Selected ion flow tube mass spectrometry of exhaled breath condensate headspace

P Cap, K Dryahina, F Pehal, P Spanel

. 2008 ; 22 (18) : 2844-2850.

Jazyk angličtina Země Velká Británie

Perzistentní odkaz   https://www.medvik.cz/link/bmc11006814
E-zdroje Online

NLK Wiley Online Library (archiv) od 1996-01-01 do 2012-12-31

Collection of exhaled breath condensate (EBC) is a relatively simple noninvasive method of breath analysis; however, no data have been reported that would relate concentration of volatile compounds in EBC to their gaseous concentrations in exhaled air. The aim of the study was to investigate which volatile compounds are present in EBC and how their concentrations relate to results of direct breath analysis. Thus, samples of EBC were collected in a standard way from several subjects and absolute levels of several common volatile breath metabolites (ammonia, acetone, ethanol, methanol, propanol, isoprene, hydrogen cyanide, formaldehyde and acetaldehyde) were then determined in their headspace using selected ion flow tube mass spectrometry (SIFT-MS). Results are compared with those from on-line breath analyses carried out immediately before collecting the EBC samples. It has been demonstrated that SIFT-MS can be used to quantify the concentrations of volatiles in EBC samples and that, for methanol, ammonia, ethanol and acetone, the EBC concentrations correlate with the direct breath levels. However, the EBC concentrations of isoprene, formaldehyde, acetaldehyde, hydrogen cyanide and propanol do not correlate with direct breath measurements. Copyright (c) 2008 John Wiley & Sons, Ltd.

000      
03072naa 2200421 a 4500
001      
bmc11006814
003      
CZ-PrNML
005      
20111210203339.0
008      
110406s2008 xxk e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Čáp, Petr $7 xx0043549
245    10
$a Selected ion flow tube mass spectrometry of exhaled breath condensate headspace / $c P Cap, K Dryahina, F Pehal, P Spanel
314    __
$a Department of Allergology and Clinical Immunology, Hospital Na Homolce, Institute for Postgraduate Medical Education, Prague, Czech Republic.
520    9_
$a Collection of exhaled breath condensate (EBC) is a relatively simple noninvasive method of breath analysis; however, no data have been reported that would relate concentration of volatile compounds in EBC to their gaseous concentrations in exhaled air. The aim of the study was to investigate which volatile compounds are present in EBC and how their concentrations relate to results of direct breath analysis. Thus, samples of EBC were collected in a standard way from several subjects and absolute levels of several common volatile breath metabolites (ammonia, acetone, ethanol, methanol, propanol, isoprene, hydrogen cyanide, formaldehyde and acetaldehyde) were then determined in their headspace using selected ion flow tube mass spectrometry (SIFT-MS). Results are compared with those from on-line breath analyses carried out immediately before collecting the EBC samples. It has been demonstrated that SIFT-MS can be used to quantify the concentrations of volatiles in EBC samples and that, for methanol, ammonia, ethanol and acetone, the EBC concentrations correlate with the direct breath levels. However, the EBC concentrations of isoprene, formaldehyde, acetaldehyde, hydrogen cyanide and propanol do not correlate with direct breath measurements. Copyright (c) 2008 John Wiley & Sons, Ltd.
650    _2
$a dechové testy $x metody $x přístrojové vybavení $7 D001944
650    _2
$a design vybavení $7 D004867
650    _2
$a analýza selhání vybavení $7 D019544
650    _2
$a průtoková injekční analýza $x metody $x přístrojové vybavení $7 D017022
650    _2
$a lidé $7 D006801
650    _2
$a aromatické uhlovodíky $x analýza $7 D006841
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a odběr biologického vzorku $x metody $x přístrojové vybavení $7 D013048
650    _2
$a hmotnostní spektrometrie s elektrosprejovou ionizací $x metody $x přístrojové vybavení $7 D021241
650    _2
$a volatilizace $7 D014835
700    1_
$a Dryahina, Kseniya
700    1_
$a Pehal, František $7 xx0166460
700    1_
$a Španěl, Patrik $7 xx0118200
773    0_
$t Rapid Communications in Mass Spectrometry $w MED00004050 $g Roč. 22, č. 18 (2008), s. 2844-2850 $x 0951-4198
910    __
$a ABA008 $b x $y 7
990    __
$a 20110412130949 $b ABA008
991    __
$a 20110825111136 $b ABA008
999    __
$a ok $b bmc $g 834431 $s 698933
BAS    __
$a 3
BMC    __
$a 2008 $b 22 $c 18 $d 2844-2850 $i 0951-4198 $m Rapid communications in mass spectrometry $n Rapid Commun Mass Spectrom $x MED00004050
LZP    __
$a 2011-4B/ewme

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...