• Something wrong with this record ?

A new approach to automated assessment of fractionation of endocardial electrograms during atrial fibrillation

V Kremen, L Lhotska, M Macas, R Cihak, V Vancura, J Kautzner, D Wichterle

. 2008 ; 29 (12) : 1371-1381.

Language English Country Great Britain

Document type Research Support, Non-U.S. Gov't

Complex fractionated atrial electrograms (CFAEs) may represent the electrophysiological substrate for atrial fibrillation (AF). Progress in signal processing algorithms to identify sites of CFAEs is crucial for the development of AF ablation strategies. A novel algorithm for automated description of fractionation of atrial electrograms (A-EGMs) based on the wavelet transform has been proposed. The algorithm was developed and validated using a representative set of 1.5 s A-EGM (n = 113) ranked by three experts into four categories: 1-organized atrial activity; 2-mild; 3-intermediate; 4-high degree of fractionation. A tight relationship between a fractionation index and expert classification of A-EGMs (Spearman correlation rho = 0.87) was documented with a sensitivity of 82% and specificity of 90% for the identification of highly fractionated A-EGMs. This operator-independent description of A-EGM complexity may be easily incorporated into mapping systems to facilitate CFAE identification and to guide AF substrate ablation.

000      
02631naa 2200433 a 4500
001      
bmc11006238
003      
CZ-PrNML
005      
20120713111217.0
008      
110401s2008 xxk e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Křemen, Václav. $7 _AN068418
245    12
$a A new approach to automated assessment of fractionation of endocardial electrograms during atrial fibrillation / $c V Kremen, L Lhotska, M Macas, R Cihak, V Vancura, J Kautzner, D Wichterle
314    __
$a Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University, Prague, Czech Republic. xkremen@fel.cvut.cz
520    9_
$a Complex fractionated atrial electrograms (CFAEs) may represent the electrophysiological substrate for atrial fibrillation (AF). Progress in signal processing algorithms to identify sites of CFAEs is crucial for the development of AF ablation strategies. A novel algorithm for automated description of fractionation of atrial electrograms (A-EGMs) based on the wavelet transform has been proposed. The algorithm was developed and validated using a representative set of 1.5 s A-EGM (n = 113) ranked by three experts into four categories: 1-organized atrial activity; 2-mild; 3-intermediate; 4-high degree of fractionation. A tight relationship between a fractionation index and expert classification of A-EGMs (Spearman correlation rho = 0.87) was documented with a sensitivity of 82% and specificity of 90% for the identification of highly fractionated A-EGMs. This operator-independent description of A-EGM complexity may be easily incorporated into mapping systems to facilitate CFAE identification and to guide AF substrate ablation.
590    __
$a bohemika - dle Pubmed
650    _2
$a senioři $7 D000368
650    _2
$a algoritmy $7 D000465
650    _2
$a fibrilace síní $x patofyziologie $7 D001281
650    _2
$a automatizace $7 D001331
650    _2
$a katetrizační ablace $7 D017115
650    _2
$a interpretace statistických dat $7 D003627
650    _2
$a elektrokardiografie $x statistika a číselné údaje $7 D004562
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a pilotní projekty $7 D010865
650    _2
$a počítačové zpracování signálu $7 D012815
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Lhotská, Lenka, $d 1961- $7 ntka173228
700    1_
$a Macaš, Martin, $d 1981- $7 xx0152822
700    1_
$a Čihák, Robert $7 xx0061374
700    1_
$a Vančura, Vlastimil $7 xx0060367
700    1_
$a Kautzner, Josef, $d 1957- $7 xx0037112
700    1_
$a Wichterle, Dan $7 xx0101417
773    0_
$t Physiological Measurement $w MED00181057 $g Roč. 29, č. 12 (2008), s. 1371-1381 $x 0967-3334
910    __
$a ABA008 $b x $y 2
990    __
$a 20110414101845 $b ABA008
991    __
$a 20120713111132 $b ABA008
999    __
$a ok $b bmc $g 833845 $s 698330
BAS    __
$a 3
BMC    __
$a 2008 $x MED00181057 $b 29 $c 12 $d 1371-1381 $i 0967-3334 $m Physiological measurement $n Physiol Meas
LZP    __
$a 2011-1B09/dkjp

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...