Comparison of detected values Footscan - Kistler [Porovnání naměřených hodnot Footscan a Kistler]

Barbora Pánková, Petr Kubový, Ondřej Fanta, Karel Jelen

. 2011 ; 47 (2) : 208-214. (Kinanthropologica)

Language English Country Czech Republic

Commercially available devices objectifying the amount of pressure under the foot are often different in accuracy and reliability of results. The aim of this pilot study was to compare output values of plantar pressure within one step generated by the system Kistler and Footscan. Software synchronization of both devices was performed and it was found from the subsequent evaluation that the values of forces obtained from the device Footscan are lower than these obtained from the Kistler system. This linear correlation may be only used in the evaluation phase of the maximum loaded foot (peak area); in the phase of lightening foot from the ground the system Footscan is burdened with a significant error of measurement, probably due to nonlinearity in the mechanical properties of the surface of the measuring plate.

Porovnání naměřených hodnot Footscan a Kistler

Obsahuje 3 tabulky

Bibliography, etc.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc12019086
003      
CZ-PrNML
005      
20121030160023.0
007      
ta
008      
120622s2011 xr do f 000 0eng||
009      
AR
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng $b cze
044    __
$a xr
100    1_
$a Pánková, Barbora. $7 _AN064215 $u Department of Anatomy and Biomechanics, Faculty of Physical Education and Sport, Charles University, Prague
245    10
$a Comparison of detected values Footscan - Kistler / $c Barbora Pánková, Petr Kubový, Ondřej Fanta, Karel Jelen
246    31
$a Porovnání naměřených hodnot Footscan a Kistler
500    __
$a Obsahuje 3 tabulky
504    __
$a Literatura $b 5
520    9_
$a Commercially available devices objectifying the amount of pressure under the foot are often different in accuracy and reliability of results. The aim of this pilot study was to compare output values of plantar pressure within one step generated by the system Kistler and Footscan. Software synchronization of both devices was performed and it was found from the subsequent evaluation that the values of forces obtained from the device Footscan are lower than these obtained from the Kistler system. This linear correlation may be only used in the evaluation phase of the maximum loaded foot (peak area); in the phase of lightening foot from the ground the system Footscan is burdened with a significant error of measurement, probably due to nonlinearity in the mechanical properties of the surface of the measuring plate.
650    _2
$a noha (od hlezna dolů) $x fyziologie $x patofyziologie $x patologie $7 D005528
650    _2
$a antropometrie $x metody $x přístrojové vybavení $7 D000886
650    _2
$a tělesné váhy a míry $x metody $x využití $7 D001837
650    _2
$a tělesná hmotnost $7 D001835
650    _2
$a tlak $7 D011312
650    _2
$a biomechanika $7 D001696
650    _2
$a mechanické jevy $7 D055595
650    _2
$a kalibrace $7 D002138
650    _2
$a statistika jako téma $7 D013223
650    _2
$a lidé $7 D006801
650    _2
$a pilotní projekty $7 D010865
650    _2
$a financování organizované $7 D005381
653    00
$a synchronizace měření
653    00
$a porovnání výstupů
700    1_
$a Kubový, Petr $7 xx0105133 $u Department of Anatomy and Biomechanics, Faculty of Physical Education and Sport, Charles University, Prague
700    1_
$a Fanta, Ondřej. $7 _AN068224 $u Department of Anatomy and Biomechanics, Faculty of Physical Education and Sport, Charles University, Prague
700    1_
$a Jelen, Karel $7 jx20071213036 $u Department of Anatomy and Biomechanics, Faculty of Physical Education and Sport, Charles University, Prague
773    0_
$t Acta Universitatis Carolinae. Kinanthropologica $x 1212-1428 $g Roč. 47, č. 2 (2011), s. 208-214 $w MED00150734
856    41
$u https://karolinum.cz/data/clanek/764/Kinan_2_2011_20_pankova.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 1212 $c 865 $y 2
990    __
$a 20120621062151 $b ABA008
991    __
$a 20121030160026 $b ABA008
999    __
$a ok $b bmc $g 913119 $s 776307
BAS    __
$a 3
BMC    __
$a 2011 $b 47 $c 2 $d 208-214 $i 1212-1428 $m Acta Universitatis Carolinae. Kinanthropologica $n Acta Univ. Carol., Kinanthropologica $o Kinanthropologica $x MED00150734
LZP    __
$a 2012-33/ipal

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...