Divergent flow isoelectric focusing: fast and efficient method for protein sample preparation for mass spectrometry
K. Mazanec, J Bobáľová, K. Šlais
Jazyk angličtina Země Německo
NLK
Medline Complete (EBSCOhost)
od 2003-01-01 do Před 1 rokem
- MeSH
- časové faktory MeSH
- design vybavení MeSH
- elektrody MeSH
- financování organizované MeSH
- isoelektrická fokusace metody přístrojové vybavení MeSH
- koncentrace vodíkových iontů MeSH
- metody pro přípravu analytických vzorků metody MeSH
- molekulová hmotnost MeSH
- proteiny analýza MeSH
- proteomika MeSH
- reprodukovatelnost výsledků MeSH
- senzitivita a specificita MeSH
- spektrometrie hmotnostní - ionizace laserem za účasti matrice metody přístrojové vybavení MeSH
A study of complex protein mixtures obtained from biological samples by MS demands proper purification and separation technique. The method of divergent flow isoelectric focusing (DF IEF) promises improvement of sample preparation in proteomic studies. DF IEF was carried out in a separation channel with increasing width. The channel was cut out from a polyester nonwoven web. DC voltage (800 V) was brought to two pairs of electrodes situated on the channel sides. Amphoteric compounds, including proteins, drift through the channel carried by flow (18-25 ml/h) in streamlines given by their isoelectric points. The pH gradient (3-10) and its stability during analysis have been monitored with colored low-molecular mass pI markers. Separated fractions were collected in ten microvials and further analyzed by MS. The suggested method was used for separation and purification of crude protein extract from barley grain, malt, and beer. Collected fractions of separated proteins were characterized by MALDI-MS. Desalting during IEF enhanced significantly the quality of mass spectra. It also simplified monitoring of post-translational modifications and protein changes occurring during malting and brewing. Results have shown the real potential of the suggested DF IEF device lay-out as an efficient preparative tool for separation and purification of complex protein mixtures for further analyses.
- 000
- 03071naa 2200397 a 4500
- 001
- bmc11009599
- 003
- CZ-PrNML
- 005
- 20250819135527.0
- 008
- 110510s2009 gw e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Mazanec, Karel $7 _AN050243
- 245 10
- $a Divergent flow isoelectric focusing: fast and efficient method for protein sample preparation for mass spectrometry / $c K. Mazanec, J Bobáľová, K. Šlais
- 314 __
- $a Institute of Analytical Chemistry of the ASCR, v. v. i., Veveri 97, 602 00, Brno, Czech Republic. mazanec@iach.cz
- 520 9_
- $a A study of complex protein mixtures obtained from biological samples by MS demands proper purification and separation technique. The method of divergent flow isoelectric focusing (DF IEF) promises improvement of sample preparation in proteomic studies. DF IEF was carried out in a separation channel with increasing width. The channel was cut out from a polyester nonwoven web. DC voltage (800 V) was brought to two pairs of electrodes situated on the channel sides. Amphoteric compounds, including proteins, drift through the channel carried by flow (18-25 ml/h) in streamlines given by their isoelectric points. The pH gradient (3-10) and its stability during analysis have been monitored with colored low-molecular mass pI markers. Separated fractions were collected in ten microvials and further analyzed by MS. The suggested method was used for separation and purification of crude protein extract from barley grain, malt, and beer. Collected fractions of separated proteins were characterized by MALDI-MS. Desalting during IEF enhanced significantly the quality of mass spectra. It also simplified monitoring of post-translational modifications and protein changes occurring during malting and brewing. Results have shown the real potential of the suggested DF IEF device lay-out as an efficient preparative tool for separation and purification of complex protein mixtures for further analyses.
- 590 __
- $a bohemika - dle Pubmed
- 650 _2
- $a metody pro přípravu analytických vzorků $x metody $7 D053000
- 650 _2
- $a elektrody $7 D004566
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a koncentrace vodíkových iontů $7 D006863
- 650 _2
- $a isoelektrická fokusace $x metody $x přístrojové vybavení $7 D007525
- 650 _2
- $a molekulová hmotnost $7 D008970
- 650 _2
- $a proteiny $x analýza $7 D011506
- 650 _2
- $a proteomika $7 D040901
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a spektrometrie hmotnostní - ionizace laserem za účasti matrice $x metody $x přístrojové vybavení $7 D019032
- 650 _2
- $a časové faktory $7 D013997
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Bobáľová, Janette $7 xx0334836
- 700 1_
- $a Šlais, Karel $7 xx0071057
- 773 0_
- $t Analytical and bioanalytical chemistry $w MED00006638 $g Roč. 393, č. 6-7 (2009), s. 1769-1778
- 910 __
- $a ABA008 $b x $y 2 $z 0
- 990 __
- $a 20110513110539 $b ABA008
- 991 __
- $a 20250819135510 $b ABA008
- 999 __
- $a ok $b bmc $g 839104 $s 702990
- BAS __
- $a 3
- BMC __
- $a 2009 $b 393 $c 6-7 $d 1769-1778 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- LZP __
- $a 2011-2B09/jvme