Analyte transport in liquid junction nano-electrospray interface between capillary electrophoresis and mass spectrometry

K. Klepárník, M. Otevřel

. 2010 ; 31 (5) : 879-885.

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12025156

The optimization of working parameters controlling the transfer of an analyte from the separation into the spray capillary at the liquid junction interface is a complex problem. The numerical models of hydrodynamic flow, electric field strength and the consequential mass transfer provide a valuable insight into the function of the miniaturized device. The results revealed that the most important parameter is the electric field strength inside the gap between the separation and spray capillaries. In a strong electric field, the analyte leaving the separation capillary is immediately transferred into the spray capillary at its maximum concentration. Although the losses of analyte outside the interface are dominant in this case, the sprayed concentration determines the detection sensitivity. Since only a small amount of the sprayed material enters mass spectrometer, the losses at the interface do not influence the sensitivity. At low electric field strength the total amount of analytes is transferred into the spray capillary. In this case, however, the analytes enter the capillary slowly and, as a result, are significantly diluted. The electric field strength, pressure and dimensions determine the mass transfer in the interface and must be considered when the optimum conditions of an analysis are chosen. Several fold improvement in sensitivity and efficiency of the method can be expected when working under the optimum conditions.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12025156
003      
CZ-PrNML
005      
20130222225210.0
007      
ta
008      
120816s2010 gw f 000 0#eng||
009      
AR
024    7_
$a 10.1002/elps.200900544 $2 doi
035    __
$a (PubMed)20191549
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Klepárník, Karel, $d 1951- $7 xx0070778 $u Institute of Analytical Chemistry, Czech Academy of Sciences, Brno, Czech Republic. klep@iach.cz
245    10
$a Analyte transport in liquid junction nano-electrospray interface between capillary electrophoresis and mass spectrometry / $c K. Klepárník, M. Otevřel
520    9_
$a The optimization of working parameters controlling the transfer of an analyte from the separation into the spray capillary at the liquid junction interface is a complex problem. The numerical models of hydrodynamic flow, electric field strength and the consequential mass transfer provide a valuable insight into the function of the miniaturized device. The results revealed that the most important parameter is the electric field strength inside the gap between the separation and spray capillaries. In a strong electric field, the analyte leaving the separation capillary is immediately transferred into the spray capillary at its maximum concentration. Although the losses of analyte outside the interface are dominant in this case, the sprayed concentration determines the detection sensitivity. Since only a small amount of the sprayed material enters mass spectrometer, the losses at the interface do not influence the sensitivity. At low electric field strength the total amount of analytes is transferred into the spray capillary. In this case, however, the analytes enter the capillary slowly and, as a result, are significantly diluted. The electric field strength, pressure and dimensions determine the mass transfer in the interface and must be considered when the optimum conditions of an analysis are chosen. Several fold improvement in sensitivity and efficiency of the method can be expected when working under the optimum conditions.
650    _2
$a elektroforéza kapilární $x metody $7 D019075
650    _2
$a analýza metodou konečných prvků $7 D020342
650    _2
$a teoretické modely $7 D008962
650    _2
$a nanotechnologie $x metody $7 D036103
650    _2
$a hmotnostní spektrometrie s elektrosprejovou ionizací $x metody $7 D021241
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1#
$a Otevřel, Marek. $7 _AN027643
773    0_
$w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 31, č. 5 (2010), s. 879-885
856    41
$u https://pubmed.ncbi.nlm.nih.gov/20191549 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120816 $b ABA008
991    __
$a 20130222225411 $b ABA008
999    __
$a ok $b bmc $g 947198 $s 782502
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 31 $c 5 $d 879-885 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
LZP    __
$a Pubmed-20120816/10/02

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...