-
Je něco špatně v tomto záznamu ?
A convenient purification and preconcentration of peptides with alpha-cyano-4-hydroxycinnamic acid matrix crystals in a pipette tip for matrix-assisted laser desorption/ionization mass spectrometry
H Rehulkova, J Chalupova, M Sebela, P Rehulka
Jazyk angličtina Země Velká Británie
Typ dokumentu práce podpořená grantem
NLK
Wiley Online Library (archiv)
od 1996-01-01 do 2012-12-31
- MeSH
- chemická frakcionace metody MeSH
- kyseliny kumarové chemie MeSH
- peptidy chemie izolace a purifikace MeSH
- soli chemie izolace a purifikace MeSH
- spektrometrie hmotnostní - ionizace laserem za účasti matrice metody MeSH
- tandemová hmotnostní spektrometrie metody MeSH
- Publikační typ
- práce podpořená grantem MeSH
Peptide samples derived from enzymatic in-gel digestion of proteins resolved by gel electrophoresis often contain high amount of salts originating from reaction and separation buffers. Different methods are used for desalting prior to matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS), e.g. reversed-phase pipette tip purification, on-target washing, adding co-matrices, etc. As a suitable matrix for MALDI MS of peptides, alpha-cyano-4-hydroxycinnamic acid (CHCA) is frequently used. Crystalline CHCA shows the ability to bind peptides on its surface and because it is almost insoluble in acidic water solutions, the on-target washing of peptide samples can significantly improve MALDI MS signals. Although the common on-target washing represents a simple, cheap and fast procedure, only a small portion of the available peptide solution is efficiently used for the subsequent MS analysis. The present approach is a combination of the on-target washing principle carried out in a narrow-end pipette tip (e.g. GELoader tip) and preconcentration of peptides from acidified solution by passing it through small CHCA crystals captured inside the tip on a glass microfiber frit. The results of MALDI MS analysis using CHCA-tip peptide preconcentration are comparable with the use of homemade POROS R2 pipette tip microcolumns. Advantages and limitations of this approach are discussed. Copyright 2009 John Wiley & Sons, Ltd.
- 000
- 03008naa a2200349 a 4500
- 001
- bmc12008665
- 003
- CZ-PrNML
- 005
- 20121123115247.0
- 008
- 120316s2010 xxk eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $d ABA008
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Rehulkova H $u Faculty of Military Health Sciences, Institute of Molecular Pathology, University of Defence, Trebesska 1575, CZ-50001 Hradec Kralove, Czech Republic.
- 245 12
- $a A convenient purification and preconcentration of peptides with alpha-cyano-4-hydroxycinnamic acid matrix crystals in a pipette tip for matrix-assisted laser desorption/ionization mass spectrometry / $c H Rehulkova, J Chalupova, M Sebela, P Rehulka
- 520 9_
- $a Peptide samples derived from enzymatic in-gel digestion of proteins resolved by gel electrophoresis often contain high amount of salts originating from reaction and separation buffers. Different methods are used for desalting prior to matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS), e.g. reversed-phase pipette tip purification, on-target washing, adding co-matrices, etc. As a suitable matrix for MALDI MS of peptides, alpha-cyano-4-hydroxycinnamic acid (CHCA) is frequently used. Crystalline CHCA shows the ability to bind peptides on its surface and because it is almost insoluble in acidic water solutions, the on-target washing of peptide samples can significantly improve MALDI MS signals. Although the common on-target washing represents a simple, cheap and fast procedure, only a small portion of the available peptide solution is efficiently used for the subsequent MS analysis. The present approach is a combination of the on-target washing principle carried out in a narrow-end pipette tip (e.g. GELoader tip) and preconcentration of peptides from acidified solution by passing it through small CHCA crystals captured inside the tip on a glass microfiber frit. The results of MALDI MS analysis using CHCA-tip peptide preconcentration are comparable with the use of homemade POROS R2 pipette tip microcolumns. Advantages and limitations of this approach are discussed. Copyright 2009 John Wiley & Sons, Ltd.
- 590 __
- $a bohemika - dle Pubmed
- 650 02
- $a chemická frakcionace $x metody $7 D005591
- 650 02
- $a kyseliny kumarové $x chemie $7 D003373
- 650 02
- $a peptidy $x chemie $x izolace a purifikace $7 D010455
- 650 02
- $a soli $x chemie $x izolace a purifikace $7 D012492
- 650 02
- $a spektrometrie hmotnostní - ionizace laserem za účasti matrice $x metody $7 D019032
- 650 02
- $a tandemová hmotnostní spektrometrie $x metody $7 D053719
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Chalupova J
- 700 1_
- $a Sebela M
- 700 1_
- $a Rehulka P
- 773 0_
- $t Journal of Mass Spectrometry $p J Mass Spectrom $g Roč. 45, č. 1 (2010), s. 104-111 $w MED00002779 $x 0020-8868
- 773 0_
- $p J Mass Spectrom $g 45(1):104-11, 2010 Jan
- 910 __
- $a ABA008 $b x $y 4
- 990 __
- $a 20120319124613 $b ABA008
- 991 __
- $a 20121123115310 $b ABA008
- 999 __
- $a ok $b bmc $g 902007 $s 765560
- BAS __
- $a 3
- BMC __
- $a 2010 $b 45 $c 1 $d 104-111 $m Journal of mass spectrometry $x MED00002779
- LZP __
- $a 2012-1Q10/