Analysis of phenolic compounds by high performance liquid chromatography and ultra performance liquid chromatography
Z Spacil, L Novakova, P Solich
Jazyk angličtina Země Velká Británie
- MeSH
- časové faktory MeSH
- chromatografie kapalinová metody MeSH
- financování organizované MeSH
- flavonoidy analýza MeSH
- hydroxybenzoáty analýza chemie MeSH
- katechin analýza MeSH
- kumariny analýza MeSH
- teplota MeSH
Two novel chromatographic methods both based on utilization of sub-2-micron particle columns were developed for the analysis of phenolic compounds in this work. An HPLC system was equipped with C(18) silica-based analytical column (50 mm x 4.6 mm, 1.8 microm) and a UPLC system with ethylene-bridged hybrid C(18) analytical column (100 mm x 2.1 mm, 1.7 microm). In total 34 phenolic substances were divided into groups of phenolic acids, flavonoids, catechins and coumarins and were analysed in sequence using different gradient methods. System suitability test data, including repeatability of retention time and peak area, mean values of asymmetry factor, resolution, peak capacity and the height equivalent of a theoretical plate were determined for each gradient method by 10 replicate injections. The developed methods were applied in the analysis of real samples (grape wines, teas).
Citace poskytuje Crossref.org
- 000
- 02167naa 2200325 a 4500
- 001
- bmc11004092
- 003
- CZ-PrNML
- 005
- 20130204145542.0
- 008
- 110303s2008 xxk e eng||
- 009
- AR
- 024 __
- $a 10.1016/j.talanta.2008.02.021 $2 doi
- 035 __
- $a (PubMed)18585262
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Spáčil, Zdeněk, $d 1982- $7 mzk2007411147
- 245 10
- $a Analysis of phenolic compounds by high performance liquid chromatography and ultra performance liquid chromatography / $c Z Spacil, L Novakova, P Solich
- 314 __
- $a Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovskeho 1203, 500 05 Hradec Kralove, Czech Republic.
- 520 9_
- $a Two novel chromatographic methods both based on utilization of sub-2-micron particle columns were developed for the analysis of phenolic compounds in this work. An HPLC system was equipped with C(18) silica-based analytical column (50 mm x 4.6 mm, 1.8 microm) and a UPLC system with ethylene-bridged hybrid C(18) analytical column (100 mm x 2.1 mm, 1.7 microm). In total 34 phenolic substances were divided into groups of phenolic acids, flavonoids, catechins and coumarins and were analysed in sequence using different gradient methods. System suitability test data, including repeatability of retention time and peak area, mean values of asymmetry factor, resolution, peak capacity and the height equivalent of a theoretical plate were determined for each gradient method by 10 replicate injections. The developed methods were applied in the analysis of real samples (grape wines, teas).
- 650 _2
- $a katechin $x analýza $7 D002392
- 650 _2
- $a chromatografie kapalinová $x metody $7 D002853
- 650 _2
- $a kumariny $x analýza $7 D003374
- 650 _2
- $a flavonoidy $x analýza $7 D005419
- 650 _2
- $a hydroxybenzoáty $x analýza $x chemie $7 D062385
- 650 _2
- $a teplota $7 D013696
- 650 _2
- $a časové faktory $7 D013997
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Nováková, Lucie, $d 1979- $7 xx0048951
- 700 1_
- $a Solich, Petr, $d 1955- $7 jo2007285395
- 773 0_
- $t Talanta $w MED00004484 $g Roč. 76, č. 1 (2008), s. 189-199
- 910 __
- $a ABA008 $b x $y 1
- 990 __
- $a 20110413123157 $b ABA008
- 991 __
- $a 20121126114146 $b ABA008
- 999 __
- $a ok $b bmc $g 831432 $s 696120
- BAS __
- $a 3
- BMC __
- $a 2008 $b 76 $c 1 $d 189-199 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a 2011-3B/ipme