Mechanical properties of mitral allografts are not reasonably influenced by cryopreservation in sheep model
J. Hlubocký, A. Mokráček, V. Nováček, J. Vojáček, J. Burkert, P. Kochová, J. Klepáček, J. Pepper, J. Špatenka
Jazyk angličtina Země Česko
NLK
Directory of Open Access Journals
od 1991
Free Medical Journals
od 1998
ProQuest Central
od 2005-01-01
Medline Complete (EBSCOhost)
od 2006-01-01
Nursing & Allied Health Database (ProQuest)
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1998
- MeSH
- kryoprezervace MeSH
- mechanický stres MeSH
- mitrální chlopeň MeSH
- modely u zvířat MeSH
- ovce MeSH
- povrchové vlastnosti MeSH
- srdeční chlopně umělé MeSH
- trikuspidální chlopeň chirurgie MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
A mitral allograft is used exceptionally in the mitral, as well as in the tricuspid position, mostly as an experimental surgical procedure. The authors decided to evaluate the possibility of inserting a cryopreserved mitral allograft into the tricuspid position in a sheep experimental model. Within the framework of this experimental project the mechanical properties of the cryopreserved mitral allograft were tested. A novel methodology studying the functional unit composed of mitral annulus, leaflet, chordae tendinaea, and papillary muscle is presented. A five-parameter Maxwell model was applied to characterize the viscoelastic behavior of sheep mitral valves. A control group of 39 fresh mitral specimens and a test group of 13 cryopreserved mitral allografts from tissue bank were tested. The testing protocol consisted of six loading cycles with 1 mm elongation every 5 min. There was no significant difference in the mean values of the determined parameters (p>0.05) which confirms the main hypothesis that cryopreservation does not influence significantly material parameters characterizing the tissue mechanics. Slight discrepancy is observed in variances of viscous parameters suggesting that the values of the test group may be spread over larger interval due to the treatment.
Citace poskytuje Crossref.org
Lit.: 19
- 000
- 00000naa 2200000 a 4500
- 001
- bmc11032044
- 003
- CZ-PrNML
- 005
- 20120328092952.0
- 008
- 110912s2011 xr e eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.932074 $2 doi
- 035 __
- $a (PubMed)21401294
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Hlubocký, Jaroslav $7 xx0074061
- 245 10
- $a Mechanical properties of mitral allografts are not reasonably influenced by cryopreservation in sheep model / $c J. Hlubocký, A. Mokráček, V. Nováček, J. Vojáček, J. Burkert, P. Kochová, J. Klepáček, J. Pepper, J. Špatenka
- 314 __
- $a Transplant Center University Hospital Motol, Prague, Czech Republic. vit.novacek@gmail.com.
- 504 __
- $a Lit.: 19
- 520 9_
- $a A mitral allograft is used exceptionally in the mitral, as well as in the tricuspid position, mostly as an experimental surgical procedure. The authors decided to evaluate the possibility of inserting a cryopreserved mitral allograft into the tricuspid position in a sheep experimental model. Within the framework of this experimental project the mechanical properties of the cryopreserved mitral allograft were tested. A novel methodology studying the functional unit composed of mitral annulus, leaflet, chordae tendinaea, and papillary muscle is presented. A five-parameter Maxwell model was applied to characterize the viscoelastic behavior of sheep mitral valves. A control group of 39 fresh mitral specimens and a test group of 13 cryopreserved mitral allografts from tissue bank were tested. The testing protocol consisted of six loading cycles with 1 mm elongation every 5 min. There was no significant difference in the mean values of the determined parameters (p>0.05) which confirms the main hypothesis that cryopreservation does not influence significantly material parameters characterizing the tissue mechanics. Slight discrepancy is observed in variances of viscous parameters suggesting that the values of the test group may be spread over larger interval due to the treatment.
- 650 02
- $a zvířata $7 D000818
- 650 02
- $a kryoprezervace $7 D015925
- 650 02
- $a srdeční chlopně umělé $7 D006350
- 650 02
- $a mitrální chlopeň $7 D008943
- 650 02
- $a modely u zvířat $7 D023421
- 650 02
- $a ovce $7 D012756
- 650 02
- $a mechanický stres $7 D013314
- 650 02
- $a povrchové vlastnosti $7 D013499
- 650 02
- $a trikuspidální chlopeň $x chirurgie $7 D014261
- 700 1_
- $a Mokráček, Aleš, $d 1966- $7 xx0094268
- 700 1_
- $a Nováček, Vít. $7 xx0244659
- 700 1_
- $a Vojáček, Jan, $d 1967- $7 xx0080226
- 700 1_
- $a Burkert, Jan $7 xx0171077
- 700 1_
- $a Kochová, Petra. $7 _AN047718
- 700 1_
- $a Klepáček, Jan. $7 _AN062876
- 700 1_
- $a Pepper, J.
- 700 1_
- $a Špatenka, Jaroslav, $d 1945- $7 jn20000402869
- 773 0_
- $w MED00003824 $t Physiological research $g Roč. 60, č. 3 (2011), s. 475-482 $x 0862-8408
- 856 41
- $u http://www.biomed.cas.cz/physiolres/pdf/60/60_475.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 4120 $c 266 $y 2
- 990 __
- $a 20110912095705 $b ABA008
- 991 __
- $a 20120328092935 $b ABA008
- 999 __
- $a ok $b bmc $g 877124 $s 742121
- BAS __
- $a 3
- BMC __
- $a 2011 $b 60 $c 3 $d 475-482 $m Physiological research $x MED00003824
- LZP __
- $a 2011-16/mkme