• Je něco špatně v tomto záznamu ?

Serum level of sCD163, a soluble receptor for hemoglobin, is influenced by cardiac surgery

M. Koláčková, V. Lonský, M. Trojáčková Kudlová, J. Manďák, P. Kuneš, V. Svitek, K. Jankovičová, D. Vlaskova, C. Andrýs, J. Krejsek

. 2009 ; 24 (4) : 263-269.

Jazyk angličtina Země Velká Británie

Perzistentní odkaz   https://www.medvik.cz/link/bmc12009133

Grantová podpora
NR9090 MZ0 CEP - Centrální evidence projektů

Digitální knihovna NLK
Plný text - Článek
Zdroj

E-zdroje Online

NLK ProQuest Central od 1997-01-01 do 2015-11-30
SAGE Publications Journals od 1999-01-01 do 2015-12-31
CINAHL Plus with Full Text (EBSCOhost) od 1997-01-01 do 2016-05-31
Medline Complete (EBSCOhost) od 1997-01-01 do 2016-05-31
Nursing & Allied Health Database (ProQuest) od 1997-01-01 do 2015-11-30
Health & Medicine (ProQuest) od 1997-01-01 do 2015-11-30

BACKGROUND: The scavenger receptor for complexes hemoglobin-haptoglobin (CD163), which is expressed on monocytes/ macrophages, is shed to the body fluids in a soluble form (sCD163). OBJECTIVES: To evaluate the dynamics of sCD163 in the blood of patients undergoing cardiac surgery. PATIENTS AND METHODS: Sixty-one adult patients who underwent coronary artery bypass grafting (CABG) were enrolled in the study. They were assigned to undergo CABG using either cardiopulmonary bypass (CPB), "on-pump", (22 patients), modified CPB, mini "on-pump", (17 patients) or without CPB, "off-pump", (22 patients) surgery. Serum levels of sCD163 in venous blood samples taken before and after surgery, and during an early postoperative period, were evaluated by Macro 163(TM) diagnostic kit (IQ Products, Groningen, NL). RESULTS: Compared to the preoperative levels ("on-pump"; 344 ng/mL, "off-pump"; 314.5 ng/mL, mini-invasive "on-pump"; 336.5 ng/mL) serum levels were elevated at the finish of surgery, reaching maximum at the 1(st) postoperative day ("onpump"; 658 ng/mL; p<0.05, "off-pump"; 810.5 ng/mL; p<0.01; mini-invasive "on-pump"; 663 ng/mL; non-significant).No significant differences regarding the serum levels of sCD163 between different surgical approaches were found. CONCLUSION: Serum level of sCD163 scavenger molecule for hemoglobin is elevated at the end of surgery and at the 1(st) postoperative day, being little influenced by cardiopulmonary bypass.

000      
03320naa a2200529 a 4500
001      
bmc12009133
003      
CZ-PrNML
005      
20140409144728.0
008      
120319s2009 xxk eng||
009      
AR
040    __
$d ABA008 $a ABA008 $b cze
041    0_
$a eng
044    __
$a xxk
100    1_
$a Koláčková, Martina. $7 _BN000863 $u Department of Clinical Immunology and Allergy, Charles University in Prague, Faculty of Medicine and University Hospital in Hradec Kralove, Hradec Kralove
245    10
$a Serum level of sCD163, a soluble receptor for hemoglobin, is influenced by cardiac surgery / $c M. Koláčková, V. Lonský, M. Trojáčková Kudlová, J. Manďák, P. Kuneš, V. Svitek, K. Jankovičová, D. Vlaskova, C. Andrýs, J. Krejsek
520    9_
$a BACKGROUND: The scavenger receptor for complexes hemoglobin-haptoglobin (CD163), which is expressed on monocytes/ macrophages, is shed to the body fluids in a soluble form (sCD163). OBJECTIVES: To evaluate the dynamics of sCD163 in the blood of patients undergoing cardiac surgery. PATIENTS AND METHODS: Sixty-one adult patients who underwent coronary artery bypass grafting (CABG) were enrolled in the study. They were assigned to undergo CABG using either cardiopulmonary bypass (CPB), "on-pump", (22 patients), modified CPB, mini "on-pump", (17 patients) or without CPB, "off-pump", (22 patients) surgery. Serum levels of sCD163 in venous blood samples taken before and after surgery, and during an early postoperative period, were evaluated by Macro 163(TM) diagnostic kit (IQ Products, Groningen, NL). RESULTS: Compared to the preoperative levels ("on-pump"; 344 ng/mL, "off-pump"; 314.5 ng/mL, mini-invasive "on-pump"; 336.5 ng/mL) serum levels were elevated at the finish of surgery, reaching maximum at the 1(st) postoperative day ("onpump"; 658 ng/mL; p<0.05, "off-pump"; 810.5 ng/mL; p<0.01; mini-invasive "on-pump"; 663 ng/mL; non-significant).No significant differences regarding the serum levels of sCD163 between different surgical approaches were found. CONCLUSION: Serum level of sCD163 scavenger molecule for hemoglobin is elevated at the end of surgery and at the 1(st) postoperative day, being little influenced by cardiopulmonary bypass.
590    __
$a bohemika - dle Pubmed
650    02
$a senioři $7 D000368
650    02
$a CD antigeny $x krev $7 D015703
650    02
$a antigeny diferenciační myelomonocytární $x krev $7 D015214
650    02
$a kardiopulmonální bypass $x škodlivé účinky $7 D002315
650    02
$a koronární bypass $x škodlivé účinky $7 D001026
650    02
$a ženské pohlaví $7 D005260
650    02
$a haptoglobiny $x metabolismus $7 D006242
650    02
$a hemoglobiny $x metabolismus $7 D006454
650    02
$a lidé $7 D006801
650    02
$a zánět $x etiologie $x krev $7 D007249
650    02
$a mužské pohlaví $7 D008297
650    02
$a lidé středního věku $7 D008875
650    02
$a receptory buněčného povrchu $x krev $7 D011956
700    1_
$a Lonský, Vladimír, $d 1953- $7 jo2004232723
700    1_
$a Trojáčková Kudlová, Manuela $7 xx0083626
700    1_
$a Manďák, Jiří, $d 1958- $7 mzk2006337422
700    1_
$a Kuneš, Pavel $7 xx0082993
700    1_
$a Svitek, Vladimír $7 xx0145006
700    1_
$a Jankovičová, Karolína $7 stk2008428938
700    1_
$a Vlášková, Dana
700    1_
$a Andrýs, Ctirad, $d 1962- $7 mzk2008430528
700    1_
$a Krejsek, Jan, $d 1958- $7 nlk19990073429
773    0_
$t Perfusion $p Perfusion $g Roč. 24, č. 4 (2009), s. 263-269 $x def $w MED00003752
773    0_
$p Perfusion $g 24(4):263-9, 2009 Jul
910    __
$a ABA008 $b x $y 4 $z 0
990    __
$a 20120319150909 $b ABA008
991    __
$a 20140409144816 $b ABA008
999    __
$a ok $b bmc $g 902357 $s 766039
BAS    __
$a 3
BMC    __
$a 2009 $b 24 $c 4 $d 263-269 $i def $m Perfusion $x MED00003752
GRA    __
$a NR9090 $p MZ0
LZP    __
$a 2012-1Q10/

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...