• Je něco špatně v tomto záznamu ?

Cryopreserved semilunar heart valve allografts: leaflet surface damage in scanning electron microscopy

J Burkert, O Krs, J Vojacek, A Mokracek, D Slizova, J Hlubocky, P Kobylka, J Spatenka

. 2008 ; 133 (4) : 367-373.

Jazyk angličtina Země Německo

Typ dokumentu srovnávací studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc11006839

OBJECTIVE: Allograft heart valves (AHV), biological valves of human origin, offer potential advantages over conventional xenografts in terms of superior hemodynamics and, perhaps, better durability. The most important factors for long-term AHV clinical performance are the processing and cryopreservation methods. The aim of this study was to evaluate the impact of current processing protocol on valve tissue morphology, mainly to address the effect of successive processing steps on the leaflet surface structure. For the detection of fine changes in endothelial covering and underlying layers, our own modification of the scanning electron microscopy (SEM) technique was utilized. MATERIAL AND METHODS: The study was based on an investigation of 20 AHV (40 specimens). Fourteen valves came from heart-beating donors (multiorgan harvesting) when the heart could not be transplanted for any reason (donor criteria, availability of recipient and/or logistics). Six were obtained at the time of routine postmortems--non heart-beating donors (NHBD). All specimens were initially fixed in Baker's solution. Tissue samples were dissected, dried with hexamethyldisilazane (HMDS), gold-coated, studied and photographed by SEM (Tesla BS 301). In order to define the integrity of the endothelium, subendothelial layers and the quality of the surface under SEM, a special six-level score system was introduced: 1-intact endothelium, 2-confluent endothelium with structural inhomogeneity, 3-disruption of intercellular contacts, 4-separation of endothelial cells, 5-complete loss of endothelium, 6-damage of subendothelial layers). AHV samples were divided into 4 groups for comparison. One aortic AHV "fresh" control sample obtained from a heart-beating donor was evaluated without any processing and was compared with (i) tissue from AHV obtained from NHBD with warm ischemia of 12 and 48 hours, (ii) samples stored at +4 degrees C in saline for 24 h, (iii) antibiotic-treated tissue for 24 h at 37 degrees C and finally with (iv) cryopreserved valves stored in liquid nitrogen (-196 degrees C) for 6-38 months. RESULTS: Our alternative for drying samples by the HMDS method proved to be suitable for thin membranes of human semilunar valves. We were able to detect early changes in the endothelium after harvesting and denudation of the endothelial covering during preservation with and without freezing. The surface of the AHV samples revealed the typical features and score system determined endothelial cell damage. Control "fresh" sample: score 2, (i) NHBD samples with warm ischemia of 12 h: score 3-4, with warm ischemia of 48 h: score 4-5, (ii) samples stored at +4 degrees C in saline for 48 h: score 5-6, (iii) antibiotic-treated tissue for 24 h at 37 degrees C: score 5, (iv) cryopreserved valves stored in liquid nitrogen for 6-38 months: score 5-6. CONCLUSION: SEM (using HMDS drying) together with other methods may be helpful for the morphological control of processing, cryopreservation and liquid nitrogen storage of AHV. Severe AHV leaflet endothelial destruction was proven on AHV grafts. These changes arose already in the initial steps of tissue processing, just after the donor heart harvesting and then at the time of antibiotic valve graft treatment. These results are considered as the starting point for the development of a better preservation protocol.

000      
02310naa 2200421 a 4500
001      
bmc11006839
003      
CZ-PrNML
005      
20151026111350.0
008      
110406s2008 gw e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Burkert, Jan $7 xx0171077
245    10
$a Cryopreserved semilunar heart valve allografts: leaflet surface damage in scanning electron microscopy / $c J Burkert, O Krs, J Vojacek, A Mokracek, D Slizova, J Hlubocky, P Kobylka, J Spatenka
314    __
$a Transplant Center University Hospital Motol & Department of Cardiac Surgery, 2nd Medical Faculty, Charles University, Prague, Czech Republic.
520    9_
$a OBJECTIVE: Allograft heart valves (AHV), biological valves of human origin, offer potential advantages over conventional xenografts in terms of superior hemodynamics and, perhaps, better durability. The most important factors for long-term AHV clinical performance are the processing and cryopreservation methods. The aim of this study was to evaluate the impact of current processing protocol on valve tissue morphology, mainly to address the effect of successive processing steps on the leaflet surface structure. For the detection of fine changes in endothelial covering and underlying layers, our own modification of the scanning electron microscopy (SEM) technique was utilized. MATERIAL AND METHODS: The study was based on an investigation of 20 AHV (40 specimens). Fourteen valves came from heart-beating donors (multiorgan harvesting) when the heart could not be transplanted for any reason (donor criteria, availability of recipient and/or logistics). Six were obtained at the time of routine postmortems--non heart-beating donors (NHBD). All specimens were initially fixed in Baker's solution. Tissue samples were dissected, dried with hexamethyldisilazane (HMDS), gold-coated, studied and photographed by SEM (Tesla BS 301). In order to define the integrity of the endothelium, subendothelial layers and the quality of the surface under SEM, a special six-level score system was introduced: 1-intact endothelium, 2-confluent endothelium with structural inhomogeneity, 3-disruption of intercellular contacts, 4-separation of endothelial cells, 5-complete loss of endothelium, 6-damage of subendothelial layers). AHV samples were divided into 4 groups for comparison. One aortic AHV "fresh" control sample obtained from a heart-beating donor was evaluated without any processing and was compared with (i) tissue from AHV obtained from NHBD with warm ischemia of 12 and 48 hours, (ii) samples stored at +4 degrees C in saline for 24 h, (iii) antibiotic-treated tissue for 24 h at 37 degrees C and finally with (iv) cryopreserved valves stored in liquid nitrogen (-196 degrees C) for 6-38 months. RESULTS: Our alternative for drying samples by the HMDS method proved to be suitable for thin membranes of human semilunar valves. We were able to detect early changes in the endothelium after harvesting and denudation of the endothelial covering during preservation with and without freezing. The surface of the AHV samples revealed the typical features and score system determined endothelial cell damage. Control "fresh" sample: score 2, (i) NHBD samples with warm ischemia of 12 h: score 3-4, with warm ischemia of 48 h: score 4-5, (ii) samples stored at +4 degrees C in saline for 48 h: score 5-6, (iii) antibiotic-treated tissue for 24 h at 37 degrees C: score 5, (iv) cryopreserved valves stored in liquid nitrogen for 6-38 months: score 5-6. CONCLUSION: SEM (using HMDS drying) together with other methods may be helpful for the morphological control of processing, cryopreservation and liquid nitrogen storage of AHV. Severe AHV leaflet endothelial destruction was proven on AHV grafts. These changes arose already in the initial steps of tissue processing, just after the donor heart harvesting and then at the time of antibiotic valve graft treatment. These results are considered as the starting point for the development of a better preservation protocol.
650    _2
$a bazální membrána $x patologie $7 D001485
650    _2
$a kryoprezervace $7 D015925
650    _2
$a cévní endotel $x patologie $7 D004730
650    _2
$a srdeční chlopně $x patologie $x transplantace $7 D006351
650    _2
$a lidé $7 D006801
650    _2
$a mikroskopie elektronová rastrovací $7 D008855
650    _2
$a povrchové vlastnosti $7 D013499
650    _2
$a odběr tkání a orgánů $7 D020858
650    _2
$a homologní transplantace $7 D014184
650    _2
$a teplá ischemie $7 D052096
650    _2
$a financování organizované $7 D005381
655    _2
$a srovnávací studie $7 D003160
700    1_
$a Krs, Otakar $7 xx0104932
700    1_
$a Vojáček, Jan, $d 1947- $7 jn20000402578
700    1_
$a Mokráček, Aleš, $d 1966- $7 xx0094268
700    1_
$a Slížová, Dáša, $d 1953- $7 xx0019026
700    1_
$a Hlubocký, Jaroslav $7 xx0074061
700    1_
$a Kobylka, Petr, $d 1949- $7 xx0060254
700    1_
$a Špatenka, Jaroslav, $d 1945- $7 jn20000402869
773    0_
$t Zentralblatt für Chirurgie $w MED00010838 $g Roč. 133, č. 4 (2008), s. 367-373 $x 0044-409X
910    __
$a ABA008 $b A 354 $y 7 $z 0
990    __
$a 20110412131322 $b ABA008
991    __
$a 20151026111352 $b ABA008
999    __
$a ok $b bmc $g 834456 $s 698958
BAS    __
$a 3
BMC    __
$a 2008 $b 133 $c 4 $d 367-373 $i 0044-409X $m Zentralblatt für Chirurgie $n Zent.bl. Chir $x MED00010838
LZP    __
$a 2011-4B/ewme

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...