Preparative divergent flow IEF without carrier ampholytes for separation of complex biological samples

M. Stastna, K. Slais

. 2010 ; 31 (3) : 433-439.

Language English Country Germany

Document type Journal Article, Research Support, Non-U.S. Gov't

Efficient separation method is a crucial part of the process in which components of highly complex biological sample are identified and characterized. Based on the principles of recently newly established electrophoretic method called divergent flow IEF (DF IEF), we have tested the DF IEF instrument which is able to operate without the use of background carrier ampholytes. We have verified that during separation and focusing of sample consisting of high numbers of proteins (yeast lysate and wheat flour extract), the pH gradient of preparative DF IEF can be created by autofocusing of the sample components themselves without any addition of carrier ampholytes. In DF IEF, the proteins are separated, desalted and concentrated in one step. The fractions of yeast lysate sample, collected at the DF IEF output and subjected to gel IEF, contained the zones of proteins gradually covering the pI values from 3.7 to 8.5. In our experimental arrangement, the highest number of proteins has been found in fractions with pI values around 5.3 as detected by polyacrylamide gel IEF with CBB staining. During DF IEF, the selected protein bands have been concentrated up to 16.8-fold.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12025246
003      
CZ-PrNML
005      
20130222224713.0
007      
ta
008      
120816s2010 gw f 000 0#eng||
009      
AR
024    7_
$a 10.1002/elps.200900484 $2 doi
035    __
$a (PubMed)20119953
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Šťastná, Miroslava $7 xx0137995 $u Institute of Analytical Chemistry of the ASCR, Brno, Czech Republic. stastna@iach.cz
245    10
$a Preparative divergent flow IEF without carrier ampholytes for separation of complex biological samples / $c M. Stastna, K. Slais
520    9_
$a Efficient separation method is a crucial part of the process in which components of highly complex biological sample are identified and characterized. Based on the principles of recently newly established electrophoretic method called divergent flow IEF (DF IEF), we have tested the DF IEF instrument which is able to operate without the use of background carrier ampholytes. We have verified that during separation and focusing of sample consisting of high numbers of proteins (yeast lysate and wheat flour extract), the pH gradient of preparative DF IEF can be created by autofocusing of the sample components themselves without any addition of carrier ampholytes. In DF IEF, the proteins are separated, desalted and concentrated in one step. The fractions of yeast lysate sample, collected at the DF IEF output and subjected to gel IEF, contained the zones of proteins gradually covering the pI values from 3.7 to 8.5. In our experimental arrangement, the highest number of proteins has been found in fractions with pI values around 5.3 as detected by polyacrylamide gel IEF with CBB staining. During DF IEF, the selected protein bands have been concentrated up to 16.8-fold.
650    _2
$a amfolytové směsi $7 D000665
650    _2
$a metody pro přípravu analytických vzorků $x přístrojové vybavení $x metody $7 D053000
650    _2
$a biologické přípravky $x chemie $x izolace a purifikace $7 D001688
650    _2
$a koncentrace vodíkových iontů $7 D006863
650    _2
$a isoelektrická fokusace $x přístrojové vybavení $x metody $7 D007525
650    _2
$a rostlinné extrakty $x chemie $x izolace a purifikace $7 D010936
650    _2
$a proteiny $x chemie $x izolace a purifikace $7 D011506
650    _2
$a pšenice $x chemie $7 D014908
650    _2
$a kvasinky $x chemie $7 D015003
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Šlais, Karel $7 xx0071057
773    0_
$w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 31, č. 3 (2010), s. 433-439
856    41
$u https://pubmed.ncbi.nlm.nih.gov/20119953 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120816 $b ABA008
991    __
$a 20130222224914 $b ABA008
999    __
$a ok $b bmc $g 947288 $s 782592
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 31 $c 3 $d 433-439 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
LZP    __
$a Pubmed-20120816/10/02

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...