Detail
Článek
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Topically-used gentamicin attached to nanofibre mdoctm compared with garamycin schwamm® in an acute wound infection model. an experimental study

Petr Lochman, Jiri Paral, Dusan Simkovic, Jaromir Koci

. 2012 ; 81 (1) : 9-15.

Jazyk angličtina Země Česko

Typ dokumentu srovnávací studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc12012292

The aim of this study was to examine the effect of topically-used gentamicin attached to a biodegradable carrier, formed by micro-dispersed oxidised cellulose (MDOC) in nanofibre form, in acute wound infection treatment and to compare it with Garamycin Schwamm®. Twelve domestic swines were used in a model of a full-thickness infected dermal wound. The effectiveness of both materials in wound infections caused by Staphylococcus aureus, Pseudomonas aeruginosa and Escherichia coli was tested. The effectiveness of both gentamicin with MDOC and Garamycin Schwamm® was comparable in Pseudomonas aeruginosa and Escherichia coli infections according to microbiological cultures findings. With Staphylococcus aureus infections there was a higher percent of negative cultures when MDOC with gentamicin was administered, but without statistical significance (p=0.069). When macroscopically assesed, 100 % of infected wounds treated by gentamicin attached to MDOC were without signs of local infection compared to only 16.7 % when Garamycin Schwamm® was used and this was statistically significant (p<0.01). For statistical analysis we used a Fisher´s exact test. When combined with a nanofibre MDOC carrier, topically-used gentamicin seems to be rendered more for treatment of full-thickness skin infections. The resulting good haemostatic effect of MDOC was observed.

Obsahuje 2 tabulky

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc12012292
003      
CZ-PrNML
005      
20120627103734.0
007      
ta
008      
120411s2012 xr fo f 000 0eng||
009      
AR
024    7_
$a 10.31482/mmsl.2012.002 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Lochman, Petr $7 xx0092570 $u Department of Field Surgery, Faculty of Military Health Sciences, University of Defence, Hradec Králové; Department of Surgery, University Hospital, Hradec Králové
245    10
$a Topically-used gentamicin attached to nanofibre mdoctm compared with garamycin schwamm® in an acute wound infection model. an experimental study / $c Petr Lochman, Jiri Paral, Dusan Simkovic, Jaromir Koci
500    __
$a Obsahuje 2 tabulky
504    __
$a Literatura $b 26
520    9_
$a The aim of this study was to examine the effect of topically-used gentamicin attached to a biodegradable carrier, formed by micro-dispersed oxidised cellulose (MDOC) in nanofibre form, in acute wound infection treatment and to compare it with Garamycin Schwamm®. Twelve domestic swines were used in a model of a full-thickness infected dermal wound. The effectiveness of both materials in wound infections caused by Staphylococcus aureus, Pseudomonas aeruginosa and Escherichia coli was tested. The effectiveness of both gentamicin with MDOC and Garamycin Schwamm® was comparable in Pseudomonas aeruginosa and Escherichia coli infections according to microbiological cultures findings. With Staphylococcus aureus infections there was a higher percent of negative cultures when MDOC with gentamicin was administered, but without statistical significance (p=0.069). When macroscopically assesed, 100 % of infected wounds treated by gentamicin attached to MDOC were without signs of local infection compared to only 16.7 % when Garamycin Schwamm® was used and this was statistically significant (p<0.01). For statistical analysis we used a Fisher´s exact test. When combined with a nanofibre MDOC carrier, topically-used gentamicin seems to be rendered more for treatment of full-thickness skin infections. The resulting good haemostatic effect of MDOC was observed.
650    _2
$a financování organizované $7 D005381
650    _2
$a zvířata $7 D000818
650    _2
$a prasata $7 D013552
650    _2
$a modely nemocí na zvířatech $7 D004195
650    _2
$a hodnocení léčiv $x statistika a číselné údaje $7 D004341
650    _2
$a gentamiciny $x farmakologie $x terapeutické užití $7 D005839
650    _2
$a celulosa oxidovaná $x farmakologie $x terapeutické užití $7 D002483
650    _2
$a Pseudomonas aeruginosa $x účinky léků $7 D011550
650    _2
$a Escherichia coli $x účinky léků $7 D004926
650    _2
$a Staphylococcus aureus $x účinky léků $7 D013211
650    _2
$a statistika jako téma $7 D013223
650    _2
$a infekce chirurgické rány $x farmakoterapie $x mikrobiologie $7 D013530
650    _2
$a hojení ran $x účinky léků $7 D014945
650    _2
$a infekční nemoci kůže $x farmakoterapie $x mikrobiologie $7 D012874
650    _2
$a kultivační techniky $7 D046508
650    _2
$a aplikace lokální $7 D000287
655    _2
$a srovnávací studie $7 D003160
700    1_
$a Páral, Jiří, $d 1963- $7 mzk2008469111 $u Department of Field Surgery, Faculty of Military Health Sciences, University of Defence, Hradec Králové; Department of Surgery, University Hospital, Hradec Králové
700    1_
$a Šimkovič, Dušan, $d 1946- $7 xx0127143 $u Department of Surgery, University Hospital, Hradec Králové
700    1_
$a Kočí, Jaromír, $d 1975- $7 xx0103746 $u Department of Emergency Medicine, University Hospital, Hradec Králové
773    0_
$t Vojenské zdravotnické listy $x 0372-7025 $g Roč. 81, č. 1 (2012), s. 9-15 $w MED00011116
910    __
$a ABA008 $b A 3 $c 1073 $y 2
990    __
$a 20120411102222 $b ABA008
991    __
$a 20120627103655 $b ABA008
999    __
$a ok $b bmc $g 905711 $s 769270
BAS    __
$a 3
BMC    __
$a 2012 $b 81 $c 1 $d 9-15 $i 0372-7025 $m Vojenské zdravotnické listy $n Vojen. zdr. listy $x MED00011116
LZP    __
$a 2012-17/dkhv

Citační ukazatele

Nahrávání dat...