Novel biodegradable polydioxanone stents in a rabbit airway model

L. Novotny, M. Crha, P. Rauser, A. Hep, J. Misik, A. Necas, D. Vondrys,

. 2012 ; 143 (2) : 437-444.

Jazyk angličtina Země Spojené státy americké

Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12022443

OBJECTIVE: This study was undertaken to evaluate safety and biocompatibility of a novel biodegradable polydioxanone stent in a rabbit tracheal model. Metallic and silicone stents represent standard therapeutic approaches for hollow organ stenosis, although complications have been reported repeatedly. Biodegradable stents could reduce the risks associated with this procedure while still achieving the purpose of maintaining lumen patency. METHODS: A commercially available polydioxanone suture strand with a long safety record was used to manufacture the self-expanding stents. The polydioxanone stents were then implanted bronchoscopically and under fluoroscopic guidance into the tracheas of white rabbits (N = 25). Periodic clinical examination was performed. Histopathologic examination concluded the study for the 5 experimental groups at 3, 4, 5, 10, and 15 weeks after implantation. RESULTS: There were no unexpected deaths and no stent displacements during the study. The animals remained in good condition, without stent debris expectoration. Macroscopic examination revealed that the tracheal lumen stayed open. Histologic examination showed that tracheal damage score was highest 5 weeks after stenting, including in-stent necrosis of the epithelium. Stent degradation was complete with no remnants after 10 weeks, leaving the trachea completely healed at 15 weeks after implantation. CONCLUSIONS: This animal airway model has demonstrated acceptable safety and biocompatibility of this novel biodegradable polydioxanone stent. We suggest that polydioxanone stenting be used for further clinical studies for cases in which complete stent degradation after temporary airway treatment is desirable.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12022443
003      
CZ-PrNML
005      
20230116083940.0
007      
ta
008      
120806s2012 xxu f 000 0#eng||
009      
AR
024    7_
$a 10.1016/j.jtcvs.2011.08.002 $2 doi
035    __
$a (PubMed)21885070
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Novotny, Ladislav $u Institute of Pathology and Parasitology, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic.
245    10
$a Novel biodegradable polydioxanone stents in a rabbit airway model / $c L. Novotny, M. Crha, P. Rauser, A. Hep, J. Misik, A. Necas, D. Vondrys,
520    9_
$a OBJECTIVE: This study was undertaken to evaluate safety and biocompatibility of a novel biodegradable polydioxanone stent in a rabbit tracheal model. Metallic and silicone stents represent standard therapeutic approaches for hollow organ stenosis, although complications have been reported repeatedly. Biodegradable stents could reduce the risks associated with this procedure while still achieving the purpose of maintaining lumen patency. METHODS: A commercially available polydioxanone suture strand with a long safety record was used to manufacture the self-expanding stents. The polydioxanone stents were then implanted bronchoscopically and under fluoroscopic guidance into the tracheas of white rabbits (N = 25). Periodic clinical examination was performed. Histopathologic examination concluded the study for the 5 experimental groups at 3, 4, 5, 10, and 15 weeks after implantation. RESULTS: There were no unexpected deaths and no stent displacements during the study. The animals remained in good condition, without stent debris expectoration. Macroscopic examination revealed that the tracheal lumen stayed open. Histologic examination showed that tracheal damage score was highest 5 weeks after stenting, including in-stent necrosis of the epithelium. Stent degradation was complete with no remnants after 10 weeks, leaving the trachea completely healed at 15 weeks after implantation. CONCLUSIONS: This animal airway model has demonstrated acceptable safety and biocompatibility of this novel biodegradable polydioxanone stent. We suggest that polydioxanone stenting be used for further clinical studies for cases in which complete stent degradation after temporary airway treatment is desirable.
650    _2
$a vstřebatelné implantáty $7 D020341
650    _2
$a zvířata $7 D000818
650    _2
$a bronchoskopie $x škodlivé účinky $x přístrojové vybavení $7 D001999
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a fluoroskopie $7 D005471
650    _2
$a testování materiálů $7 D008422
650    _2
$a modely u zvířat $7 D023421
650    _2
$a polydioxanon $7 D016687
650    _2
$a protézy - design $7 D011474
650    _2
$a králíci $7 D011817
650    _2
$a intervenční radiografie $x metody $7 D015641
650    _2
$a stenty $7 D015607
650    _2
$a časové faktory $7 D013997
650    _2
$a trachea $x patologie $x radiografie $x chirurgie $7 D014132
655    _2
$a hodnotící studie $7 D023362
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Crha, Michal
700    1_
$a Rauser, Petr
700    1_
$a Hep, Aleš, $d 1952-2022 $7 mzk2003169597
700    1_
$a Misik, Jan
700    1_
$a Necas, Alois
700    1_
$a Vondrys, David
773    0_
$w MED00003020 $t Journal of thoracic and cardiovascular surgery $x 1097-685X $g Roč. 143, č. 2 (2012), s. 437-444
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21885070 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m $z 0
990    __
$a 20120806 $b ABA008
991    __
$a 20230116083938 $b ABA008
999    __
$a ok $b bmc $g 944356 $s 779740
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 143 $c 2 $d 437-444 $i 1097-685X $m Journal of thoracic and cardiovascular surgery $n J Thorac Cardiovasc Surg $x MED00003020
LZP    __
$a Pubmed-20120806/12/01

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace