Je něco špatně v tomto záznamu ?
Analýza proteinů pomocí automatické čipové elektroforézy expersion a porovnání s metodou SDS-PAGE
[Protein analysis using automated experion chip electrophoresis and its comparison with SDS-PAGE]
Jan Bárta, Veronika Bártová, Vladislav Čurn
Jazyk čeština Země Česko
- MeSH
- elektroforéza mikročipová metody přístrojové vybavení MeSH
- elektroforéza v polyakrylamidovém gelu metody přístrojové vybavení MeSH
- financování organizované MeSH
- proteiny analýza MeSH
- reprodukovatelnost výsledků MeSH
Two methods recommended for analysis of denatured proteins, automated Experion chip electrophoresis and SDS-PAGE, are compared. The Experion method is a novel technique based on combination of the LabChip microfluidic separation technique (Caliper Life Sciences) and sensitive fluorescent detection. Both methods were compared in molecular weight (MW) determination of a protein standard mixture, resolution of protein pairs of near molecular weights and estimation of the abundance of a target protein in the mixture to be purified. Both the methods are appropriate for MW determination and in purification of proteins. The accuracy of the methods is approximately the same (ca. 8 %), but the Experion method shows better reproducibility (ca. 1.48 %) than SDS-PAGE (ca. 2.17 %).
Protein analysis using automated experion chip electrophoresis and its comparison with SDS-PAGE
Lit.: 40
- 000
- 00000naa 2200000 a 4500
- 001
- bmc10008216
- 003
- CZ-PrNML
- 005
- 20111210162014.0
- 008
- 100409s2010 xr e cze||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Bárta, Jan. $7 _AN047174
- 245 10
- $a Analýza proteinů pomocí automatické čipové elektroforézy expersion a porovnání s metodou SDS-PAGE / $c Jan Bárta, Veronika Bártová, Vladislav Čurn
- 246 11
- $a Protein analysis using automated experion chip electrophoresis and its comparison with SDS-PAGE
- 314 __
- $a Katedra rostlinné výroby a agroekologie, Zemědělská fakulta, Jihočeská univerzita, České Budějovice
- 504 __
- $a Lit.: 40
- 520 9_
- $a Two methods recommended for analysis of denatured proteins, automated Experion chip electrophoresis and SDS-PAGE, are compared. The Experion method is a novel technique based on combination of the LabChip microfluidic separation technique (Caliper Life Sciences) and sensitive fluorescent detection. Both methods were compared in molecular weight (MW) determination of a protein standard mixture, resolution of protein pairs of near molecular weights and estimation of the abundance of a target protein in the mixture to be purified. Both the methods are appropriate for MW determination and in purification of proteins. The accuracy of the methods is approximately the same (ca. 8 %), but the Experion method shows better reproducibility (ca. 1.48 %) than SDS-PAGE (ca. 2.17 %).
- 650 _2
- $a proteiny $x analýza $7 D011506
- 650 _2
- $a elektroforéza mikročipová $x metody $x přístrojové vybavení $7 D046209
- 650 _2
- $a elektroforéza v polyakrylamidovém gelu $x metody $x přístrojové vybavení $7 D004591
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Bártová, Veronika. $7 ola2010548299
- 700 1_
- $a Čurn, Vladislav, $d 1965- $7 xx0064513
- 773 0_
- $w MED00011010 $t Chemické listy $g Roč. 104, č. 1 (2010), s. 33-40 $x 0009-2770
- 856 41
- $u http://www.chemicke-listy.cz/docs/full/2010_01_33-40.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1918 $c 395 $y 8
- 990 __
- $a 20100408105345 $b ABA008
- 991 __
- $a 20100409064253 $b ABA008
- 999 __
- $a ok $b bmc $g 722111 $s 585199
- BAS __
- $a 3
- BMC __
- $a 2010 $b 104 $c 1 $d 33-40 $i 0009-2770 $m Chemické listy $x MED00011010
- LZP __
- $a 2010-18/ipmv