Two novel chromatographic methods both based on utilization of sub-2-micron particle columns were developed for the analysis of phenolic compounds in this work. An HPLC system was equipped with C(18) silica-based analytical column (50 mm x 4.6 mm, 1.8 microm) and a UPLC system with ethylene-bridged hybrid C(18) analytical column (100 mm x 2.1 mm, 1.7 microm). In total 34 phenolic substances were divided into groups of phenolic acids, flavonoids, catechins and coumarins and were analysed in sequence using different gradient methods. System suitability test data, including repeatability of retention time and peak area, mean values of asymmetry factor, resolution, peak capacity and the height equivalent of a theoretical plate were determined for each gradient method by 10 replicate injections. The developed methods were applied in the analysis of real samples (grape wines, teas).

Citace poskytuje Crossref.org

000      
02167naa 2200325 a 4500
001      
bmc11004092
003      
CZ-PrNML
005      
20130204145542.0
008      
110303s2008 xxk e eng||
009      
AR
024    __
$a 10.1016/j.talanta.2008.02.021 $2 doi
035    __
$a (PubMed)18585262
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Spáčil, Zdeněk, $d 1982- $7 mzk2007411147
245    10
$a Analysis of phenolic compounds by high performance liquid chromatography and ultra performance liquid chromatography / $c Z Spacil, L Novakova, P Solich
314    __
$a Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovskeho 1203, 500 05 Hradec Kralove, Czech Republic.
520    9_
$a Two novel chromatographic methods both based on utilization of sub-2-micron particle columns were developed for the analysis of phenolic compounds in this work. An HPLC system was equipped with C(18) silica-based analytical column (50 mm x 4.6 mm, 1.8 microm) and a UPLC system with ethylene-bridged hybrid C(18) analytical column (100 mm x 2.1 mm, 1.7 microm). In total 34 phenolic substances were divided into groups of phenolic acids, flavonoids, catechins and coumarins and were analysed in sequence using different gradient methods. System suitability test data, including repeatability of retention time and peak area, mean values of asymmetry factor, resolution, peak capacity and the height equivalent of a theoretical plate were determined for each gradient method by 10 replicate injections. The developed methods were applied in the analysis of real samples (grape wines, teas).
650    _2
$a katechin $x analýza $7 D002392
650    _2
$a chromatografie kapalinová $x metody $7 D002853
650    _2
$a kumariny $x analýza $7 D003374
650    _2
$a flavonoidy $x analýza $7 D005419
650    _2
$a hydroxybenzoáty $x analýza $x chemie $7 D062385
650    _2
$a teplota $7 D013696
650    _2
$a časové faktory $7 D013997
650    _2
$a financování organizované $7 D005381
700    1_
$a Nováková, Lucie, $d 1979- $7 xx0048951
700    1_
$a Solich, Petr, $d 1955- $7 jo2007285395
773    0_
$t Talanta $w MED00004484 $g Roč. 76, č. 1 (2008), s. 189-199
910    __
$a ABA008 $b x $y 1
990    __
$a 20110413123157 $b ABA008
991    __
$a 20121126114146 $b ABA008
999    __
$a ok $b bmc $g 831432 $s 696120
BAS    __
$a 3
BMC    __
$a 2008 $b 76 $c 1 $d 189-199 $m Talanta $n Talanta $x MED00004484
LZP    __
$a 2011-3B/ipme

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé