The possibilities and limitations of hydrodensitometry and its position among the methods of body composition assessment [Možnosti a limity metódy hydrodenzitometrie a jej miesto medzi metódami hodnotenia telesného zloženia]

Lucia Malá, František Zahálka, Tomáš Malý

Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc10012474

A theoretical study of hydrodensitometry which has long been considered the gold-standard reference method for the assessment of body composition. The paper describes the principle of underwater weighing; the authors argue about the suitability of its present day application, about its positives and negatives, they present studies, in which hydrodensitometry was compared with the DEXA reference method. In conclusion, the authors present Air Displacement Pletysmography as a more accurate and more comfortable follow-up to the underwater weighing method, but still recommend hydrodensitometry as one of the most powerful reference methods for the assessment of body composition.

Možnosti a limity metódy hydrodenzitometrie a jej miesto medzi metódami hodnotenia telesného zloženia

Bibliografie atd.

Lit.: 36

000      
00000naa 2200000 a 4500
001      
bmc10012474
003      
CZ-PrNML
005      
20120207151128.0
008      
100524s2008 xr e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng $b slo
044    __
$a xr
100    1_
$a Malá, Lucia $7 xx0157706
245    14
$a The possibilities and limitations of hydrodensitometry and its position among the methods of body composition assessment / $c Lucia Malá, František Zahálka, Tomáš Malý
246    11
$a Možnosti a limity metódy hydrodenzitometrie a jej miesto medzi metódami hodnotenia telesného zloženia
314    __
$a Charles University in Prague, Faculty of Physical Education and Sport
504    __
$a Lit.: 36
520    9_
$a A theoretical study of hydrodensitometry which has long been considered the gold-standard reference method for the assessment of body composition. The paper describes the principle of underwater weighing; the authors argue about the suitability of its present day application, about its positives and negatives, they present studies, in which hydrodensitometry was compared with the DEXA reference method. In conclusion, the authors present Air Displacement Pletysmography as a more accurate and more comfortable follow-up to the underwater weighing method, but still recommend hydrodensitometry as one of the most powerful reference methods for the assessment of body composition.
650    _2
$a denzitometrie $x metody $x využití $7 D003720
650    _2
$a složení těla $x fyziologie $7 D001823
650    _2
$a pletysmografie $x metody $x využití $7 D010991
650    _2
$a antropometrie $x metody $x přístrojové vybavení $7 D000886
650    _2
$a absorpční fotometrie $x metody $x využití $7 D015502
650    _2
$a elektrická impedance $x diagnostické užití $7 D017097
650    _2
$a počítačová rentgenová tomografie $x metody $x využití $7 D014057
650    _2
$a klinické laboratorní techniky $x přístrojové vybavení $x využití $7 D019411
650    _2
$a hodnocení biomedicínských technologií $x metody $x využití $7 D013673
650    _2
$a lidé $7 D006801
650    _2
$a financování organizované $7 D005381
700    1_
$a Zahálka, František, $d 1961- $7 mzk2005274933
700    1_
$a Malý, Tomáš $7 xx0159323
773    0_
$w MED00150734 $t Acta Universitatis Carolinae. Kinanthropologica $g Roč. 44, č. 2 (2008), s. 57-66 $x 1212-1428
910    __
$a ABA008 $y 8 $b A 1212 $c 865
990    __
$a 20100524142959 $b ABA008
991    __
$a 20100629160357 $b ABA008
999    __
$a ok $b bmc $g 726331 $s 589484
BAS    __
$a 3
BMC    __
$a 2008 $b 44 $c 2 $m Acta Universitatis Carolinae. Kinanthropologica $x MED00150734 $d 57-66
LZP    __
$a 2010-27/vtal

Najít záznam