocí automatické čipové elektroforézy expersion a porovnání s metodou SDS-PAGE / $c Jan Bárta, Veronika Bártová, Vladislav Čurn
246    11
$a Protein analysis using automated experion chip electrophoresis and its comparison with SDS-PAGE
314    __
$a Katedra rostlinné výroby a agroekologie, Zemědělská fakulta, Jihočeská univerzita, České Budějovice
504    __
$a Lit.: 40
520    9_
$a Two methods recommended for analysis of denatured proteins, automated Experion chip electrophoresis and SDS-PAGE, are compared. The Experion method is a novel technique based on combination of the LabChip microfluidic separation technique (Caliper Life Sciences) and sensitive fluorescent detection. Both methods were compared in molecular weight (MW) determination of a protein standard mixture, resolution of protein pairs of near molecular weights and estimation of the abundance of a target protein in the mixture to be purified. Both the methods are appropriate for MW determination and in purification of proteins. The accuracy of the methods is approximately the same (ca. 8 %), but the Experion method shows better reproducibility (ca. 1.48 %) than SDS-PAGE (ca. 2.17 %).
650    _2
$a proteiny $x analýza $7 D011506
650    _2
$a elektroforéza mikročipová $x metody $x přístrojové vybavení $7 D046209
650    _2
$a elektroforéza v polyakrylamidovém gelu $x metody $x přístrojové vybavení $7 D004591
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a financování organizované $7 D005381
700    1_
$a Bártová, Veronika. $7 ola2010548299
700    1_
$a Čurn, Vladislav, $d 1965- $7 xx0064513
773    0_
$w MED00011010 $t Chemické listy $g Roč. 104, č. 1 (2010), s. 33-40 $x 0009-2770
856    41
$u http://www.chemicke-listy.cz/docs/full/2010_01_33-40.pdf $y plný text volně přístupný
910    __
$a ABA008 $b B 1918 $c 395 $y 8
990    __
$a 20100408105345 $b ABA008
991    __
$a 20100409064253 $b ABA008
999    __
$a ok $b bmc $g 722111 $s 585199
BAS    __
$a 3
BMC    __
$a 2010 $b 104 $c 1 $d 33-40 $i 0009-2770 $m Chemické listy $x MED00011010
LZP    __
$a 2010-18/ipmv

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...