Method validation for the determination of propellant components by Soxhlet extraction and gas chromatography/mass spectrometry
O. Fryš, P. Bajerová, A. Eisner, M. Mudruňková, K. Ventura,
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články, práce podpořená grantem, validační studie
PubMed
21793207
DOI
10.1002/jssc.201100279
Knihovny.cz E-zdroje
- MeSH
- aminy analýza MeSH
- chemická frakcionace metody MeSH
- dusíkaté sloučeniny analýza MeSH
- estery analýza MeSH
- plynová chromatografie s hmotnostně spektrometrickou detekcí MeSH
- reprodukovatelnost výsledků MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- validační studie MeSH
A fast, sensitive, and accurate GC/MS method for the quantification of aliphatic nitroesters (ethylene glycol dinitrate, nitroglycerin, and triethylene glycol dinitrate) and aromatic amines (diphenylamine, 2-nitrodiphenylamine, and triphenylamine) in propellants was developed and validated. This method comprises a Soxhlet extraction step with dichloromethane, followed by separation on a capillary column MDN-5. Ionization of the analytes is carried out using electron ionization. The limit of quantification of the method was 1% w/w for aliphatic nitroesters and 0.1% w/w for aromatic amines (diphenylamine and triphenylamine). Values of repeatability and reproducibility for analyzed compounds were smaller than values of the maximum allowed tolerances of the Horwitz-equation RSD(max) and 2/3 RSD(max). Values of accuracy for selected compounds were below the acceptable threshold of 15% for all tested levels in the range of calibration curve excepting the lowest concentration of calibration curve for nitroglycerin and aromatic amines. During the validation of method, temperature instability in injection port of gas chromatograph and column was observed for 2-nitrodiphenylamine. Hence, it follows worse results of accuracy and linearity and 2-nitrodiphenylamine was not validated successfully.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12022436
- 003
- CZ-PrNML
- 005
- 20170410102243.0
- 007
- ta
- 008
- 120806s2011 gw f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1002/jssc.201100279 $2 doi
- 035 __
- $a (PubMed)21793207
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Fryš, Ondřej $u University of Pardubice, Faculty of Chemical Technology, Department of Analytical Chemistry, Pardubice, Czech Republic.
- 245 10
- $a Method validation for the determination of propellant components by Soxhlet extraction and gas chromatography/mass spectrometry / $c O. Fryš, P. Bajerová, A. Eisner, M. Mudruňková, K. Ventura,
- 520 9_
- $a A fast, sensitive, and accurate GC/MS method for the quantification of aliphatic nitroesters (ethylene glycol dinitrate, nitroglycerin, and triethylene glycol dinitrate) and aromatic amines (diphenylamine, 2-nitrodiphenylamine, and triphenylamine) in propellants was developed and validated. This method comprises a Soxhlet extraction step with dichloromethane, followed by separation on a capillary column MDN-5. Ionization of the analytes is carried out using electron ionization. The limit of quantification of the method was 1% w/w for aliphatic nitroesters and 0.1% w/w for aromatic amines (diphenylamine and triphenylamine). Values of repeatability and reproducibility for analyzed compounds were smaller than values of the maximum allowed tolerances of the Horwitz-equation RSD(max) and 2/3 RSD(max). Values of accuracy for selected compounds were below the acceptable threshold of 15% for all tested levels in the range of calibration curve excepting the lowest concentration of calibration curve for nitroglycerin and aromatic amines. During the validation of method, temperature instability in injection port of gas chromatograph and column was observed for 2-nitrodiphenylamine. Hence, it follows worse results of accuracy and linearity and 2-nitrodiphenylamine was not validated successfully.
- 650 _2
- $a aminy $x analýza $7 D000588
- 650 _2
- $a chemická frakcionace $x metody $7 D005591
- 650 _2
- $a estery $x analýza $7 D004952
- 650 _2
- $a plynová chromatografie s hmotnostně spektrometrickou detekcí $7 D008401
- 650 _2
- $a dusíkaté sloučeniny $x analýza $7 D009574
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a validační studie $7 D023361
- 700 1_
- $a Bajerová, Petra
- 700 1_
- $a Eisner, Aleš
- 700 1_
- $a Mudruňková, Martina
- 700 1_
- $a Ventura, Karel
- 773 0_
- $w MED00006463 $t Journal of separation science $x 1615-9314 $g Roč. 34, č. 18 (2011), s. 2405-2410
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21793207 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120806 $b ABA008
- 991 __
- $a 20170410102540 $b ABA008
- 999 __
- $a ok $b bmc $g 944349 $s 779733
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 34 $c 18 $d 2405-2410 $e 20110727 $i 1615-9314 $m Journal of separation science $n J Sep Sci $x MED00006463
- LZP __
- $a Pubmed-20120806/12/01