Novel biodegradable polydioxanone stents in a rabbit airway model
L. Novotny, M. Crha, P. Rauser, A. Hep, J. Misik, A. Necas, D. Vondrys,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem
- MeSH
- bronchoskopie škodlivé účinky přístrojové vybavení MeSH
- časové faktory MeSH
- fluoroskopie MeSH
- intervenční radiografie metody MeSH
- králíci MeSH
- modely u zvířat MeSH
- polydioxanon MeSH
- protézy - design MeSH
- stenty MeSH
- testování materiálů MeSH
- trachea patologie radiografie chirurgie MeSH
- vstřebatelné implantáty MeSH
- zvířata MeSH
- Check Tag
- králíci MeSH
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
OBJECTIVE: This study was undertaken to evaluate safety and biocompatibility of a novel biodegradable polydioxanone stent in a rabbit tracheal model. Metallic and silicone stents represent standard therapeutic approaches for hollow organ stenosis, although complications have been reported repeatedly. Biodegradable stents could reduce the risks associated with this procedure while still achieving the purpose of maintaining lumen patency. METHODS: A commercially available polydioxanone suture strand with a long safety record was used to manufacture the self-expanding stents. The polydioxanone stents were then implanted bronchoscopically and under fluoroscopic guidance into the tracheas of white rabbits (N = 25). Periodic clinical examination was performed. Histopathologic examination concluded the study for the 5 experimental groups at 3, 4, 5, 10, and 15 weeks after implantation. RESULTS: There were no unexpected deaths and no stent displacements during the study. The animals remained in good condition, without stent debris expectoration. Macroscopic examination revealed that the tracheal lumen stayed open. Histologic examination showed that tracheal damage score was highest 5 weeks after stenting, including in-stent necrosis of the epithelium. Stent degradation was complete with no remnants after 10 weeks, leaving the trachea completely healed at 15 weeks after implantation. CONCLUSIONS: This animal airway model has demonstrated acceptable safety and biocompatibility of this novel biodegradable polydioxanone stent. We suggest that polydioxanone stenting be used for further clinical studies for cases in which complete stent degradation after temporary airway treatment is desirable.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12022443
- 003
- CZ-PrNML
- 005
- 20230116083940.0
- 007
- ta
- 008
- 120806s2012 xxu f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jtcvs.2011.08.002 $2 doi
- 035 __
- $a (PubMed)21885070
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Novotny, Ladislav $u Institute of Pathology and Parasitology, University of Veterinary and Pharmaceutical Sciences Brno, Brno, Czech Republic.
- 245 10
- $a Novel biodegradable polydioxanone stents in a rabbit airway model / $c L. Novotny, M. Crha, P. Rauser, A. Hep, J. Misik, A. Necas, D. Vondrys,
- 520 9_
- $a OBJECTIVE: This study was undertaken to evaluate safety and biocompatibility of a novel biodegradable polydioxanone stent in a rabbit tracheal model. Metallic and silicone stents represent standard therapeutic approaches for hollow organ stenosis, although complications have been reported repeatedly. Biodegradable stents could reduce the risks associated with this procedure while still achieving the purpose of maintaining lumen patency. METHODS: A commercially available polydioxanone suture strand with a long safety record was used to manufacture the self-expanding stents. The polydioxanone stents were then implanted bronchoscopically and under fluoroscopic guidance into the tracheas of white rabbits (N = 25). Periodic clinical examination was performed. Histopathologic examination concluded the study for the 5 experimental groups at 3, 4, 5, 10, and 15 weeks after implantation. RESULTS: There were no unexpected deaths and no stent displacements during the study. The animals remained in good condition, without stent debris expectoration. Macroscopic examination revealed that the tracheal lumen stayed open. Histologic examination showed that tracheal damage score was highest 5 weeks after stenting, including in-stent necrosis of the epithelium. Stent degradation was complete with no remnants after 10 weeks, leaving the trachea completely healed at 15 weeks after implantation. CONCLUSIONS: This animal airway model has demonstrated acceptable safety and biocompatibility of this novel biodegradable polydioxanone stent. We suggest that polydioxanone stenting be used for further clinical studies for cases in which complete stent degradation after temporary airway treatment is desirable.
- 650 _2
- $a vstřebatelné implantáty $7 D020341
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a bronchoskopie $x škodlivé účinky $x přístrojové vybavení $7 D001999
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a fluoroskopie $7 D005471
- 650 _2
- $a testování materiálů $7 D008422
- 650 _2
- $a modely u zvířat $7 D023421
- 650 _2
- $a polydioxanon $7 D016687
- 650 _2
- $a protézy - design $7 D011474
- 650 _2
- $a králíci $7 D011817
- 650 _2
- $a intervenční radiografie $x metody $7 D015641
- 650 _2
- $a stenty $7 D015607
- 650 _2
- $a časové faktory $7 D013997
- 650 _2
- $a trachea $x patologie $x radiografie $x chirurgie $7 D014132
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Crha, Michal
- 700 1_
- $a Rauser, Petr
- 700 1_
- $a Hep, Aleš, $d 1952-2022 $7 mzk2003169597
- 700 1_
- $a Misik, Jan
- 700 1_
- $a Necas, Alois
- 700 1_
- $a Vondrys, David
- 773 0_
- $w MED00003020 $t Journal of thoracic and cardiovascular surgery $x 1097-685X $g Roč. 143, č. 2 (2012), s. 437-444
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21885070 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120806 $b ABA008
- 991 __
- $a 20230116083938 $b ABA008
- 999 __
- $a ok $b bmc $g 944356 $s 779740
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 143 $c 2 $d 437-444 $i 1097-685X $m Journal of thoracic and cardiovascular surgery $n J Thorac Cardiovasc Surg $x MED00003020
- LZP __
- $a Pubmed-20120806/12/01