Comparison of wave-equation versus measurement-processing transducer calibration for ultrasonic transmission tomography

J. Zacal, D. Hemzal, J. Jan, A. Filipik, R. Jirik, R. Kolar

Jazyk angličtina Země Spojené státy americké

Typ dokumentu srovnávací studie, hodnotící studie, validační studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc10026766

The contribution deals with the first step in using proper wave-equation based ultrasound propagation model in image reconstruction from the ultrasonic computed tomography data. Particularly, it compares the transducer calibration results obtained via direct measurement of the empty image field and consequential data processing based on a simple direct-propagation model with the simulation results obtained via solving the single-frequency wave equation under proper border conditions reflecting the realistic measurement geometry. The results show a reasonable qualitative agreement when a certain degree of phase-shifted coupling from the transmitting transducer elements to the neighbouring elements of the transducer field is admitted.

000      
00000naa 2200000 a 4500
001      
bmc10026766
003      
CZ-PrNML
005      
20121025221920.0
008      
101019s2006 xxu e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Začal, Jiří. $7 _AN033538
245    10
$a Comparison of wave-equation versus measurement-processing transducer calibration for ultrasonic transmission tomography / $c J. Zacal, D. Hemzal, J. Jan, A. Filipik, R. Jirik, R. Kolar
314    __
$a Dept. of Biomed. Eng., Brno Univ. of Technol., Czech Republic. zacal@feec.vutbr.cz
520    9_
$a The contribution deals with the first step in using proper wave-equation based ultrasound propagation model in image reconstruction from the ultrasonic computed tomography data. Particularly, it compares the transducer calibration results obtained via direct measurement of the empty image field and consequential data processing based on a simple direct-propagation model with the simulation results obtained via solving the single-frequency wave equation under proper border conditions reflecting the realistic measurement geometry. The results show a reasonable qualitative agreement when a certain degree of phase-shifted coupling from the transmitting transducer elements to the neighbouring elements of the transducer field is admitted.
650    _2
$a algoritmy $7 D000465
650    _2
$a kalibrace $7 D002138
650    _2
$a vylepšení obrazu $x metody $x normy $7 D007089
650    _2
$a interpretace obrazu počítačem $x metody $x normy $7 D007090
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a radiační rozptyl $7 D012542
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a měniče $7 D014159
650    _2
$a ultrasonografie $x normy $x přístrojové vybavení $7 D014463
650    _2
$a financování organizované $7 D005381
651    _2
$a Česká republika $7 D018153
655    _2
$a srovnávací studie $7 D003160
655    _2
$a hodnotící studie $7 D023362
655    _2
$a validační studie $7 D023361
700    1_
$a Hemzal, Dušan. $7 mub2012737085
700    1_
$a Jan, Jiří, $d 1941- $7 jn20000710059
700    1_
$a Filipík, Adam. $7 _AN054778
700    1_
$a Jiřík, Radovan. $7 xx0241067
700    1_
$a Kolář, Radim, $d 1975- $7 mzk2003165628
773    0_
$t Conf Proc IEEE Eng Med Biol Soc. $w MED00180111 $g Roč. 1(2006), s. 2754-2757 $x 1557-170X
910    __
$a ABA008 $b x $y 7
990    __
$a 20110413103034 $b ABA008
991    __
$a 20121025222133 $b ABA008
999    __
$a ok $b bmc $g 801871 $s 666631
BAS    __
$a 3
BMC    __
$a 2006 $d 2754-2757 $i 1557-170X $m Conference proceedings ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society $n Conf Proc IEEE Eng Med Biol Soc $b 1 $x MED00180111
LZP    __
$a 2010-B3/vtme

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...