Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Three-dimensional electrogram in spherical coordinates: application to ischemia analysis

O. Janoušek, J. Kolářová, M. Nováková, I. Provazník

. 2010 ; 59 (Suppl. 1) : S51-S58.

Jazyk angličtina Země Česko

Typ dokumentu přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc11004392

Three-dimensional electrogram was used for analysis of ischemia manifestation in isolated hearts. Three parameters based on spherical coordination system were used in this study – amplitude of electrical heart vector, its azimuth and elevation. The parameters were presented as a trend. This approach reflected ischemic changes in a manner which can be easily observed and evaluated. Ischemia was analysed in seven isolated hearts of New Zealand white rabbits. It was found that (a) ischemia changes heart electric vector, (b) ischemic preconditioning has a protective effect, and (c) both of these findings can be clearly observed by the proposed method.

Citace poskytuje Crossref.org

Methods in Experimental and Clinical Cardiovascular Research. 37th Workshop of the Committee of Experimental Cardiology, Blansko, 2010

Bibliografie atd.

Lit.: 18

000      
00000naa 2200000 a 4500
001      
bmc11004392
003      
CZ-PrNML
005      
20151006142029.0
008      
110308s2010 xr e eng||
009      
AR
024    7_
$a 10.33549/physiolres.932013 $2 doi
035    __
$a (PubMed)20626220
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Janoušek, Oto. $7 mzk2014840916
245    10
$a Three-dimensional electrogram in spherical coordinates: application to ischemia analysis / $c O. Janoušek, J. Kolářová, M. Nováková, I. Provazník
314    __
$a Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno
500    __
$a Methods in Experimental and Clinical Cardiovascular Research. 37th Workshop of the Committee of Experimental Cardiology, Blansko, 2010
504    __
$a Lit.: 18
520    9_
$a Three-dimensional electrogram was used for analysis of ischemia manifestation in isolated hearts. Three parameters based on spherical coordination system were used in this study – amplitude of electrical heart vector, its azimuth and elevation. The parameters were presented as a trend. This approach reflected ischemic changes in a manner which can be easily observed and evaluated. Ischemia was analysed in seven isolated hearts of New Zealand white rabbits. It was found that (a) ischemia changes heart electric vector, (b) ischemic preconditioning has a protective effect, and (c) both of these findings can be clearly observed by the proposed method.
650    _2
$a financování organizované $7 D005381
650    _2
$a akční potenciály $7 D000200
650    _2
$a zvířata $7 D000818
650    _2
$a modely nemocí na zvířatech $7 D004195
650    _2
$a elektrofyziologické techniky kardiologické $7 D022062
650    _2
$a interpretace obrazu počítačem $7 D007090
650    _2
$a zobrazování trojrozměrné $7 D021621
650    _2
$a ischemické přivykání $7 D019157
650    _2
$a modely kardiovaskulární $7 D008955
650    _2
$a ischemická choroba srdeční $x diagnóza $x prevence a kontrola $7 D017202
650    _2
$a prediktivní hodnota testů $7 D011237
650    _2
$a králíci $7 D011817
650    _2
$a vektorkardiografie $7 D014672
655    _2
$a přehledy $7 D016454
700    1_
$a Kolářová, J. $7 _AN058469
700    1_
$a Nováková, Marie, $d 1965- $7 xx0006795
700    1_
$a Provazník, Ivo, $d 1968- $7 mzk2002106297
773    0_
$w MED00003824 $t Physiological research $g Roč. 59,Suppl. 1 (2010), s. S51-S58 $x 0862-8408
773    0_
$t Methods in experimental and clinical cardiovascular research $g Roč. 59,Suppl. 1 (2010), s. S51-S58 $w MED00178497
856    41
$u http://www.biomed.cas.cz/physiolres/pdf/59%20Suppl%201/59_S51.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 4120 $c 266 $y 1 $z 0
990    __
$a 20110303103805 $b ABA008
991    __
$a 20151006142214 $b ABA008
999    __
$a ok $b bmc $g 831749 $s 696425
BAS    __
$a 3
BMC    __
$a 2010 $b 59 $c Suppl. 1 $d S51-S58 $m Physiological research $x MED00003824
BMC    __
$a 2010 $b 59 $c Suppl. 1 $d S51-S58 $m Methods in experimental and clinical cardiovascular research $x MED00178497
LZP    __
$a 2011-14/ipme

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé